메뉴 건너뛰기




Volumn 129, Issue 4, 2007, Pages 481-486

Effects of thresholding techniques on μCT-based finite element models of trabecular bone

Author keywords

Finite element analysis; Mechanical properties; Micro computed tomography; Thresholding; Trabecular bone

Indexed keywords

COMPUTERIZED TOMOGRAPHY; FINITE ELEMENT METHOD; MATHEMATICAL MODELS; MECHANICAL PROPERTIES;

EID: 34548152704     PISSN: 01480731     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.2746368     Document Type: Article
Times cited : (38)

References (24)
  • 1
    • 0030634802 scopus 로고    scopus 로고
    • Assessment of Trabecular Structure Using High Resolution Magnetic Resonance Imaging
    • Majumdar, S., and Genant, H. K., 1997, "Assessment of Trabecular Structure Using High Resolution Magnetic Resonance Imaging," Stud. Health Technol. Inform., 40, pp. 81-96.
    • (1997) Stud. Health Technol. Inform , vol.40 , pp. 81-96
    • Majumdar, S.1    Genant, H.K.2
  • 2
    • 0031032812 scopus 로고    scopus 로고
    • Correlation of Trabecular Bone Structure With Age, Bone Mineral Density, and Osteoporotic Status: In Vivo Studies in the Distal Radius Using High Resolution Magnetic Resonance Imaging
    • Majumdar, S., Genant, H. K., Grampp, S., Newitt, D. C., Truong, V. H., Lin, J. C., and Mathur, A., 1997, "Correlation of Trabecular Bone Structure With Age, Bone Mineral Density, and Osteoporotic Status: In Vivo Studies in the Distal Radius Using High Resolution Magnetic Resonance Imaging," J. Bone Miner. Res., 12, pp. 111-118.
    • (1997) J. Bone Miner. Res , vol.12 , pp. 111-118
    • Majumdar, S.1    Genant, H.K.2    Grampp, S.3    Newitt, D.C.4    Truong, V.H.5    Lin, J.C.6    Mathur, A.7
  • 3
    • 0025514438 scopus 로고
    • Evaluation of a Microcomputed Tomography System to Study Trabecular Bone Structure
    • Kuhn, J. L., Goldstein, S. A., Feldkamp, L. A., Goulet, R. W., and Jesion, G., 1990, "Evaluation of a Microcomputed Tomography System to Study Trabecular Bone Structure," J. Orthop. Res., 8, pp. 833-842.
    • (1990) J. Orthop. Res , vol.8 , pp. 833-842
    • Kuhn, J.L.1    Goldstein, S.A.2    Feldkamp, L.A.3    Goulet, R.W.4    Jesion, G.5
  • 4
    • 0030071062 scopus 로고    scopus 로고
    • A Microtomographic System for the Nondestructive Evaluation of Bone Architecture
    • Ruegsegger, P., Roller, B., and Muller, R., 1996, "A Microtomographic System for the Nondestructive Evaluation of Bone Architecture," Calcif. Tissue Int., 58, pp. 24-29.
    • (1996) Calcif. Tissue Int , vol.58 , pp. 24-29
    • Ruegsegger, P.1    Roller, B.2    Muller, R.3
  • 5
    • 0030062696 scopus 로고    scopus 로고
    • Trabecular Bone Morphology from Micro-Magnetic Resonance Imaging
    • Hipp, J. A., Jansujwicz, A., Simmons, C. A., and Snyder, B. D., 1996, "Trabecular Bone Morphology from Micro-Magnetic Resonance Imaging," J. Bone Miner. Res., 11, pp. 286-297.
    • (1996) J. Bone Miner. Res , vol.11 , pp. 286-297
    • Hipp, J.A.1    Jansujwicz, A.2    Simmons, C.A.3    Snyder, B.D.4
  • 7
    • 0345040851 scopus 로고    scopus 로고
    • Tissue Stresses and Strain in Trabeculae of a Canine Proximal Femur Can Be Quantified from Computer Reconstructions
    • Van Rietbergen, B., Muller, R., Ulrich, D., Ruegsegger, P., and Huiskes, R., 1999, "Tissue Stresses and Strain in Trabeculae of a Canine Proximal Femur Can Be Quantified from Computer Reconstructions," J. Biomech., 32, pp. 165-173.
    • (1999) J. Biomech , vol.32 , pp. 165-173
    • Van Rietbergen, B.1    Muller, R.2    Ulrich, D.3    Ruegsegger, P.4    Huiskes, R.5
  • 8
    • 0034115331 scopus 로고    scopus 로고
    • Speed of Sound Reflects Young's Modulus as Assessed by Microstructural Finite Element Analysis
    • van den Bergh, J. P., van Lenthe, G. H., Hermus, A. R., Corstens, F. H., Smals, A. G., and Huiskes, R., 2000, "Speed of Sound Reflects Young's Modulus as Assessed by Microstructural Finite Element Analysis," Bone (N.Y.), 26, pp. 519-524.
    • (2000) Bone (N.Y.) , vol.26 , pp. 519-524
    • van den Bergh, J.P.1    van Lenthe, G.H.2    Hermus, A.R.3    Corstens, F.H.4    Smals, A.G.5    Huiskes, R.6
  • 9
    • 0033811123 scopus 로고    scopus 로고
    • High-Resolution Finite Element Models With Tissue Strength Asymmetry Accurately Predict Failure of Trabecular Bone
    • Niebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., and Keaveny, T. M., 2000, "High-Resolution Finite Element Models With Tissue Strength Asymmetry Accurately Predict Failure of Trabecular Bone," J. Biomech., 33, pp. 1575-1583.
    • (2000) J. Biomech , vol.33 , pp. 1575-1583
    • Niebur, G.L.1    Feldstein, M.J.2    Yuen, J.C.3    Chen, T.J.4    Keaveny, T.M.5
  • 10
    • 0035061851 scopus 로고    scopus 로고
    • Sensitivity of Damage Predictions to Tissue Level Yield Properties and Apparent Loading Conditions
    • Niebur, G. L., Yuen, J. C., Burghardt, A. J., and Keaveny, T. M., 2001, "Sensitivity of Damage Predictions to Tissue Level Yield Properties and Apparent Loading Conditions," J. Biomech., 34, pp. 699-706.
    • (2001) J. Biomech , vol.34 , pp. 699-706
    • Niebur, G.L.1    Yuen, J.C.2    Burghardt, A.J.3    Keaveny, T.M.4
  • 11
    • 0033294444 scopus 로고    scopus 로고
    • Convergence Behavior of High-Resolution Finite Element Models of Trabecular Bone
    • Niebur, G. L., Yuen, J. C., Hsia, A. C., and Keaveny, T. M., 1999, "Convergence Behavior of High-Resolution Finite Element Models of Trabecular Bone," J. Biomech. Eng., 121, pp. 629-635.
    • (1999) J. Biomech. Eng , vol.121 , pp. 629-635
    • Niebur, G.L.1    Yuen, J.C.2    Hsia, A.C.3    Keaveny, T.M.4
  • 12
    • 0035870103 scopus 로고    scopus 로고
    • Three-Dimensional Microimaging (Mrmicroi and Microct), Finite Element Modeling, and Rapid Prototyping Provide Unique Insights into Bone Architecture in Osteoporosis
    • Borah, B., Gross, G. J., Dufresne, T. E., Smith, T. S., Cockman, M. D., Chmielewski, P. A., Lundy, M. W., Hartke, J. R., and Sod, E. W., 2001, "Three-Dimensional Microimaging (Mrmicroi and Microct), Finite Element Modeling, and Rapid Prototyping Provide Unique Insights into Bone Architecture in Osteoporosis," Anat. Rec., 265, pp. 101-110.
    • (2001) Anat. Rec , vol.265 , pp. 101-110
    • Borah, B.1    Gross, G.J.2    Dufresne, T.E.3    Smith, T.S.4    Cockman, M.D.5    Chmielewski, P.A.6    Lundy, M.W.7    Hartke, J.R.8    Sod, E.W.9
  • 13
    • 0033988618 scopus 로고    scopus 로고
    • Improving the Local Solution Accuracy of Large-Scale Digital Image-Based Finite Element Analyses
    • Charras, G. T., and Guldberg, R. E., 2000, "Improving the Local Solution Accuracy of Large-Scale Digital Image-Based Finite Element Analyses," J. Biomech., 33, pp. 255-259.
    • (2000) J. Biomech , vol.33 , pp. 255-259
    • Charras, G.T.1    Guldberg, R.E.2
  • 14
    • 0030630672 scopus 로고    scopus 로고
    • The Quality of Trabecular Bone Evaluated with Micro-Computed Tomography, Fea and Mechanical Testing
    • Ulrich, D., Hildebrand, T., Van Rietbergen, B., Muller, R., and Ruegsegger, P., 1997, "The Quality of Trabecular Bone Evaluated with Micro-Computed Tomography, Fea and Mechanical Testing," Stud. Health Technol. Inform., 40, pp. 97-112.
    • (1997) Stud. Health Technol. Inform , vol.40 , pp. 97-112
    • Ulrich, D.1    Hildebrand, T.2    Van Rietbergen, B.3    Muller, R.4    Ruegsegger, P.5
  • 15
    • 0032412757 scopus 로고    scopus 로고
    • Finite Element Analysis of Trabecular Bone Structure: A Comparison of Image-Based Meshing Techniques
    • Ulrich, D., van Rietbergen, B., Weinans, H., and Ruegsegger, P., 1998, "Finite Element Analysis of Trabecular Bone Structure: A Comparison of Image-Based Meshing Techniques," J. Biomech., 31, pp. 1187-1192.
    • (1998) J. Biomech , vol.31 , pp. 1187-1192
    • Ulrich, D.1    van Rietbergen, B.2    Weinans, H.3    Ruegsegger, P.4
  • 16
    • 0032054795 scopus 로고    scopus 로고
    • The Accuracy of Digital Image-Based Finite Element Models
    • Guldberg, R. E., Hollister, S. J., and Charras, G. T., 1998, "The Accuracy of Digital Image-Based Finite Element Models," J. Biomech. Eng., 120, pp. 289-295.
    • (1998) J. Biomech. Eng , vol.120 , pp. 289-295
    • Guldberg, R.E.1    Hollister, S.J.2    Charras, G.T.3
  • 17
    • 0032171053 scopus 로고    scopus 로고
    • FiniteElement Modeling of Trabecular Bone: Comparison with Mechanical Testing and Determination of Tissue Modulus
    • Ladd, A. J., Kinney, J. H., Haupt, D. L., and Goldstein, S. A., 1998, "FiniteElement Modeling of Trabecular Bone: Comparison with Mechanical Testing and Determination of Tissue Modulus," J. Orthop. Res., 16, pp. 622-628.
    • (1998) J. Orthop. Res , vol.16 , pp. 622-628
    • Ladd, A.J.1    Kinney, J.H.2    Haupt, D.L.3    Goldstein, S.A.4
  • 18
    • 0035099733 scopus 로고    scopus 로고
    • Introduction and Evaluation of a Gray-Value Voxel Conversion Technique
    • Homminga, J., Huiskes, R., Van Rietbergen, B., Ruegsegger, P., and Weinans, H., 2001, "Introduction and Evaluation of a Gray-Value Voxel Conversion Technique," J. Biomech., 34, pp. 513-517.
    • (2001) J. Biomech , vol.34 , pp. 513-517
    • Homminga, J.1    Huiskes, R.2    Van Rietbergen, B.3    Ruegsegger, P.4    Weinans, H.5
  • 19
    • 0036309436 scopus 로고    scopus 로고
    • The Influence of Microcomputed Tomography Threshold Variations on the Assessment of Structural and Mechanical Trabecular Bone Properties
    • Hara, T., Tanck, E., Homminga, J., and Huiskes, R., 2002, "The Influence of Microcomputed Tomography Threshold Variations on the Assessment of Structural and Mechanical Trabecular Bone Properties," Bone (N.Y.), 31, pp. 107-109.
    • (2002) Bone (N.Y.) , vol.31 , pp. 107-109
    • Hara, T.1    Tanck, E.2    Homminga, J.3    Huiskes, R.4
  • 20
    • 0028504004 scopus 로고
    • Trabecular Bone Exhibits Fully Linear Elastic Behavior and Yields at Low Strains
    • Keaveny, T. M., Guo, X. E., Wachtel, E. F., McMahon, T. A., and Hayes, W. C., 1994, "Trabecular Bone Exhibits Fully Linear Elastic Behavior and Yields at Low Strains," J. Biomech., 27, pp. 1127-1136.
    • (1994) J. Biomech , vol.27 , pp. 1127-1136
    • Keaveny, T.M.1    Guo, X.E.2    Wachtel, E.F.3    McMahon, T.A.4    Hayes, W.C.5
  • 21
    • 0028414083 scopus 로고
    • A Homogenization Sampling Procedure for Calculating Trabecular Bone Effective Stiffness and Tissue Level Stress
    • Hollister, S. J., Brennan, J. M., and Kikuchi, N., 1994, "A Homogenization Sampling Procedure for Calculating Trabecular Bone Effective Stiffness and Tissue Level Stress," J. Biomech., 27, pp. 433-444.
    • (1994) J. Biomech , vol.27 , pp. 433-444
    • Hollister, S.J.1    Brennan, J.M.2    Kikuchi, N.3
  • 22
    • 0000669189 scopus 로고    scopus 로고
    • Is Trabecular Bone Tissue Different from Cortical Bone Tissue?
    • Guo, X. E., and Goldstein, S. A., 1997, "Is Trabecular Bone Tissue Different from Cortical Bone Tissue?," Forma, 12, pp. 185-196.
    • (1997) Forma , vol.12 , pp. 185-196
    • Guo, X.E.1    Goldstein, S.A.2
  • 23
    • 0028936206 scopus 로고
    • A New Method to Determine Trabecular Bone Elastic Properties and Loading Using Micromechanical Finite-Element Models
    • van Rietbergen, B., Weinans, H., Huiskes, R., and Odgaard, A., 1995, "A New Method to Determine Trabecular Bone Elastic Properties and Loading Using Micromechanical Finite-Element Models," J. Biomech., 28, pp. 69-81.
    • (1995) J. Biomech , vol.28 , pp. 69-81
    • van Rietbergen, B.1    Weinans, H.2    Huiskes, R.3    Odgaard, A.4
  • 24
    • 0033047422 scopus 로고    scopus 로고
    • Direct Three-Dimensional Morphometric Analysis of Human Cancellous Bone: Microstructural Data from Spine, Femur, Iliac Crest, and Calcaneus
    • Hildebrand, T., Laib, A., Muller, R., Dequeker, J., and Ruegsegger, P., 1999, "Direct Three-Dimensional Morphometric Analysis of Human Cancellous Bone: Microstructural Data from Spine, Femur, Iliac Crest, and Calcaneus," J. Bone Miner. Res., 14, pp. 1167-1174.
    • (1999) J. Bone Miner. Res , vol.14 , pp. 1167-1174
    • Hildebrand, T.1    Laib, A.2    Muller, R.3    Dequeker, J.4    Ruegsegger, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.