-
1
-
-
4644222787
-
Biomechanics of locked plates and screws
-
Egol K.A., Kubiak E.N., Fulkerson E., Kummer F.J., and Koval K.J. Biomechanics of locked plates and screws. J Orthop Trauma 18 (2004) 488-493
-
(2004)
J Orthop Trauma
, vol.18
, pp. 488-493
-
-
Egol, K.A.1
Kubiak, E.N.2
Fulkerson, E.3
Kummer, F.J.4
Koval, K.J.5
-
2
-
-
4844225504
-
Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws
-
Seebeck J., Goldhahn J., Stadele H., Messmer P., Morlock M.M., and Schneider E. Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws. J Orthop Res 22 (2004) 1237-1242
-
(2004)
J Orthop Res
, vol.22
, pp. 1237-1242
-
-
Seebeck, J.1
Goldhahn, J.2
Stadele, H.3
Messmer, P.4
Morlock, M.M.5
Schneider, E.6
-
3
-
-
0036854433
-
Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology
-
Perren S.M. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg 84B (2002) 1093-1110
-
(2002)
J Bone Joint Surg
, vol.84 B
, pp. 1093-1110
-
-
Perren, S.M.1
-
4
-
-
10644243673
-
Locking Compression Plate (LCP). An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator (PC-Fix)
-
Frigg R. Locking Compression Plate (LCP). An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator (PC-Fix). Injury 32 Suppl (2001) 63-66
-
(2001)
Injury
, vol.32
, Issue.SUPPL
, pp. 63-66
-
-
Frigg, R.1
-
5
-
-
33646477698
-
Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques
-
Fulkerson E., Egol K.A., Kubiak E.N., Liporace F., Kummer F.J., and Koval K.J. Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. J Trauma Injury Infect Crit Care 60 (2006) 830-835
-
(2006)
J Trauma Injury Infect Crit Care
, vol.60
, pp. 830-835
-
-
Fulkerson, E.1
Egol, K.A.2
Kubiak, E.N.3
Liporace, F.4
Kummer, F.J.5
Koval, K.J.6
-
6
-
-
0142168925
-
Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled?
-
Stoffel K., Dieter U., Stachowiak G., Gachter A., and Kuster M.S. Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled?. Injury 34 2 (2003) B11-B19
-
(2003)
Injury
, vol.34
, Issue.2
-
-
Stoffel, K.1
Dieter, U.2
Stachowiak, G.3
Gachter, A.4
Kuster, M.S.5
-
7
-
-
0035292772
-
Influence of the number of cortices on the stiffness of plate fixation of diaphyseal fractures
-
ElMaraghy A.W., ElMaraghy M.W., Nousiainen M., Richards R.R., and Schemitsch E.H. Influence of the number of cortices on the stiffness of plate fixation of diaphyseal fractures. J Orthop Trauma 15 (2001) 186-191
-
(2001)
J Orthop Trauma
, vol.15
, pp. 186-191
-
-
ElMaraghy, A.W.1
ElMaraghy, M.W.2
Nousiainen, M.3
Richards, R.R.4
Schemitsch, E.H.5
-
8
-
-
0029248968
-
A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate, and point contact fixator
-
Miclau T., Remiger A., Tepic S., Lindsey R., and McIff T. A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate, and point contact fixator. J Orthop Trauma 9 (1995) 17-22
-
(1995)
J Orthop Trauma
, vol.9
, pp. 17-22
-
-
Miclau, T.1
Remiger, A.2
Tepic, S.3
Lindsey, R.4
McIff, T.5
-
9
-
-
0033622796
-
Mechanical validation of whole bone composite tibia models
-
Cristofolini L., and Viceconti M. Mechanical validation of whole bone composite tibia models. J Biomech 33 (2000) 279-288
-
(2000)
J Biomech
, vol.33
, pp. 279-288
-
-
Cristofolini, L.1
Viceconti, M.2
-
10
-
-
0030131155
-
Mechanical validation of whole bone composite femur models
-
Cristofolini L., Viceconti M., Cappello A., and Toni A. Mechanical validation of whole bone composite femur models. J Biomech 29 (1996) 525-535
-
(1996)
J Biomech
, vol.29
, pp. 525-535
-
-
Cristofolini, L.1
Viceconti, M.2
Cappello, A.3
Toni, A.4
-
11
-
-
16544395340
-
Has locked plating completely replaced conventional plating?
-
Gardner M.J., Helfet D.L., and Lorich D.G. Has locked plating completely replaced conventional plating?. Am J Orthop 33 (2004) 439-446
-
(2004)
Am J Orthop
, vol.33
, pp. 439-446
-
-
Gardner, M.J.1
Helfet, D.L.2
Lorich, D.G.3
-
12
-
-
0142199888
-
General principles for the clinical use of the LCP
-
Wagner M. General principles for the clinical use of the LCP. Injury 34 2 (2003) B31-B42
-
(2003)
Injury
, vol.34
, Issue.2
-
-
Wagner, M.1
-
13
-
-
0026377901
-
The role of supplemental lag-screw fixation for open fractures of the tibial shaft treated with external fixation
-
Krettek C., Haas N., and Tscherne H. The role of supplemental lag-screw fixation for open fractures of the tibial shaft treated with external fixation. J Bone Joint Surg 73A (1991) 893-897
-
(1991)
J Bone Joint Surg
, vol.73 A
, pp. 893-897
-
-
Krettek, C.1
Haas, N.2
Tscherne, H.3
-
14
-
-
33748453701
-
Hybrid locked plating of osteoporotic fractures of the humerus
-
Gardner M.J., Griffith M.H., Demetrakopoulos D., Brophy R.H., Grose A., Helfet D.L., et al. Hybrid locked plating of osteoporotic fractures of the humerus. J Bone Joint Surg 88A (2006) 1962-1967
-
(2006)
J Bone Joint Surg
, vol.88 A
, pp. 1962-1967
-
-
Gardner, M.J.1
Griffith, M.H.2
Demetrakopoulos, D.3
Brophy, R.H.4
Grose, A.5
Helfet, D.L.6
|