Volumn 184, Issue 1, 2007, Pages 29-38

Use of multi-coil parallel-gap resonators for co-registration EPR/NMR imaging

Author keywords

Co registration imaging; EPR NMR imaging; Implementation; Resonator

Indexed keywords

BIOMEDICAL ENGINEERING; MAGNETIC FIELDS; NATURAL FREQUENCIES; NUCLEAR MAGNETIC RESONANCE; PARAMAGNETIC RESONANCE; PROBLEM SOLVING; RESONATORS;

EID: 33846005859     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2006.09.014     Document Type: Article
Times cited : (33)

References (30)
  • 1
    • 0031143111 scopus 로고    scopus 로고
    • Development of an L-band electron spin resonance/proton nuclear magnetic resonance imaging instrument
    • Sato T., Oikawa K., Ohya-Nishiguchi H., and Kamada H. Development of an L-band electron spin resonance/proton nuclear magnetic resonance imaging instrument. Rev. Sci. Instrum. 68 (1997) 2076-2081
    • (1997) Rev. Sci. Instrum. , vol.68 , pp. 2076-2081
    • Sato, T.1    Oikawa, K.2    Ohya-Nishiguchi, H.3    Kamada, H.4
  • 2
    • 0036187542 scopus 로고    scopus 로고
    • EPR/NMR co-imaging for anatomic registration of free-radical images
    • He G., Deng Y., Li H., Kuppusamy P., and Zweier J.L. EPR/NMR co-imaging for anatomic registration of free-radical images. Magn. Reson. Med. 47 (2002) 571-578
    • (2002) Magn. Reson. Med. , vol.47 , pp. 571-578
    • He, G.1    Deng, Y.2    Li, H.3    Kuppusamy, P.4    Zweier, J.L.5
  • 6
    • 0036708134 scopus 로고    scopus 로고
    • Proton electron double resonance imaging of the in vivo distribution and clearance of a triaryl methyl radical in mice
    • Li H., Deng Y., He G., Kuppusamy P., Lurie D.J., and Zweier J.L. Proton electron double resonance imaging of the in vivo distribution and clearance of a triaryl methyl radical in mice. Magn. Reson. Med. 48 (2002) 530-534
    • (2002) Magn. Reson. Med. , vol.48 , pp. 530-534
    • Li, H.1    Deng, Y.2    He, G.3    Kuppusamy, P.4    Lurie, D.J.5    Zweier, J.L.6
  • 7
    • 0037035298 scopus 로고    scopus 로고
    • Rapid imaging of free radicals in vivo using hybrid FISP field-cycled PEDRI
    • Youngdee W., Lurie D.J., and Foster M.A. Rapid imaging of free radicals in vivo using hybrid FISP field-cycled PEDRI. Phys. Med. Biol. 47 (2002) 1091-1100
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1091-1100
    • Youngdee, W.1    Lurie, D.J.2    Foster, M.A.3
  • 8
    • 0035063576 scopus 로고    scopus 로고
    • New experimental apparatus for multimodal resonance imaging: initial EPRI and NMRI experimental results
    • Giuseppe S.D., Placidi G., and Sotgiu A. New experimental apparatus for multimodal resonance imaging: initial EPRI and NMRI experimental results. Phys. Med. Biol. 46 (2001) 1003-1016
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1003-1016
    • Giuseppe, S.D.1    Placidi, G.2    Sotgiu, A.3
  • 9
    • 0037150358 scopus 로고    scopus 로고
    • First imaging results obtained with a multimodal apparatus combining low-field (35.7 mT) MRI and pulsed EPRI
    • Placidi G., Alecci M., and Stotgiu A. First imaging results obtained with a multimodal apparatus combining low-field (35.7 mT) MRI and pulsed EPRI. Phys. Med. Biol. 47 (2002) N127-N132
    • (2002) Phys. Med. Biol. , vol.47
    • Placidi, G.1    Alecci, M.2    Stotgiu, A.3
  • 10
    • 0001963628 scopus 로고    scopus 로고
    • A combined PEDRI and CW-EPR instrument for detecting free radicals in vivo
    • McCallum S.J., Nicholson I., and Lurie D.J. A combined PEDRI and CW-EPR instrument for detecting free radicals in vivo. J. Magn. Reson. Ser. B 133 (1996) 65-69
    • (1996) J. Magn. Reson. Ser. B , vol.133 , pp. 65-69
    • McCallum, S.J.1    Nicholson, I.2    Lurie, D.J.3
  • 11
    • 0031867506 scopus 로고    scopus 로고
    • Multimodality magnetic resonance systems for studying free radicals in vivo
    • McCallum S.J., Nicholson I., and Lurie D.J. Multimodality magnetic resonance systems for studying free radicals in vivo. Phys. Med. Biol. 43 (1998) 1857-1861
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1857-1861
    • McCallum, S.J.1    Nicholson, I.2    Lurie, D.J.3
  • 14
    • 0019529861 scopus 로고
    • Split-ring resonator for use in magnetic resonance from 200-2000 MHz
    • Hardy W.N., and Whitehead L.A. Split-ring resonator for use in magnetic resonance from 200-2000 MHz. Rev. Sci. Instrum. 52 (1981) 213-216
    • (1981) Rev. Sci. Instrum. , vol.52 , pp. 213-216
    • Hardy, W.N.1    Whitehead, L.A.2
  • 15
    • 49049134325 scopus 로고
    • The loop-gap resonator: a new microwave lumped circuit ESR sample structure
    • Froncisz W., and Hyde J.S. The loop-gap resonator: a new microwave lumped circuit ESR sample structure. J. Magn. Reson. 47 (1982) 515-521
    • (1982) J. Magn. Reson. , vol.47 , pp. 515-521
    • Froncisz, W.1    Hyde, J.S.2
  • 16
    • 21244435505 scopus 로고    scopus 로고
    • Systematic approach to cutoff frequency selection in continuous-wave electron paramagnetic resonance imaging
    • Hirata H., Itoh T., Hosokawa K., Deng Y., and Susaki H. Systematic approach to cutoff frequency selection in continuous-wave electron paramagnetic resonance imaging. J. Magn. Reson. 175 (2005) 177-184
    • (2005) J. Magn. Reson. , vol.175 , pp. 177-184
    • Hirata, H.1    Itoh, T.2    Hosokawa, K.3    Deng, Y.4    Susaki, H.5
  • 17
    • 0001262910 scopus 로고
    • Theory of saturation and double resonance effects in ESR Spectra. III. rf coherence and line shapes
    • Freed J.H., Leniart D.S., and Hyde J.S. Theory of saturation and double resonance effects in ESR Spectra. III. rf coherence and line shapes. J. Chem. Phys. 47 (1967) 2762-2773
    • (1967) J. Chem. Phys. , vol.47 , pp. 2762-2773
    • Freed, J.H.1    Leniart, D.S.2    Hyde, J.S.3
  • 18
    • 0012853379 scopus 로고
    • Visualization of eddy-current losses in L-band ESR imaging
    • Ogata T., Ishikawa Y., Ono M., and Berliner L.J. Visualization of eddy-current losses in L-band ESR imaging. J. Magn. Reson. 97 (1992) 616-622
    • (1992) J. Magn. Reson. , vol.97 , pp. 616-622
    • Ogata, T.1    Ishikawa, Y.2    Ono, M.3    Berliner, L.J.4
  • 19
    • 0036158635 scopus 로고    scopus 로고
    • Experimental investigation of RF magnetic field homogeneity in a bridged loop-gap resonator
    • Ono M., Suenaga A., and Hirata H. Experimental investigation of RF magnetic field homogeneity in a bridged loop-gap resonator. Magn. Reson. Med. 47 (2002) 415-419
    • (2002) Magn. Reson. Med. , vol.47 , pp. 415-419
    • Ono, M.1    Suenaga, A.2    Hirata, H.3
  • 21
    • 33845999173 scopus 로고    scopus 로고
    • G.A. Rinard, G.R. Eaton, Loop-gap resonators, in: S.S. Eaton, G.R. Eaton, L.J. Berliner (Eds.), Biological Magnetic Resonance vol. 24 Biomedical EPR, Part B: Methodology, Instrumentation, and Dynamics, New York, 2005, pp. 19-52.
  • 23
    • 25844471128 scopus 로고    scopus 로고
    • Electron paramagnetic resonance field-modulation eddy-current analysis of silver-plated graphite resonators
    • Mett R.R., Anderson J.R., Sidabras J.W., and Hyde J.S. Electron paramagnetic resonance field-modulation eddy-current analysis of silver-plated graphite resonators. Rev. Sci. Instrum. 76 (2005) 094702
    • (2005) Rev. Sci. Instrum. , vol.76 , pp. 094702
    • Mett, R.R.1    Anderson, J.R.2    Sidabras, J.W.3    Hyde, J.S.4
  • 24
    • 0033628737 scopus 로고    scopus 로고
    • Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy
    • Hirata H., Walczak T., and Swarts H.M. Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy. J. Magn. Reson. 142 (2000) 159-167
    • (2000) J. Magn. Reson. , vol.142 , pp. 159-167
    • Hirata, H.1    Walczak, T.2    Swarts, H.M.3
  • 25
    • 0035364717 scopus 로고    scopus 로고
    • Characteristics of an electronically tunable surface-coil-type resonator for L-band electron paramagnetic resonance spectroscopy
    • Hirata H., Walczak T., and Swarts H.M. Characteristics of an electronically tunable surface-coil-type resonator for L-band electron paramagnetic resonance spectroscopy. Rev. Sci. Instrum. 72 (2001) 2839-2841
    • (2001) Rev. Sci. Instrum. , vol.72 , pp. 2839-2841
    • Hirata, H.1    Walczak, T.2    Swarts, H.M.3
  • 27
    • 33846009343 scopus 로고    scopus 로고
    • S.S. Eaton, G.R. Eaton, EPR imaging, in: G.R. Eaton, S.S. Eaton, K.M. Salikhov (Eds.), Foundations of Modern EPR, Singapore, 1997, pp. 684-694.
  • 28
    • 0001534432 scopus 로고
    • Spectral-spatial two-dimensional electron-paramagnetic-resonance imaging
    • Meltempo M.M., Eaton S.S., and Eaton G.R. Spectral-spatial two-dimensional electron-paramagnetic-resonance imaging. J. Magn. Reson. 72 (1987) 449-455
    • (1987) J. Magn. Reson. , vol.72 , pp. 449-455
    • Meltempo, M.M.1    Eaton, S.S.2    Eaton, G.R.3
  • 29
    • 0028199639 scopus 로고
    • Three-dimensional spectral-spatial EPR imaging of free radicals in the heart: a technique for imaging tissue metabolism and oxygenation
    • Kuppusamy P., Chzhan M., Vij K., Shteynbuk M., Lefer D.J., Giannella E., and Zweier J.L. Three-dimensional spectral-spatial EPR imaging of free radicals in the heart: a technique for imaging tissue metabolism and oxygenation. Proc. Natil. Acad. Sci. USA 91 (1994) 3388-3392
    • (1994) Proc. Natil. Acad. Sci. USA , vol.91 , pp. 3388-3392
    • Kuppusamy, P.1    Chzhan, M.2    Vij, K.3    Shteynbuk, M.4    Lefer, D.J.5    Giannella, E.6    Zweier, J.L.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.