메뉴 건너뛰기




Volumn 32, Issue 7, 2007, Pages 971-975

Biomechanical Evaluation of Locking Plate Radial Shaft Fixation: Unicortical Locking Fixation Versus Mixed Bicortical and Unicortical Fixation in a Sawbone Model

Author keywords

Bicortical; construct stiffness; locked plating; radius; unicortical

Indexed keywords

ARTICLE; BIOMECHANICS; BONE SCREW; FRACTURE FIXATION; HUMAN; HUMAN TISSUE; OSTEOTOMY; PLATE FIXATION; PRIORITY JOURNAL; SURGICAL INSTRUMENT; SURGICAL TECHNIQUE;

EID: 34548395927     PISSN: 03635023     EISSN: 15316564     Source Type: Journal    
DOI: 10.1016/j.jhsa.2007.05.019     Document Type: Article
Times cited : (47)

References (15)
  • 2
    • 4844225504 scopus 로고    scopus 로고
    • Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws
    • Seebeck J., Goldhahn J., Stadele H., Messmer P., Morlock M.M., and Schneider E. Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws. J Orthop Res 22 (2004) 1237-1242
    • (2004) J Orthop Res , vol.22 , pp. 1237-1242
    • Seebeck, J.1    Goldhahn, J.2    Stadele, H.3    Messmer, P.4    Morlock, M.M.5    Schneider, E.6
  • 3
    • 0036854433 scopus 로고    scopus 로고
    • Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology
    • Perren S.M. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg 84B (2002) 1093-1110
    • (2002) J Bone Joint Surg , vol.84 B , pp. 1093-1110
    • Perren, S.M.1
  • 4
    • 10644243673 scopus 로고    scopus 로고
    • Locking Compression Plate (LCP). An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator (PC-Fix)
    • Frigg R. Locking Compression Plate (LCP). An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator (PC-Fix). Injury 32 Suppl (2001) 63-66
    • (2001) Injury , vol.32 , Issue.SUPPL , pp. 63-66
    • Frigg, R.1
  • 5
    • 33646477698 scopus 로고    scopus 로고
    • Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques
    • Fulkerson E., Egol K.A., Kubiak E.N., Liporace F., Kummer F.J., and Koval K.J. Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. J Trauma Injury Infect Crit Care 60 (2006) 830-835
    • (2006) J Trauma Injury Infect Crit Care , vol.60 , pp. 830-835
    • Fulkerson, E.1    Egol, K.A.2    Kubiak, E.N.3    Liporace, F.4    Kummer, F.J.5    Koval, K.J.6
  • 6
    • 0142168925 scopus 로고    scopus 로고
    • Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled?
    • Stoffel K., Dieter U., Stachowiak G., Gachter A., and Kuster M.S. Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled?. Injury 34 2 (2003) B11-B19
    • (2003) Injury , vol.34 , Issue.2
    • Stoffel, K.1    Dieter, U.2    Stachowiak, G.3    Gachter, A.4    Kuster, M.S.5
  • 8
    • 0029248968 scopus 로고
    • A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate, and point contact fixator
    • Miclau T., Remiger A., Tepic S., Lindsey R., and McIff T. A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate, and point contact fixator. J Orthop Trauma 9 (1995) 17-22
    • (1995) J Orthop Trauma , vol.9 , pp. 17-22
    • Miclau, T.1    Remiger, A.2    Tepic, S.3    Lindsey, R.4    McIff, T.5
  • 9
    • 0033622796 scopus 로고    scopus 로고
    • Mechanical validation of whole bone composite tibia models
    • Cristofolini L., and Viceconti M. Mechanical validation of whole bone composite tibia models. J Biomech 33 (2000) 279-288
    • (2000) J Biomech , vol.33 , pp. 279-288
    • Cristofolini, L.1    Viceconti, M.2
  • 10
    • 0030131155 scopus 로고    scopus 로고
    • Mechanical validation of whole bone composite femur models
    • Cristofolini L., Viceconti M., Cappello A., and Toni A. Mechanical validation of whole bone composite femur models. J Biomech 29 (1996) 525-535
    • (1996) J Biomech , vol.29 , pp. 525-535
    • Cristofolini, L.1    Viceconti, M.2    Cappello, A.3    Toni, A.4
  • 11
    • 16544395340 scopus 로고    scopus 로고
    • Has locked plating completely replaced conventional plating?
    • Gardner M.J., Helfet D.L., and Lorich D.G. Has locked plating completely replaced conventional plating?. Am J Orthop 33 (2004) 439-446
    • (2004) Am J Orthop , vol.33 , pp. 439-446
    • Gardner, M.J.1    Helfet, D.L.2    Lorich, D.G.3
  • 12
    • 0142199888 scopus 로고    scopus 로고
    • General principles for the clinical use of the LCP
    • Wagner M. General principles for the clinical use of the LCP. Injury 34 2 (2003) B31-B42
    • (2003) Injury , vol.34 , Issue.2
    • Wagner, M.1
  • 13
    • 0026377901 scopus 로고
    • The role of supplemental lag-screw fixation for open fractures of the tibial shaft treated with external fixation
    • Krettek C., Haas N., and Tscherne H. The role of supplemental lag-screw fixation for open fractures of the tibial shaft treated with external fixation. J Bone Joint Surg 73A (1991) 893-897
    • (1991) J Bone Joint Surg , vol.73 A , pp. 893-897
    • Krettek, C.1    Haas, N.2    Tscherne, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.