메뉴 건너뛰기




Volumn 17, Issue 10, 2007, Pages 977-982

Insertion characteristics, sealing pressure and fiberoptic positioning of CobraPLA in children

Author keywords

Airway; Airway pressure; Equipment; Pediatric anesthesia; Ventilation

Indexed keywords

ARTICLE; ARTIFICIAL VENTILATION; CLINICAL ARTICLE; CONTROLLED STUDY; DEVICE; FIBER OPTICS; HUMAN; INSPIRATORY CAPACITY; MEDICAL INSTRUMENTATION; MUSCLE RELAXATION; PRESCHOOL CHILD; PRIORITY JOURNAL; SAFETY; SCHOOL CHILD;

EID: 34548307052     PISSN: 11555645     EISSN: 14609592     Source Type: Journal    
DOI: 10.1111/j.1460-9592.2007.02241.x     Document Type: Article
Times cited : (12)

References (19)
  • 1
    • 15944383810 scopus 로고    scopus 로고
    • Use of a new supraglottic airway device - The CobraPLA - In a 'difficult to intubate/difficult to ventilate' scenario
    • Szmuk P, Ezri T, Akça O et al. Use of a new supraglottic airway device - the CobraPLA - in a 'difficult to intubate/difficult to ventilate' scenario. Acta Anaesthesiol Scand 2005 49 : 421 423.
    • (2005) Acta Anaesthesiol Scand , vol.49 , pp. 421-423
    • Szmuk, P.1    Ezri, T.2    Akça, O.3
  • 2
    • 31444450732 scopus 로고    scopus 로고
    • A comparison between the PLA Cobra and the laryngeal mask airway unique during spontaneous ventilation: A randomized prospective study
    • Gaitini L, Yanovski B, Somri M et al. A comparison between the PLA Cobra and the laryngeal mask airway unique during spontaneous ventilation: a randomized prospective study. Anesth Analg 2006 102 : 631 636.
    • (2006) Anesth Analg , vol.102 , pp. 631-636
    • Gaitini, L.1    Yanovski, B.2    Somri, M.3
  • 3
    • 3042660598 scopus 로고    scopus 로고
    • The new perilaryngeal airway (CobraPLA) is as efficient as the laryngeal mask airway (LMA) but provides better airway sealing pressures
    • Akça O, Wadhwa A, Sengupta P et al. The new perilaryngeal airway (CobraPLA) is as efficient as the laryngeal mask airway (LMA) but provides better airway sealing pressures. Anesth Analg 2004 99 : 272 278.
    • (2004) Anesth Analg , vol.99 , pp. 272-278
    • Akça, O.1    Wadhwa, A.2    Sengupta, P.3
  • 4
    • 21444440094 scopus 로고    scopus 로고
    • Use of CobraPLA for airway management in a neonate with Desbuquois syndrome. Case report and anaesthetic implications
    • Szmuk P, Matuszczeak M, Carlson R et al. Use of CobraPLA for airway management in a neonate with Desbuquois syndrome. Case report and anaesthetic implications. Pediatr Anesth 2005 15 : 602 605.
    • (2005) Pediatr Anesth , vol.15 , pp. 602-605
    • Szmuk, P.1    Matuszczeak, M.2    Carlson, R.3
  • 5
    • 17044432302 scopus 로고    scopus 로고
    • CobraPLA as a conduit for flexible bronchoscopy in a child under general anaesthesia
    • Szmuk P, Ghelber O, Akça O et al. CobraPLA as a conduit for flexible bronchoscopy in a child under general anaesthesia. Br J Anaesth 2005 94 : 548 549.
    • (2005) Br J Anaesth , vol.94 , pp. 548-549
    • Szmuk, P.1    Ghelber, O.2    Akça, O.3
  • 6
    • 33645213222 scopus 로고    scopus 로고
    • Use of CobraPLA as a conduit for fiberoptic intubation in a child with neck instability
    • Szmuk P, Ezri T, Narwani A et al. Use of CobraPLA as a conduit for fiberoptic intubation in a child with neck instability. Pediatr Anesth 2006 16 : 216 225.
    • (2006) Pediatr Anesth , vol.16 , pp. 216-225
    • Szmuk, P.1    Ezri, T.2    Narwani, A.3
  • 7
    • 0027528467 scopus 로고
    • A proposed fiberoptic scoring system to standardize the assessment of laryngeal mask airway position
    • Brimacombe J, Berry A. A proposed fiberoptic scoring system to standardize the assessment of laryngeal mask airway position. Anesth Analg 1993 76 : 457.
    • (1993) Anesth Analg , vol.76 , pp. 457
    • Brimacombe, J.1    Berry, A.2
  • 8
    • 0027521524 scopus 로고
    • The laryngeal mask airway: Anesthetic gas leakge and fiberoptic control of positioning
    • Füllekrug B, Pothmann W, Werner C et al. The laryngeal mask airway: anesthetic gas leakge and fiberoptic control of positioning. J Clin Anesth 1993 5 : 357 363.
    • (1993) J Clin Anesth , vol.5 , pp. 357-363
    • Füllekrug, B.1    Pothmann, W.2    Werner, C.3
  • 9
    • 0032908319 scopus 로고    scopus 로고
    • Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients
    • Keller C, Brimacombe JR, Keller K et al. Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth 1999 82 : 286 287.
    • (1999) Br J Anaesth , vol.82 , pp. 286-287
    • Keller, C.1    Brimacombe, J.R.2    Keller, K.3
  • 10
    • 33344460878 scopus 로고    scopus 로고
    • TM) and laryngeal tube with the new perilaryngeal airway (CobraPLA) in short surgical procedures
    • TM) and laryngeal tube with the new perilaryngeal airway (CobraPLA) in short surgical procedures. Eur J Anaesthesiol 2006 23 : 234 238.
    • (2006) Eur J Anaesthesiol , vol.23 , pp. 234-238
    • Turan, A.1    Kaya, G.2    Koyuncu, O.3
  • 11
    • 0029913442 scopus 로고    scopus 로고
    • Airway sealing pressures of the laryngeal mask airway in pediatric patients
    • Epstein RH, Ferouz F, Jenkins MA. Airway sealing pressures of the laryngeal mask airway in pediatric patients. J Clin Anesth 1996 8 : 93 98.
    • (1996) J Clin Anesth , vol.8 , pp. 93-98
    • Epstein, R.H.1    Ferouz, F.2    Jenkins, M.A.3
  • 12
    • 0026676887 scopus 로고
    • Radiologic localization of the laryngeal mask airway in children
    • Goudsouzian NG, Denman W, Cleveland R et al. Radiologic localization of the laryngeal mask airway in children. Anesthesiology 1992 77 : 1085 1089.
    • (1992) Anesthesiology , vol.77 , pp. 1085-1089
    • Goudsouzian, N.G.1    Denman, W.2    Cleveland, R.3
  • 13
    • 0030053061 scopus 로고    scopus 로고
    • Positive pressure ventilation with the laryngeal mask airway in children
    • Gursoy F, Algren JT, Skjonsby BS. Positive pressure ventilation with the laryngeal mask airway in children. Anesth Analg 1996 82 : 33 38.
    • (1996) Anesth Analg , vol.82 , pp. 33-38
    • Gursoy, F.1    Algren, J.T.2    Skjonsby, B.S.3
  • 14
    • 0034767534 scopus 로고    scopus 로고
    • Pressure versus volume-controlled ventilation with a laryngeal mask airway in paediatric patients
    • Keidan I, Berkenstadt H, Segal E et al. Pressure versus volume-controlled ventilation with a laryngeal mask airway in paediatric patients. Paediatr Anaesth 2001 11 : 691 694.
    • (2001) Paediatr Anaesth , vol.11 , pp. 691-694
    • Keidan, I.1    Berkenstadt, H.2    Segal, E.3
  • 15
    • 33845689246 scopus 로고    scopus 로고
    • Pressure-controlled ventilation is superior to volume-controlled ventilation with a laryngeal mask airway in children
    • Bordes M, Semjen F, Degryse C et al. Pressure-controlled ventilation is superior to volume-controlled ventilation with a laryngeal mask airway in children. Acta Anaesthesiol Scand 2007 51 : 82 85.
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 82-85
    • Bordes, M.1    Semjen, F.2    Degryse, C.3
  • 16
    • 33645224916 scopus 로고    scopus 로고
    • Comparison of cuffed, uncuffed tracheal tubes and laryngeal mask airways in low flow pressure controlled ventilation in children
    • Engelhardt T, Johnston G, Kumar MM. Comparison of cuffed, uncuffed tracheal tubes and laryngeal mask airways in low flow pressure controlled ventilation in children. Pediatr Anesth 2006 16 : 140 143.
    • (2006) Pediatr Anesth , vol.16 , pp. 140-143
    • Engelhardt, T.1    Johnston, G.2    Kumar, M.M.3
  • 18
    • 0035000358 scopus 로고    scopus 로고
    • The laryngeal mask airway in children and infants
    • Park C, Bahk J-H, Ahn W-S et al. The laryngeal mask airway in children and infants. Can J Anaesth 2001 48 : 413 417.
    • (2001) Can J Anaesth , vol.48 , pp. 413-417
    • Park, C.1    Bahk, J.-H.2    Ahn, W.-S.3
  • 19
    • 34548330858 scopus 로고    scopus 로고
    • Author reply In: Cook TM, Lowe J. More on the CobraPLA
    • Alfery D, Quinn B. Author reply In: Cook TM, Lowe J. More on the CobraPLA. Anaesthesia 2005 60 : 1145 1147.
    • (2005) Anaesthesia , vol.60 , pp. 1145-1147
    • Alfery, D.1    Quinn, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.