메뉴 건너뛰기




Volumn 3, Issue 6, 2007, Pages 1041-1049

Bioreactor design for cornea tissue engineering: Material-cell interactions

Author keywords

Corneal stromal fibroblasts; Polyetheretherketone; Polyoxymethylene copolymer; Polyoxymethylene homopolymer; UHMWPE

Indexed keywords

ACETAL RESINS; ALUMINUM ALLOYS; ASTM STANDARDS; BIOCONVERSION; BIOREACTORS; CELL ENGINEERING; FIBROBLASTS; TISSUE; TISSUE ENGINEERING;

EID: 34548534586     PISSN: 17427061     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.actbio.2007.04.008     Document Type: Article
Times cited : (13)

References (25)
  • 1
    • 3142600686 scopus 로고    scopus 로고
    • Cornea recipients: are their opinions and attitudes toward organ donation different from those of the general population?
    • Abuksis G., et al. Cornea recipients: are their opinions and attitudes toward organ donation different from those of the general population?. Transplant Proc 36 (2004) 1249
    • (2004) Transplant Proc , vol.36 , pp. 1249
    • Abuksis, G.1
  • 3
    • 70449138788 scopus 로고
    • The structure and transparency of the cornea
    • Maurice D.M. The structure and transparency of the cornea. J Phys 136 (1957) 263-268
    • (1957) J Phys , vol.136 , pp. 263-268
    • Maurice, D.M.1
  • 4
    • 0043013300 scopus 로고    scopus 로고
    • Biomechanical and optical characteristics of a corneal stromal equivalent
    • Orwin E.J., Borene M.L., and Hubel A. Biomechanical and optical characteristics of a corneal stromal equivalent. J Biomech Eng 125 (2003) 1-6
    • (2003) J Biomech Eng , vol.125 , pp. 1-6
    • Orwin, E.J.1    Borene, M.L.2    Hubel, A.3
  • 6
    • 1642563967 scopus 로고    scopus 로고
    • The role of bioreactors in tissue engineering
    • Martin I., Wendt D., and Herber M. The role of bioreactors in tissue engineering. Trends Biotechnol 22 2 (2004) 80-86
    • (2004) Trends Biotechnol , vol.22 , Issue.2 , pp. 80-86
    • Martin, I.1    Wendt, D.2    Herber, M.3
  • 7
    • 0021229670 scopus 로고
    • Effect of steam sterilization on polyethylene terephthalate
    • Nair P.D., and Sreenivasan K. Effect of steam sterilization on polyethylene terephthalate. Biomaterials 5 (1984) 305
    • (1984) Biomaterials , vol.5 , pp. 305
    • Nair, P.D.1    Sreenivasan, K.2
  • 8
    • 0020781302 scopus 로고
    • Biocompatibility test procedures for materials evaluation in vitro I. Comparative test system sensitivity
    • Johnson H.J., Northup S.J., Seagraves P.A., Garvin P.J., and Wallin R.F. Biocompatibility test procedures for materials evaluation in vitro I. Comparative test system sensitivity. J Biomed Mater Res 17 (1983) 571
    • (1983) J Biomed Mater Res , vol.17 , pp. 571
    • Johnson, H.J.1    Northup, S.J.2    Seagraves, P.A.3    Garvin, P.J.4    Wallin, R.F.5
  • 9
    • 0027571719 scopus 로고
    • Biocompatibility of polyoxymethylene (Delrin) in bone
    • Ohlin A., and Linder L. Biocompatibility of polyoxymethylene (Delrin) in bone. Biomaterials 14 4 (1992) 285-289
    • (1992) Biomaterials , vol.14 , Issue.4 , pp. 285-289
    • Ohlin, A.1    Linder, L.2
  • 10
    • 0030111456 scopus 로고    scopus 로고
    • Evaluation of the effect of three surface treatments on the biocompatibility of 316L stainless steel using human differentiated cells
    • Bordji K., Jouzeau J.Y., Mainard D., Payan E., Delagoutte J.P., and Netter P. Evaluation of the effect of three surface treatments on the biocompatibility of 316L stainless steel using human differentiated cells. Biomaterials 17 (1996) 491
    • (1996) Biomaterials , vol.17 , pp. 491
    • Bordji, K.1    Jouzeau, J.Y.2    Mainard, D.3    Payan, E.4    Delagoutte, J.P.5    Netter, P.6
  • 11
    • 24744462097 scopus 로고    scopus 로고
    • Performance of polyoxymethylene plastic (POM) as a component of a tissue engineering bioreactor
    • Penick K.J., Solchaga L.A., Berilla J.A., and Welter J.F. Performance of polyoxymethylene plastic (POM) as a component of a tissue engineering bioreactor. J Biomed Mater Res A 75 1 (2005) 168-174
    • (2005) J Biomed Mater Res A , vol.75 , Issue.1 , pp. 168-174
    • Penick, K.J.1    Solchaga, L.A.2    Berilla, J.A.3    Welter, J.F.4
  • 12
    • 0016938497 scopus 로고
    • Biocompatibility of materials for total joint replacement
    • Escalas F., Galante J., and Rostoker W. Biocompatibility of materials for total joint replacement. J Biomed Mater Res 10 (1976) 175
    • (1976) J Biomed Mater Res , vol.10 , pp. 175
    • Escalas, F.1    Galante, J.2    Rostoker, W.3
  • 13
    • 0001990344 scopus 로고
    • Tissue reactions to polytetrafluoroethlyene
    • Charnley J. Tissue reactions to polytetrafluoroethlyene. Lancet 282 173 (1963) 1379
    • (1963) Lancet , vol.282 , Issue.173 , pp. 1379
    • Charnley, J.1
  • 14
    • 0027627674 scopus 로고
    • Polyimides as biomaterials: preliminary biocompatibility testing
    • Richardson R.R. Polyimides as biomaterials: preliminary biocompatibility testing. Biomaterials 14 (1993) 627
    • (1993) Biomaterials , vol.14 , pp. 627
    • Richardson, R.R.1
  • 15
    • 0033146243 scopus 로고    scopus 로고
    • Cytotoxicity of dental casting alloys pretreated with biologic solutions
    • Nelson S.K., Wataha J.C., and Lockwood P.E. Cytotoxicity of dental casting alloys pretreated with biologic solutions. J Prosthet Dent 81 (1999) 715
    • (1999) J Prosthet Dent , vol.81 , pp. 715
    • Nelson, S.K.1    Wataha, J.C.2    Lockwood, P.E.3
  • 17
    • 0031554866 scopus 로고    scopus 로고
    • Culture materials affect ex vivo expansion of hematopoietic progenitor cells
    • LaIuppa J.A., McAdams T.A., Papoutsakis E.T., and Miller W.M. Culture materials affect ex vivo expansion of hematopoietic progenitor cells. J Biomed Mater Res 36 3 (1997) 347-359
    • (1997) J Biomed Mater Res , vol.36 , Issue.3 , pp. 347-359
    • LaIuppa, J.A.1    McAdams, T.A.2    Papoutsakis, E.T.3    Miller, W.M.4
  • 18
    • 0029380344 scopus 로고
    • Currently practiced sterilization methods - some inadvertent consequences
    • Nair P.D. Currently practiced sterilization methods - some inadvertent consequences. J Biomater Appl 10 (1995) 121
    • (1995) J Biomater Appl , vol.10 , pp. 121
    • Nair, P.D.1
  • 19
    • 0030484525 scopus 로고    scopus 로고
    • Effects of multiple sterilization on surface characteristics and in vitro biologic responses to titanium
    • Vezeau P.J., Koorbusch G.F., Draughn R.A., and Keller J.C. Effects of multiple sterilization on surface characteristics and in vitro biologic responses to titanium. J Oral Maxillofac Surg 54 (1996) 738
    • (1996) J Oral Maxillofac Surg , vol.54 , pp. 738
    • Vezeau, P.J.1    Koorbusch, G.F.2    Draughn, R.A.3    Keller, J.C.4
  • 22
    • 0025111818 scopus 로고
    • New approaches for biocompatibility testing using cell culture
    • Doillon C.J., and Cameron K. New approaches for biocompatibility testing using cell culture. Int J Artif Organs 13 (1990) 517
    • (1990) Int J Artif Organs , vol.13 , pp. 517
    • Doillon, C.J.1    Cameron, K.2
  • 23
    • 0021326390 scopus 로고
    • Toxicity testing of medical device materials tested in human tissue cultures
    • Haustveit G., Torheim B., Fystro D., Eidem T., and Sandvik M. Toxicity testing of medical device materials tested in human tissue cultures. Biomaterials 5 (1984) 75
    • (1984) Biomaterials , vol.5 , pp. 75
    • Haustveit, G.1    Torheim, B.2    Fystro, D.3    Eidem, T.4    Sandvik, M.5
  • 24
    • 0033838678 scopus 로고    scopus 로고
    • In vitro culture characteristics of corneal epithelial, endothelial and keratocytes in a native collagen matrix
    • Orwin E.J., and Hubel A. In vitro culture characteristics of corneal epithelial, endothelial and keratocytes in a native collagen matrix. Tissue Eng 6 (2000) 307-319
    • (2000) Tissue Eng , vol.6 , pp. 307-319
    • Orwin, E.J.1    Hubel, A.2
  • 25
    • 0021061819 scopus 로고
    • Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays
    • Mosmann T. Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays. J Immunol Methods 16 (1983) 55
    • (1983) J Immunol Methods , vol.16 , pp. 55
    • Mosmann, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.