메뉴 건너뛰기




Volumn 32, Issue 5, 2006, Pages 537-545

The utility of the PFA-100 in the identification of von Willebrand disease: A concise review

Author keywords

Bleeding disorders; Diagnosis; Laboratory assessment; PFA 100; Platelet function; Review; Von Willebrand disease; Von Willebrand disorder (vWD); Von Willebrand Factor (vWF)

Indexed keywords

ACETYLSALICYLIC ACID; DESMOPRESSIN;

EID: 33746650150     PISSN: 00946176     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2006-947869     Document Type: Review
Times cited : (72)

References (41)
  • 2
    • 0029034485 scopus 로고
    • Preliminary data from a field trial of the PFA-100® system
    • Mammen EF, Alshameeri RS, Comp PC. Preliminary data from a field trial of the PFA-100® system. Semin Thromb Hemost 1995;21(suppl 2):113-120
    • (1995) Semin Thromb Hemost , vol.21 , Issue.SUPPL. 2 , pp. 113-120
    • Mammen, E.F.1    Alshameeri, R.S.2    Comp, P.C.3
  • 3
    • 0034493564 scopus 로고    scopus 로고
    • Progress in the assessment of platelet function
    • Harrison P. Progress in the assessment of platelet function. Br J Haematol 2000;111:733-744
    • (2000) Br J Haematol , vol.111 , pp. 733-744
    • Harrison, P.1
  • 4
    • 0035080832 scopus 로고    scopus 로고
    • Utility of the PFA-100® for assessing bleeding disorders and monitoring therapy: A review of analytical variables, benefits and limitations
    • Favaloro EJ. Utility of the PFA-100® for assessing bleeding disorders and monitoring therapy: a review of analytical variables, benefits and limitations. Haemophilia 2001;7:170-179
    • (2001) Haemophilia , vol.7 , pp. 170-179
    • Favaloro, E.J.1
  • 5
    • 0034867946 scopus 로고    scopus 로고
    • Platelet function analyzer (PFA-100): A tool to quantify congenital or acquired platelet dysfunction
    • Jilma B. Platelet function analyzer (PFA-100): a tool to quantify congenital or acquired platelet dysfunction. J Lab Clin Med 2001;138:152-163
    • (2001) J Lab Clin Med , vol.138 , pp. 152-163
    • Jilma, B.1
  • 6
    • 22144455398 scopus 로고    scopus 로고
    • The role of PFA-100 testing in the investigation and management of haemostatic defects in children and adults
    • Harrison P. The role of PFA-100 testing in the investigation and management of haemostatic defects in children and adults. Br J Haematol 2005;130:3-10
    • (2005) Br J Haematol , vol.130 , pp. 3-10
    • Harrison, P.1
  • 7
    • 0036344893 scopus 로고    scopus 로고
    • Clinical utility of the PFA-100®
    • Favaloro EJ. Clinical utility of the PFA-100®. Curr Opin Hematol 2002;9:407-415
    • (2002) Curr Opin Hematol , vol.9 , pp. 407-415
    • Favaloro, E.J.1
  • 8
    • 0033502512 scopus 로고    scopus 로고
    • Laboratory assessment as a critical component of the appropriate diagnosis and sub-classification of von Willebrand's disease
    • Favaloro EJ. Laboratory assessment as a critical component of the appropriate diagnosis and sub-classification of von Willebrand's disease. Blood Rev 1999;13:185-204
    • (1999) Blood Rev , vol.13 , pp. 185-204
    • Favaloro, E.J.1
  • 9
    • 0034742637 scopus 로고    scopus 로고
    • Appropriate laboratory assessment as a critical facet in the proper diagnosis and classification of von Willebrand disorder
    • Favaloro EJ. Appropriate laboratory assessment as a critical facet in the proper diagnosis and classification of von Willebrand disorder. Best Pract Res Clin Haematol 2001;14:299-319
    • (2001) Best Pract Res Clin Haematol , vol.14 , pp. 299-319
    • Favaloro, E.J.1
  • 10
    • 33746602713 scopus 로고    scopus 로고
    • Laboratory identification of von Willebrand Disease: Technical and scientific perspectives
    • Favaloro EJ. Laboratory identification of von Willebrand Disease: technical and scientific perspectives. Semin Thromb Hemost 2006;32:456-471
    • (2006) Semin Thromb Hemost , vol.32 , pp. 456-471
    • Favaloro, E.J.1
  • 11
    • 0033785885 scopus 로고    scopus 로고
    • Diurnal variation in platelet aggregation with the PFA-100 platelet function analyser
    • Dalby MC, Davidson SJ, Burman JF, Davies SW. Diurnal variation in platelet aggregation with the PFA-100 platelet function analyser. Platelets 2000;11:320-324
    • (2000) Platelets , vol.11 , pp. 320-324
    • Dalby, M.C.1    Davidson, S.J.2    Burman, J.F.3    Davies, S.W.4
  • 12
    • 0036630534 scopus 로고    scopus 로고
    • Alterations in platelet function during the ovarian cycle
    • Feuring M, Christ M, Roell A, et al. Alterations in platelet function during the ovarian cycle. Blood Coagul Fibrinolysis 2002;13:443-447
    • (2002) Blood Coagul Fibrinolysis , vol.13 , pp. 443-447
    • Feuring, M.1    Christ, M.2    Roell, A.3
  • 13
    • 0035125905 scopus 로고    scopus 로고
    • Influence of the ABO blood type on the platelet function analyzer PFA-100
    • Lippi G, Franchini M, Brocco G, Manzato F. Influence of the ABO blood type on the platelet function analyzer PFA-100. Thromb Haemost 2001;85:369-370
    • (2001) Thromb Haemost , vol.85 , pp. 369-370
    • Lippi, G.1    Franchini, M.2    Brocco, G.3    Manzato, F.4
  • 15
    • 0037764713 scopus 로고    scopus 로고
    • The role of the platelet function analyser (PFA-100) in the characterization of patients with von Willebrand's disease and its relationships with von Willebrand factor and the ABO blood group
    • Nitu-Whalley IC, Lee CA, Brown SA, Riddell A, Hermans C. The role of the platelet function analyser (PFA-100) in the characterization of patients with von Willebrand's disease and its relationships with von Willebrand factor and the ABO blood group. Haemophilia 2003;9:298-302
    • (2003) Haemophilia , vol.9 , pp. 298-302
    • Nitu-Whalley, I.C.1    Lee, C.A.2    Brown, S.A.3    Riddell, A.4    Hermans, C.5
  • 16
    • 7144227947 scopus 로고    scopus 로고
    • The Platelet Function Analyzer (PFA-100): A novel in-vitro system for evaluation of primary haemostasis in children
    • Carcao MD, Blanchette VS, Dean JA, et al. The Platelet Function Analyzer (PFA-100): a novel in-vitro system for evaluation of primary haemostasis in children. Br J Haematol 1998;101:70-73
    • (1998) Br J Haematol , vol.101 , pp. 70-73
    • Carcao, M.D.1    Blanchette, V.S.2    Dean, J.A.3
  • 17
    • 0033828195 scopus 로고    scopus 로고
    • Von Willebrand Disease in a paediatric-based population-comparison of type 1 diagnostic criteria and use of the PFA-100® and a von Willebrand factor/collagen-binding assay
    • Dean JA, Blanchette VS, Carcao MD, et al. von Willebrand Disease in a paediatric-based population-comparison of type 1 diagnostic criteria and use of the PFA-100® and a von Willebrand factor/collagen-binding assay. Thromb Haemost 2000;84:401-409
    • (2000) Thromb Haemost , vol.84 , pp. 401-409
    • Dean, J.A.1    Blanchette, V.S.2    Carcao, M.D.3
  • 18
    • 0032519496 scopus 로고    scopus 로고
    • Screening for von Willebrand disease with a new analyzer using high shear stress: A study of 60 cases
    • Fressinaud E, Veyradier A, Truchaud F, et al. Screening for von Willebrand disease with a new analyzer using high shear stress: a study of 60 cases. Blood 1998;91:1325-1331
    • (1998) Blood , vol.91 , pp. 1325-1331
    • Fressinaud, E.1    Veyradier, A.2    Truchaud, F.3
  • 19
    • 0032878391 scopus 로고    scopus 로고
    • Therapeutic monitoring of von Willebrand disease: Interest and limits of a platelet function analyser at high shear rates
    • Fressinaud E, Veyradier A, Sigaud M, Boyer-Neumann C, Le Boterff C, Meyer D. Therapeutic monitoring of von Willebrand disease: interest and limits of a platelet function analyser at high shear rates. Br J Haematol 1999;106:777-783
    • (1999) Br J Haematol , vol.106 , pp. 777-783
    • Fressinaud, E.1    Veyradier, A.2    Sigaud, M.3    Boyer-Neumann, C.4    Le Boterff, C.5    Meyer, D.6
  • 20
    • 0031596559 scopus 로고    scopus 로고
    • PFA-100 system: A new method for assessment of platelet dysfunction
    • Mammen EF, Comp PC, Gosselin R, et al. PFA-100 system: a new method for assessment of platelet dysfunction. Semin Thromb Hemost 1998;24:195-202
    • (1998) Semin Thromb Hemost , vol.24 , pp. 195-202
    • Mammen, E.F.1    Comp, P.C.2    Gosselin, R.3
  • 21
    • 0032773694 scopus 로고    scopus 로고
    • Evaluation of the PFA-100 system in the diagnosis and therapeutic monitoring of patients with von Willebrand disease
    • Cattaneo M, Federici AB, Lecchi A, et al. Evaluation of the PFA-100 system in the diagnosis and therapeutic monitoring of patients with von Willebrand disease. Thromb Haemost 1999;82:35-39
    • (1999) Thromb Haemost , vol.82 , pp. 35-39
    • Cattaneo, M.1    Federici, A.B.2    Lecchi, A.3
  • 22
    • 0032712889 scopus 로고    scopus 로고
    • Use of a novel platelet function analyzer (PFA-100) with high sensitivity to disturbances in von Willebrand factor to screen for von Willebrand's disease and other disorders
    • Favaloro EJ, Facey D, Henniker A. Use of a novel platelet function analyzer (PFA-100) with high sensitivity to disturbances in von Willebrand factor to screen for von Willebrand's disease and other disorders. Am J Hematol 1999;62:165-174
    • (1999) Am J Hematol , vol.62 , pp. 165-174
    • Favaloro, E.J.1    Facey, D.2    Henniker, A.3
  • 23
    • 0035081481 scopus 로고    scopus 로고
    • Laboratory diagnosis of von Willebrand disorder (VWD) and monitoring of DDAVP therapy, efficacy of the PFA-100® and VWF:CBA as combined diagnostic strategies
    • Favaloro EJ, Kershaw G, Bukuya M, Hertzberg M, Koutts J. Laboratory diagnosis of von Willebrand disorder (VWD) and monitoring of DDAVP therapy, efficacy of the PFA-100® and VWF:CBA as combined diagnostic strategies. Haemophilia 2001;7:180-189
    • (2001) Haemophilia , vol.7 , pp. 180-189
    • Favaloro, E.J.1    Kershaw, G.2    Bukuya, M.3    Hertzberg, M.4    Koutts, J.5
  • 24
    • 13244278087 scopus 로고    scopus 로고
    • Template bleeding time and PFA-100 have low sensitivity to screen patients with hereditary mucocutaneous hemorrhages: Comparative study of 148 patients-a rebuttal
    • Favaloro EJ. Template bleeding time and PFA-100 have low sensitivity to screen patients with hereditary mucocutaneous hemorrhages: comparative study of 148 patients-a rebuttal. J Thromb Haemost 2004;2:2280-2282
    • (2004) J Thromb Haemost , vol.2 , pp. 2280-2282
    • Favaloro, E.J.1
  • 25
    • 0032919477 scopus 로고    scopus 로고
    • Performance of the platelet function analyser PFA-100 in testing abnormalities of primary haemostasis
    • Harrison P, Robinson MS, Mackie IJ, et al. Performance of the platelet function analyser PFA-100 in testing abnormalities of primary haemostasis. Blood Coagul Fibrinolysis 1999; 10:25-31
    • (1999) Blood Coagul Fibrinolysis , vol.10 , pp. 25-31
    • Harrison, P.1    Robinson, M.S.2    Mackie, I.J.3
  • 26
    • 0036373052 scopus 로고    scopus 로고
    • The PFA-100: A potential rapid screening tool for the assessment of platelet dysfunction
    • Harrison P, Robinson M, Liesner R, et al. The PFA-100: a potential rapid screening tool for the assessment of platelet dysfunction. Clin Lab Haematol 2002;24:225-232
    • (2002) Clin Lab Haematol , vol.24 , pp. 225-232
    • Harrison, P.1    Robinson, M.2    Liesner, R.3
  • 27
    • 0345581410 scopus 로고    scopus 로고
    • Comparison of PFA-100 closure time and template bleeding time of patients with inherited disorders causing defective platelet function
    • Kerenyi A, Schlammadinger A, Ajzner E, et al. Comparison of PFA-100 closure time and template bleeding time of patients with inherited disorders causing defective platelet function. Thromb Res 1999;96:487-492
    • (1999) Thromb Res , vol.96 , pp. 487-492
    • Kerenyi, A.1    Schlammadinger, A.2    Ajzner, E.3
  • 28
    • 0033935043 scopus 로고    scopus 로고
    • Comparison of the O'Brien filter test and the PFA-100 platelet analyser in the laboratory diagnosis of von Willebrand's disease
    • Schlammadinger A, Kerenyi A, Muszbek L, Boda Z. Comparison of the O'Brien filter test and the PFA-100 platelet analyser in the laboratory diagnosis of von Willebrand's disease. Thromb Haemost 2000;84:88-92
    • (2000) Thromb Haemost , vol.84 , pp. 88-92
    • Schlammadinger, A.1    Kerenyi, A.2    Muszbek, L.3    Boda, Z.4
  • 29
    • 0032836976 scopus 로고    scopus 로고
    • The platelet function analyzer (PFA-100) may not be suitable for monitoring the therapeutic efficiency of von Willebrand concentrate in type III von Willebrand disease
    • Meskal A, Vertessen F, Van der Planken M, Berneman ZN. The platelet function analyzer (PFA-100) may not be suitable for monitoring the therapeutic efficiency of von Willebrand concentrate in type III von Willebrand disease. Ann Hematol 1999;78:426-430
    • (1999) Ann Hematol , vol.78 , pp. 426-430
    • Meskal, A.1    Vertessen, F.2    Van Der Planken, M.3    Berneman, Z.N.4
  • 31
    • 0036592728 scopus 로고    scopus 로고
    • Rational use of the PFA-100 device for screening of platelet function disorders and von Willebrand disease
    • Buyukasik Y, Karakus S, Goker H, et al. Rational use of the PFA-100 device for screening of platelet function disorders and von Willebrand disease. Blood Coagul Fibrinolysis 2002; 13:349-353
    • (2002) Blood Coagul Fibrinolysis , vol.13 , pp. 349-353
    • Buyukasik, Y.1    Karakus, S.2    Goker, H.3
  • 32
    • 0037055911 scopus 로고    scopus 로고
    • Evaluation of a Platelet Function Analyser (PFA-100) in patients with a bleeding tendency
    • Wuillemin WA, Gasser KM, Zeerleder SS, Lammle B. Evaluation of a Platelet Function Analyser (PFA-100) in patients with a bleeding tendency. Swiss Med Wkly 2002; 132:443-448
    • (2002) Swiss Med Wkly , vol.132 , pp. 443-448
    • Wuillemin, W.A.1    Gasser, K.M.2    Zeerleder, S.S.3    Lammle, B.4
  • 33
    • 0038616078 scopus 로고    scopus 로고
    • Comparison of PFA-100 and bleeding time testing in pediatric patients with suspected hemorrhagic problems
    • Cariappa R, Wilhite TR, Parvin CA, Luchtman-Jones L. Comparison of PFA-100 and bleeding time testing in pediatric patients with suspected hemorrhagic problems. J Pediatr Hematol Oncol 2003;25:474-479
    • (2003) J Pediatr Hematol Oncol , vol.25 , pp. 474-479
    • Cariappa, R.1    Wilhite, T.R.2    Parvin, C.A.3    Luchtman-Jones, L.4
  • 34
    • 0141428992 scopus 로고    scopus 로고
    • Comparison of PFA-100 testing and bleeding time for detecting platelet hypofunction and von Willebrand disease in clinical practice
    • Posan E, McBane RD, Grill DE, Motsko CL, Nichols WL. Comparison of PFA-100 testing and bleeding time for detecting platelet hypofunction and von Willebrand disease in clinical practice. Thromb Haemost 2003;90:483-490
    • (2003) Thromb Haemost , vol.90 , pp. 483-490
    • Posan, E.1    McBane, R.D.2    Grill, D.E.3    Motsko, C.L.4    Nichols, W.L.5
  • 35
    • 13244279572 scopus 로고    scopus 로고
    • Template bleeding time and PFA-100 have low sensitivity to screen patients with hereditary mucocutaneous hemorrhages: Comparative study in 148 patients
    • Quiroga T, Goycoolea M, Munoz B, et al. Template bleeding time and PFA-100 have low sensitivity to screen patients with hereditary mucocutaneous hemorrhages: comparative study in 148 patients. J Thromb Haemost 2004;2: 892-898
    • (2004) J Thromb Haemost , vol.2 , pp. 892-898
    • Quiroga, T.1    Goycoolea, M.2    Munoz, B.3
  • 36
    • 28444474829 scopus 로고    scopus 로고
    • Reassessment of ABO-blood group, gender and age on laboratory parameters used to diagnose von Willebrand Disorder (VWD): Potential influence on the diagnosis versus the potential association with risk of thrombosis
    • Favaloro EJ, Soltani S, McDonald J, Grezchnik E, Easton L, Favaloro JWC. Reassessment of ABO-blood group, gender and age on laboratory parameters used to diagnose von Willebrand Disorder (VWD): potential influence on the diagnosis versus the potential association with risk of thrombosis. Am J Clin Pathol 2005;124:910-917
    • (2005) Am J Clin Pathol , vol.124 , pp. 910-917
    • Favaloro, E.J.1    Soltani, S.2    McDonald, J.3    Grezchnik, E.4    Easton, L.5    Favaloro, J.W.C.6
  • 37
    • 0036281805 scopus 로고    scopus 로고
    • Evaluation of the PFA-100 system for monitoring desmopressin therapy in patients with type 1 von Willebrand's disease
    • Franchini M, Gandini G, Manzato F, Lippi G. Evaluation of the PFA-100 system for monitoring desmopressin therapy in patients with type 1 von Willebrand's disease. Haematologica 2002;87:670
    • (2002) Haematologica , vol.87 , pp. 670
    • Franchini, M.1    Gandini, G.2    Manzato, F.3    Lippi, G.4
  • 38
    • 0032959927 scopus 로고    scopus 로고
    • Can the platelet function analyser (PFA)-100 test substitute for the template bleeding time in routine clinical practice
    • Francis JL, Francis D, Larson L, Helms E, Garcia M. Can the platelet function analyser (PFA)-100 test substitute for the template bleeding time in routine clinical practice. Platelets 1999;10:132-136
    • (1999) Platelets , vol.10 , pp. 132-136
    • Francis, J.L.1    Francis, D.2    Larson, L.3    Helms, E.4    Garcia, M.5
  • 39
    • 0036234931 scopus 로고    scopus 로고
    • Von Willebrand factor (VWF) collagen binding (activity) assay (VWF:CBA) in the diagnosis of von Willebrand's disorder (VWD): A 15-year journey
    • Favaloro EJ. von Willebrand factor (VWF) collagen binding (activity) assay (VWF:CBA) in the diagnosis of von Willebrand's disorder (VWD): a 15-year journey. Semin Thromb Hemost 2002;28:191-202
    • (2002) Semin Thromb Hemost , vol.28 , pp. 191-202
    • Favaloro, E.J.1
  • 40
    • 27244434958 scopus 로고    scopus 로고
    • Variables influencing Platelet Function Analyzer-100 closure times in healthy individuals
    • Haubelt H, Anders C, Vogt A, Hoerdt P, Seyfert UT, Hellstern P. Variables influencing Platelet Function Analyzer-100 closure times in healthy individuals. Br J Haematol 2005;130:759-767
    • (2005) Br J Haematol , vol.130 , pp. 759-767
    • Haubelt, H.1    Anders, C.2    Vogt, A.3    Hoerdt, P.4    Seyfert, U.T.5    Hellstern, P.6
  • 41
    • 13244251165 scopus 로고    scopus 로고
    • Are the bleeding time and PFA-100 useful in the initial screening of patients with mucocutaneous bleedings of hereditary nature?
    • Cattaneo M. Are the bleeding time and PFA-100 useful in the initial screening of patients with mucocutaneous bleedings of hereditary nature? J Thromb Haemost 2004;2:890-891
    • (2004) J Thromb Haemost , vol.2 , pp. 890-891
    • Cattaneo, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.