Appropriate diameter for screws to fix the maxilla following Le Fort I osteotomy: An investigation utilizing finite element analysis

Author keywords

Le Fort I, maxilla, osteotomy, fixation, screw

Indexed keywords

ARTICLE; BIOMECHANICS; BONE PLATE; BONE SCREW; CALCULATION; COMPUTER AIDED DESIGN; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER MODEL; COMPUTER SIMULATION; CONTROLLED STUDY; FINITE ELEMENT ANALYSIS; FRACTURE FIXATION; MAXILLA OSTEOTOMY; TENSILE STRENGTH; THREE DIMENSIONAL IMAGING;

EID: 34548654327     PISSN: 10105182     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcms.2007.04.009     Document Type: Article
Times cited : (15)

References (26)
  • 1
    • 1242336791 scopus 로고    scopus 로고
    • Role of aortic root motion in the pathogenesis of aortic dissection
    • Beller C.J., Labrosse M.R., Thubrikar M.J., and Robicsek F. Role of aortic root motion in the pathogenesis of aortic dissection. Circulation 109 (2004) 763-769
    • (2004) Circulation , vol.109 , pp. 763-769
    • Beller, C.J.1    Labrosse, M.R.2    Thubrikar, M.J.3    Robicsek, F.4
  • 2
    • 0025294481 scopus 로고
    • Zygomatic fractures: comparison of methods of internal fixation
    • Davidson J., Nickerson D., and Nickerson B. Zygomatic fractures: comparison of methods of internal fixation. Plast Reconstr Surg 86 (1990) 25-32
    • (1990) Plast Reconstr Surg , vol.86 , pp. 25-32
    • Davidson, J.1    Nickerson, D.2    Nickerson, B.3
  • 3
    • 84995418889 scopus 로고    scopus 로고
    • Biomechanical analysis of the rigid fixation of zygoma fractures: an experimental study
    • Deveci M., Eski M., Gurse S., Yucesoy C., Selmanpakoglu N., and Akkas N. Biomechanical analysis of the rigid fixation of zygoma fractures: an experimental study. J Craniofac Surg 15 (2004) 595-602
    • (2004) J Craniofac Surg , vol.15 , pp. 595-602
    • Deveci, M.1    Eski, M.2    Gurse, S.3    Yucesoy, C.4    Selmanpakoglu, N.5    Akkas, N.6
  • 5
    • 0024623750 scopus 로고
    • Occlusal force pattern in dentitions with mandibular implant-supported fixed cantilever prostheses occluded with complete dentures
    • Falk H., Laurell L., and Lundgren D. Occlusal force pattern in dentitions with mandibular implant-supported fixed cantilever prostheses occluded with complete dentures. Int J Oral Maxillofac Implants 4 (1989) 55-62
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 55-62
    • Falk, H.1    Laurell, L.2    Lundgren, D.3
  • 6
    • 14944366977 scopus 로고    scopus 로고
    • Figueroa AA, Polly JW, Friede H, Ko EW: Long-term skeletal stability after maxillary advancement with distraction osteogenesis using a rigid external distraction device in cleft maxillary deformities. Plast Reconstr Surg 114: 1382-1392; discussion 1393-1394, 2004
  • 7
    • 0005327916 scopus 로고    scopus 로고
    • Dynamic analysis of osseointegrated implants on edentulous mandible by three dimensional finite element method: Effect of fixture number and length on the stress distribution around the implants
    • Hanai J. Dynamic analysis of osseointegrated implants on edentulous mandible by three dimensional finite element method: Effect of fixture number and length on the stress distribution around the implants. Shikwa Gakuho 98 (1998) 933-954
    • (1998) Shikwa Gakuho , vol.98 , pp. 933-954
    • Hanai, J.1
  • 8
    • 20544446222 scopus 로고    scopus 로고
    • Relapse after orthodontics and orthognathic surgery
    • Haralabakis N., and Padadakis G. Relapse after orthodontics and orthognathic surgery. World J Orthod 6 (2005) 125-140
    • (2005) World J Orthod , vol.6 , pp. 125-140
    • Haralabakis, N.1    Padadakis, G.2
  • 9
    • 0021782967 scopus 로고
    • Masticatory muscle function in patients rehabilitated with oral implant bridges
    • Haraldson T. Masticatory muscle function in patients rehabilitated with oral implant bridges. Swed Dent J 28 (1985) 137-142
    • (1985) Swed Dent J , vol.28 , pp. 137-142
    • Haraldson, T.1
  • 10
    • 0017613222 scopus 로고
    • Bite force and oral function in patients with osseointegrated oral implants
    • Haraldson T., and Carlsson G.E. Bite force and oral function in patients with osseointegrated oral implants. Scand J Dent Res 85 (1977) 200-208
    • (1977) Scand J Dent Res , vol.85 , pp. 200-208
    • Haraldson, T.1    Carlsson, G.E.2
  • 11
    • 0035026802 scopus 로고    scopus 로고
    • Factors related to relapse after LeFort 1 maxillary advancement osteotomy in patients with cleft lip and palate
    • Hirano A., and Suzuki H. Factors related to relapse after LeFort 1 maxillary advancement osteotomy in patients with cleft lip and palate. Cleft Palate Craniofac J 38 (2001) 1-10
    • (2001) Cleft Palate Craniofac J , vol.38 , pp. 1-10
    • Hirano, A.1    Suzuki, H.2
  • 12
    • 2442594770 scopus 로고    scopus 로고
    • The skeletal stability of one piece LeFort 1 osteotomy to advance the maxilla; Part1: Stability resulting from non-bone grafted rigid fixation
    • Hoffman G.R., and Brennan P.A. The skeletal stability of one piece LeFort 1 osteotomy to advance the maxilla; Part1: Stability resulting from non-bone grafted rigid fixation. Br J Oral Maxillofac Surg 42 (2004) 221-225
    • (2004) Br J Oral Maxillofac Surg , vol.42 , pp. 221-225
    • Hoffman, G.R.1    Brennan, P.A.2
  • 13
    • 0033857339 scopus 로고    scopus 로고
    • Can dog-ear formation be decreased when an S-shaped skin resection is used instead of a spindle skin resection? A three-dimensional analysis of skin surgery techniques using the finite element method
    • Mizunuma M., Yanai A., Tsutsumi S., Yoshida H., Inoue M., and Nishida M. Can dog-ear formation be decreased when an S-shaped skin resection is used instead of a spindle skin resection? A three-dimensional analysis of skin surgery techniques using the finite element method. Plast Reconst Surg 106 (2000) 845-848
    • (2000) Plast Reconst Surg , vol.106 , pp. 845-848
    • Mizunuma, M.1    Yanai, A.2    Tsutsumi, S.3    Yoshida, H.4    Inoue, M.5    Nishida, M.6
  • 14
    • 0038416059 scopus 로고    scopus 로고
    • Comparison of the postsurgical stability of the Le Fort 1 osteotomy using 2- and 4-plate fixation
    • Murray R.A., Upton L.G., and Rottman K.R. Comparison of the postsurgical stability of the Le Fort 1 osteotomy using 2- and 4-plate fixation. J Oral Maxillofac Surg 61 (2003) 574-579
    • (2003) J Oral Maxillofac Surg , vol.61 , pp. 574-579
    • Murray, R.A.1    Upton, L.G.2    Rottman, K.R.3
  • 15
    • 0036592503 scopus 로고    scopus 로고
    • Finite elements analysis of the stresses around fixtures in various reconstructed mandibular models
    • Nagasao T., Kobayashi M., Tsuchiya Y., Kaneko T., and Nakajima T. Finite elements analysis of the stresses around fixtures in various reconstructed mandibular models. J Cranio-Maxillofac Surg 30 (2002) 170-177
    • (2002) J Cranio-Maxillofac Surg , vol.30 , pp. 170-177
    • Nagasao, T.1    Kobayashi, M.2    Tsuchiya, Y.3    Kaneko, T.4    Nakajima, T.5
  • 16
    • 0038158252 scopus 로고    scopus 로고
    • Finite element analysis of the stresses around fixtures in various reconstructed mandibular models - Part II (effect of horizontal load)
    • Nagasao T., Kobayashi M., Tsuchiya Y., Kaneko T., and Nakajima T. Finite element analysis of the stresses around fixtures in various reconstructed mandibular models - Part II (effect of horizontal load). J Cranio-Maxillofac Surg 31 (2003) 168-175
    • (2003) J Cranio-Maxillofac Surg , vol.31 , pp. 168-175
    • Nagasao, T.1    Kobayashi, M.2    Tsuchiya, Y.3    Kaneko, T.4    Nakajima, T.5
  • 17
    • 16844363499 scopus 로고    scopus 로고
    • Nagasao T, Nakajima T, Kimura N, Kaneko T, Jin H, Tamaki T: The dynamic role of buttress reconstruction after maxillectomy. Plast Reconst Surg 115: 1328-1340; discussion 1341, 2005
  • 19
    • 33748335448 scopus 로고    scopus 로고
    • Nagasao T, Miyamoto J, Nagasao M, Ogata H, Kaneko T, Tamaki T, Nakajima T: The effect of striking angle on the buckling mechanism in blowout fracture. Plast Reconst Surg 117: 2373-2380; discussion 2381, 2006b
  • 20
    • 2342536354 scopus 로고    scopus 로고
    • Le Fort 1 miniplate osteosynthesis: a randomized, prospective study comparing restorable PLLA/PGA with titanium
    • Norholt S.E., Bierregaard J., and Mosekilde I. Le Fort 1 miniplate osteosynthesis: a randomized, prospective study comparing restorable PLLA/PGA with titanium. Int J Maxillofac Surg 33 (2004) 245-252
    • (2004) Int J Maxillofac Surg , vol.33 , pp. 245-252
    • Norholt, S.E.1    Bierregaard, J.2    Mosekilde, I.3
  • 21
    • 0030071137 scopus 로고    scopus 로고
    • O'Hara DE, DelVecchio DA, Barlett SP, Whitaker LA: The role of microfixation in malar fractures: a quantitative biophysical study. Plast Reconstr Surg 97: 345-350; discussion 351-353, 1996
  • 22
    • 0344699356 scopus 로고    scopus 로고
    • Pre-surgical CT/FEA for craniofacial distraction, I: methodology, development, and validation of the cranial finite element model
    • Remmler D., Olson L., Ekstrom R., Duke D., Matthews D., and Ulrich C.G. Pre-surgical CT/FEA for craniofacial distraction, I: methodology, development, and validation of the cranial finite element model. Med Eng Phys 20 (1998) 607-619
    • (1998) Med Eng Phys , vol.20 , pp. 607-619
    • Remmler, D.1    Olson, L.2    Ekstrom, R.3    Duke, D.4    Matthews, D.5    Ulrich, C.G.6
  • 24
    • 0036839534 scopus 로고    scopus 로고
    • The sphenozygomatic suture as a key site for osteosynthesis of the orbitozygomatic complex in panfacial fractures: a biomechanical study in human cadavers based on clinical practice
    • Rohner D., Tay A., Chung S., Hutmacher D.W., and Hammer B. The sphenozygomatic suture as a key site for osteosynthesis of the orbitozygomatic complex in panfacial fractures: a biomechanical study in human cadavers based on clinical practice. Plast Reconst Surg 110 (2002) 1463-1471
    • (2002) Plast Reconst Surg , vol.110 , pp. 1463-1471
    • Rohner, D.1    Tay, A.2    Chung, S.3    Hutmacher, D.W.4    Hammer, B.5
  • 25
    • 7644241840 scopus 로고    scopus 로고
    • Magnitude and role of wall shear stress on cerebral aneurysm: computational fluid dynamic study of 20 middle cerebral artery aneurysms
    • Shojima M., Oshima M., Takagi K., Torii R., Hayakawa M., Katada K., Morita A., and Kirino T. Magnitude and role of wall shear stress on cerebral aneurysm: computational fluid dynamic study of 20 middle cerebral artery aneurysms. Stroke 35 (2004) 2500-2505
    • (2004) Stroke , vol.35 , pp. 2500-2505
    • Shojima, M.1    Oshima, M.2    Takagi, K.3    Torii, R.4    Hayakawa, M.5    Katada, K.6    Morita, A.7    Kirino, T.8
  • 26
    • 29144449965 scopus 로고    scopus 로고
    • Maxillary stability following Le Fort 1 osteotomy in combination with sagittal split ramus osteotomy and intraoral vertical ramus osteotomy: a comparative study between titanium miniplate and poly-l-lactic acid plate
    • Ueki K., Maruyama K., Shimada M., Nakagawa K., Alam S., and Yamamoto E. Maxillary stability following Le Fort 1 osteotomy in combination with sagittal split ramus osteotomy and intraoral vertical ramus osteotomy: a comparative study between titanium miniplate and poly-l-lactic acid plate. J Oral Maxillofac Surg 64 (2006) 74-80
    • (2006) J Oral Maxillofac Surg , vol.64 , pp. 74-80
    • Ueki, K.1    Maruyama, K.2    Shimada, M.3    Nakagawa, K.4    Alam, S.5    Yamamoto, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.