-
2
-
-
33646934641
-
Glaucoma drainage implants: A critical comparison of types
-
Schwartz KS, Lee RK, Gedde SJ. Glaucoma drainage implants: a critical comparison of types. Curr Opin Ophthalmol 2006;17:181-89
-
(2006)
Curr Opin Ophthalmol
, vol.17
, pp. 181-189
-
-
Schwartz, K.S.1
Lee, R.K.2
Gedde, S.J.3
-
3
-
-
0035116201
-
Clinical evaluation and risk factors of time to failure of Ahmed glaucoma valve implant in pediatric patients
-
Djodeyre MR, Peralta-Calvo J, Abelairas-Gomez J. Clinical evaluation and risk factors of time to failure of Ahmed glaucoma valve implant in pediatric patients. Ophthalmology 2001;108:614-20
-
(2001)
Ophthalmology
, vol.108
, pp. 614-620
-
-
Djodeyre, M.R.1
Peralta-Calvo, J.2
Abelairas-Gomez, J.3
-
4
-
-
0033949045
-
Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma
-
Lai JS, Poon AS, Chua JK, et al. Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma. Br J Ophthalmol 2000;84:718-21
-
(2000)
Br J Ophthalmol
, vol.84
, pp. 718-721
-
-
Lai, J.S.1
Poon, A.S.2
Chua, J.K.3
-
5
-
-
0029044910
-
Initial clinical experience with the Ahmed glaucoma valve implant
-
Coleman AL, Hill R, Wilson MR, et al. Initial clinical experience with the Ahmed glaucoma valve implant. Am J Ophthalmol 1995;120:23-31
-
(1995)
Am J Ophthalmol
, vol.120
, pp. 23-31
-
-
Coleman, A.L.1
Hill, R.2
Wilson, M.R.3
-
7
-
-
0035156593
-
Traumatic glaucoma
-
Hitchings R. Traumatic glaucoma. J Glaucoma 2001;10:436-39
-
(2001)
J Glaucoma
, vol.10
, pp. 436-439
-
-
Hitchings, R.1
-
9
-
-
34648860056
-
Intermediate-term and long-term clinical evaluation of the Ahmed glaucoma valve implantation
-
Chen H, Zhang SX, Liu L, et al. Intermediate-term and long-term clinical evaluation of the Ahmed glaucoma valve implantation. Zhonghua Yan Ke Za Zhi 2005;41:796-802
-
(2005)
Zhonghua Yan Ke Za Zhi
, vol.41
, pp. 796-802
-
-
Chen, H.1
Zhang, S.X.2
Liu, L.3
-
10
-
-
0035023320
-
Anatomic and histopathologic findings following a failed Ahmed glaucoma valve device
-
Ayyala RS, Layden WE, Slonim CB, et al. Anatomic and histopathologic findings following a failed Ahmed glaucoma valve device. Ophthalmic Surg Lasers 2001;32:248-49
-
(2001)
Ophthalmic Surg Lasers
, vol.32
, pp. 248-249
-
-
Ayyala, R.S.1
Layden, W.E.2
Slonim, C.B.3
-
11
-
-
22544454729
-
Incidence and management of encapsulated cysts following Ahmed glaucoma valve insertion
-
Eibschitz-Tsimhoni M, Schertzer RM, Musch DC, et al. Incidence and management of encapsulated cysts following Ahmed glaucoma valve insertion. J Glaucoma 2005;14:276-79
-
(2005)
J Glaucoma
, vol.14
, pp. 276-279
-
-
Eibschitz-Tsimhoni, M.1
Schertzer, R.M.2
Musch, D.C.3
-
12
-
-
11144283166
-
Glaucoma drainage devices: A systematic literature review and current controversies
-
Hong CH, Arosemena A, Zurakowski D, et al. Glaucoma drainage devices: a systematic literature review and current controversies. Surv Ophthalmol 2005;50:48-60
-
(2005)
Surv Ophthalmol
, vol.50
, pp. 48-60
-
-
Hong, C.H.1
Arosemena, A.2
Zurakowski, D.3
-
13
-
-
0041429360
-
The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma: A single-surgeon comparison of outcome
-
Tsai JC, Johnson CC, Dietrich MS. The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma: a single-surgeon comparison of outcome. Ophthalmology 2003;110:1814-21
-
(2003)
Ophthalmology
, vol.110
, pp. 1814-1821
-
-
Tsai, J.C.1
Johnson, C.C.2
Dietrich, M.S.3
-
14
-
-
0033901338
-
Comparison of different biomaterials for glaucoma drainage devices: Part 2
-
Ayyala RS, Michelini-Norris B, Flores A, et al. Comparison of different biomaterials for glaucoma drainage devices: part 2. Arch Ophthalmol 2000;118:1081-84
-
(2000)
Arch Ophthalmol
, vol.118
, pp. 1081-1084
-
-
Ayyala, R.S.1
Michelini-Norris, B.2
Flores, A.3
|