메뉴 건너뛰기




Volumn 188, Issue 1, 2007, Pages 68-73

Single loop multi-gap resonator for whole body EPR imaging of mice at 1.2 GHz

Author keywords

Electron paramagnetic resonance; Imaging; Resonator; Spectroscopy

Indexed keywords

FREQUENCY ESTIMATION; IMAGE ANALYSIS; MICROWAVES; PARAMAGNETIC RESONANCE;

EID: 34548485564     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2007.05.021     Document Type: Article
Times cited : (19)

References (32)
  • 1
    • 33846005859 scopus 로고    scopus 로고
    • Use of multi-coil parallel-gap resonators for co-registration EPR/NMR imaging
    • Kawada Y., Hirata H., and Fujii H. Use of multi-coil parallel-gap resonators for co-registration EPR/NMR imaging. J. Magn. Reson. 184 1 (2007) 29-38
    • (2007) J. Magn. Reson. , vol.184 , Issue.1 , pp. 29-38
    • Kawada, Y.1    Hirata, H.2    Fujii, H.3
  • 2
    • 0036187542 scopus 로고    scopus 로고
    • EPR/NMR co-imaging for anatomic registration of free-radical images
    • He G., Deng Y., Li H., Kuppusamy P., and Zweier J.L. EPR/NMR co-imaging for anatomic registration of free-radical images. Magn. Reson. Med. 47 3 (2002) 571-578
    • (2002) Magn. Reson. Med. , vol.47 , Issue.3 , pp. 571-578
    • He, G.1    Deng, Y.2    Li, H.3    Kuppusamy, P.4    Zweier, J.L.5
  • 3
    • 0036158635 scopus 로고    scopus 로고
    • Experimental investigation of RF magnetic field homogeneity in a bridged loop-gap resonator
    • Ono M., Suenaga A., and Hirata H. Experimental investigation of RF magnetic field homogeneity in a bridged loop-gap resonator. Magn. Reson. Med. 47 2 (2002) 415-419
    • (2002) Magn. Reson. Med. , vol.47 , Issue.2 , pp. 415-419
    • Ono, M.1    Suenaga, A.2    Hirata, H.3
  • 6
    • 4544236089 scopus 로고    scopus 로고
    • Radio frequency continuous-wave and time-domain EPR imaging and Overhauser-enhanced magnetic resonance imaging of small animals: instrumental developments and comparison of relative merits for functional imaging
    • Subramanian S., Matsumoto K., Mitchell J.B., and Krishna M.C. Radio frequency continuous-wave and time-domain EPR imaging and Overhauser-enhanced magnetic resonance imaging of small animals: instrumental developments and comparison of relative merits for functional imaging. NMR Biomed. 17 5 (2004) 263-294
    • (2004) NMR Biomed. , vol.17 , Issue.5 , pp. 263-294
    • Subramanian, S.1    Matsumoto, K.2    Mitchell, J.B.3    Krishna, M.C.4
  • 7
    • 0035983174 scopus 로고    scopus 로고
    • Frequency dependence of EPR signal intensity, 250 MHz to 9.1 GHz
    • Rinard G.A., Quine R.W., Eaton S.S., and Eaton G.R. Frequency dependence of EPR signal intensity, 250 MHz to 9.1 GHz. J. Magn. Reson. 156 1 (2002) 113-121
    • (2002) J. Magn. Reson. , vol.156 , Issue.1 , pp. 113-121
    • Rinard, G.A.1    Quine, R.W.2    Eaton, S.S.3    Eaton, G.R.4
  • 8
    • 0036298942 scopus 로고    scopus 로고
    • Frequency dependence of EPR signal intensity, 248 MHz to 1.4 GHz
    • Rinard G.A., Quine R.W., Eaton S.S., and Eaton G.R. Frequency dependence of EPR signal intensity, 248 MHz to 1.4 GHz. J. Magn. Reson. 154 1 (2002) 80-84
    • (2002) J. Magn. Reson. , vol.154 , Issue.1 , pp. 80-84
    • Rinard, G.A.1    Quine, R.W.2    Eaton, S.S.3    Eaton, G.R.4
  • 9
    • 0001928255 scopus 로고    scopus 로고
    • Frequency dependence of EPR sensitivity
    • Blumler P., Blumich B., Botto R., and Fukushima E. (Eds), Wiley-VCH, Weinheim
    • Eaton G.R., Eaton S.S., and Rinard G.A. Frequency dependence of EPR sensitivity. In: Blumler P., Blumich B., Botto R., and Fukushima E. (Eds). Spatially Resolved Magnetic Resonance (1998), Wiley-VCH, Weinheim
    • (1998) Spatially Resolved Magnetic Resonance
    • Eaton, G.R.1    Eaton, S.S.2    Rinard, G.A.3
  • 10
    • 1242309868 scopus 로고    scopus 로고
    • Aqueous sample in an EPR cavity: sensitivity considerations
    • Nesmelov Y.E., Gopinath A., and Thomas D.D. Aqueous sample in an EPR cavity: sensitivity considerations. J. Magn. Reson. 167 1 (2004) 138-146
    • (2004) J. Magn. Reson. , vol.167 , Issue.1 , pp. 138-146
    • Nesmelov, Y.E.1    Gopinath, A.2    Thomas, D.D.3
  • 11
    • 0002165192 scopus 로고
    • High-frequency continuous wave electron spin resonance
    • Kevan L., and Bowman N.K. (Eds), Wiley, New York
    • Lebedev Y.S. High-frequency continuous wave electron spin resonance. In: Kevan L., and Bowman N.K. (Eds). Modern Pulsed and Continuous-Wave Electron Spin Resonance (1990), Wiley, New York 372
    • (1990) Modern Pulsed and Continuous-Wave Electron Spin Resonance , pp. 372
    • Lebedev, Y.S.1
  • 12
    • 0000501940 scopus 로고
    • Microwave field inhomogeneities and the effect of cavity Q in saturation transfer ESR spectra. Dependence on sample size
    • Fajer P., and Marsh D. Microwave field inhomogeneities and the effect of cavity Q in saturation transfer ESR spectra. Dependence on sample size. J. Magn. Reson. 49 (1982) 212-224
    • (1982) J. Magn. Reson. , vol.49 , pp. 212-224
    • Fajer, P.1    Marsh, D.2
  • 13
    • 0027810984 scopus 로고
    • Field distributions in loop-gap resonators
    • Wojciech P., and Wojciech F. Field distributions in loop-gap resonators. Meas. Sci. Technol. 4 (1993) 1363-1369
    • (1993) Meas. Sci. Technol. , vol.4 , pp. 1363-1369
    • Wojciech, P.1    Wojciech, F.2
  • 14
    • 0010610810 scopus 로고
    • Electron paramagnetic resonance measurements of free radicals in the intact beating heart: a technique for detection and characterization of free radicals in whole biological tissues
    • Zweier J.L., and Kuppusamy P. Electron paramagnetic resonance measurements of free radicals in the intact beating heart: a technique for detection and characterization of free radicals in whole biological tissues. Proc. Natl. Acad. Sci. USA 85 15 (1988) 5703-5707
    • (1988) Proc. Natl. Acad. Sci. USA , vol.85 , Issue.15 , pp. 5703-5707
    • Zweier, J.L.1    Kuppusamy, P.2
  • 16
    • 0032940070 scopus 로고    scopus 로고
    • Optimization of axial RF field distribution in low-frequency EPR loop-gap resonators
    • Diodato R., Alecci M., Brivati J.A., Varoli V., and Sotgiu A. Optimization of axial RF field distribution in low-frequency EPR loop-gap resonators. Phys. Med. Biol. 44 5 (1999) N69-N75
    • (1999) Phys. Med. Biol. , vol.44 , Issue.5
    • Diodato, R.1    Alecci, M.2    Brivati, J.A.3    Varoli, V.4    Sotgiu, A.5
  • 17
    • 0000294172 scopus 로고
    • A radiofrequency ESR spectrometer for in vivo imaging
    • Brivati J.A., and Stevens A.D. A radiofrequency ESR spectrometer for in vivo imaging. J. Magn. Reson. 92 (1991) 480-489
    • (1991) J. Magn. Reson. , vol.92 , pp. 480-489
    • Brivati, J.A.1    Stevens, A.D.2
  • 20
    • 0031866179 scopus 로고    scopus 로고
    • Nitroxide free radical clearance in the live rat monitored by radio-frequency CW-EPR and PEDRI
    • Alecci M., Seimenis I., McCallum S.J., Lurie D.J., and Foster M.A. Nitroxide free radical clearance in the live rat monitored by radio-frequency CW-EPR and PEDRI. Phys. Med. Biol. 43 7 (1998) 1899-1905
    • (1998) Phys. Med. Biol. , vol.43 , Issue.7 , pp. 1899-1905
    • Alecci, M.1    Seimenis, I.2    McCallum, S.J.3    Lurie, D.J.4    Foster, M.A.5
  • 21
    • 34548489942 scopus 로고    scopus 로고
    • J.S. Hyde, W. Froncisz, Loop-gap resonators, in: M.C.R. Symons (Ed.), Electron Spin Resonance. Specialist Periodical Reports, vol. 10, The Royal Society of Chemistry, 1986, pp. 175-184.
  • 23
    • 34548473167 scopus 로고    scopus 로고
    • A. Mehdizadeh, An Investigation on Electromagnetic Fields and Properties of the Loop-Gap Resonator, a Lumped Mode Microwave Resonant Structure, Ph.D. Thesis. Milwaukee, Wisconsine: Marquette University, 1983.
  • 24
    • 34548482081 scopus 로고    scopus 로고
    • Y.D. Shirman, Moscow, Makvis, 1998 (in Russian). Electronic Systems Construction Foundations and Theory Handbook. Makvis, Moscow, 1998, pp 250-252.
  • 25
    • 34548488313 scopus 로고    scopus 로고
    • G.L. Matthaei, L.E. Young, M.T. Jones, Microwave Filters, Impedance-Matching Networks, and Coupling Structures: Mcgraw-Hill Book Company.
  • 26
    • 34547761494 scopus 로고
    • EPR spectroscopy of free radicals in the perfused heart
    • Zweier J.L., and Kuppusamy P. EPR spectroscopy of free radicals in the perfused heart. Curr. Top. Biophys. 18 (1994) 14-25
    • (1994) Curr. Top. Biophys. , vol.18 , pp. 14-25
    • Zweier, J.L.1    Kuppusamy, P.2
  • 27
    • 0025947216 scopus 로고
    • Study of free radicals in the intact beating heart using low frequency electron paramagnetic resonance spectroscopy
    • Zweier J.L., and Kuppusamy P. Study of free radicals in the intact beating heart using low frequency electron paramagnetic resonance spectroscopy. Phys. Med. 7 (1991) 29-37
    • (1991) Phys. Med. , vol.7 , pp. 29-37
    • Zweier, J.L.1    Kuppusamy, P.2
  • 28
    • 34548473899 scopus 로고    scopus 로고
    • A. Samouilov, G.L. Caia, E. Kesselring, S. Petryakov, T. Wasowicz, J.L. Zweier, Development of a hybrid EPR/NMR co-imaging system. Magn. Reson. Med., in press.
  • 29
    • 0033628737 scopus 로고    scopus 로고
    • Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy
    • Hirata H., Walczak T., and Swartz H.M. Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy. J. Magn. Reson. 142 1 (2000) 159-167
    • (2000) J. Magn. Reson. , vol.142 , Issue.1 , pp. 159-167
    • Hirata, H.1    Walczak, T.2    Swartz, H.M.3
  • 30
    • 0035364717 scopus 로고    scopus 로고
    • Characteristics of an electronically tunable surface-coil-type resonator for L-band electron paramagnetic resonance spectroscopy
    • Hirata H., Walczak T., and Swartz H.M. Characteristics of an electronically tunable surface-coil-type resonator for L-band electron paramagnetic resonance spectroscopy. Rev. Sci. Instrum. 72 (2001) 2839-2841
    • (2001) Rev. Sci. Instrum. , vol.72 , pp. 2839-2841
    • Hirata, H.1    Walczak, T.2    Swartz, H.M.3
  • 31
    • 33749003177 scopus 로고    scopus 로고
    • Reactivity of Molecular oxygen with ethoxycarbonyl derivatives of tetrathiatriarylmethyl radicals
    • Xia S., Villamena F.A., Hadad C.M., Kuppusamy P., Li Y., Zhu H., and Zweier J.L. Reactivity of Molecular oxygen with ethoxycarbonyl derivatives of tetrathiatriarylmethyl radicals. J. Org. Chem. 71 (2006) 7268-7279
    • (2006) J. Org. Chem. , vol.71 , pp. 7268-7279
    • Xia, S.1    Villamena, F.A.2    Hadad, C.M.3    Kuppusamy, P.4    Li, Y.5    Zhu, H.6    Zweier, J.L.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.