1
-
-
0023890926
-
Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis
-
1:STN:280:BieC2MzotFc%3D
-
Agins HJ, Alcock NW, Bansal M, et al (1988) Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis. J Bone Joint Surg Br 70:347-356 1:STN:280:BieC2MzotFc%3D
-
(1988)
J. Bone Joint Surg. Br.
, vol.70
, pp. 347-356
-
-
Agins, H.J.1
Alcock, N.W.2
Bansal, M.3
-
2
-
-
0026605414
-
Mechanism and clinical significance of wear debris-induced osteolysis
-
1537177
-
Amstutz HC, Campbell P, Kossovsky N, et al (1992) Mechanism and clinical significance of wear debris-induced osteolysis. Clin Orthop 276:7-18 1537177
-
(1992)
Clin. Orthop.
, vol.276
, pp. 7-18
-
-
Amstutz, H.C.1
Campbell, P.2
Kossovsky, N.3
-
3
-
-
0033022657
-
Postoperative deep wound infection in instrumented spinal surgery
-
1:STN:280:DyaK1Mzls1yjtQ%3D%3D
-
Aydinli U, Karaeminogullari O, Tiskaya K (1999) Postoperative deep wound infection in instrumented spinal surgery. Acta Orthop Belg 65:182-187 1:STN:280:DyaK1Mzls1yjtQ%3D%3D
-
(1999)
Acta Orthop. Belg.
, vol.65
, pp. 182-187
-
-
Aydinli, U.1
Karaeminogullari, O.2
Tiskaya, K.3
-
4
-
-
0028243329
-
Neurologic injury after insertion of laminar hooks during Cotrel-Dubousset instrumentation
-
1:STN:280:ByuA2crks1Q%3D
-
Been HD, Kalkman CJ, Traast HS, et al (1994) Neurologic injury after insertion of laminar hooks during Cotrel-Dubousset instrumentation. Spine 19:1402-1405 1:STN:280:ByuA2crks1Q%3D
-
(1994)
Spine
, vol.19
, pp. 1402-1405
-
-
Been, H.D.1
Kalkman, C.J.2
Traast, H.S.3
-
5
-
-
0035074458
-
Titanium particles stimulate bone resorption by inducing differentiation of murine osteoclasts
-
11315778
-
Bi Y, Van de Motter RR, Ragap AA, et al (2001) Titanium particles stimulate bone resorption by inducing differentiation of murine osteoclasts. J Bone Joint Surg Am 83:501-508 11315778
-
(2001)
J. Bone Joint Surg. Am.
, vol.83
, pp. 501-508
-
-
Bi, Y.1
Van de Motter, R.R.2
Ragap, A.A.3
-
6
-
-
0028024211
-
Wear induced by motion between bone and titanium or cobalt-chrome alloys
-
1:STN:280:ByuA28rgsFw%3D
-
Bischoff UW, Freeman MAR, Smith D, et al (1994) Wear induced by motion between bone and titanium or cobalt-chrome alloys. J Bone Joint Surg Br 76:713-716 1:STN:280:ByuA28rgsFw%3D
-
(1994)
J. Bone Joint Surg. Br.
, vol.76
, pp. 713-716
-
-
Bischoff, U.W.1
Freeman, M.A.R.2
Smith, D.3
-
7
-
-
0024059621
-
Editorial. Does corrosion matter?
-
1:STN:280:BieB1Mfptl0%3D
-
Black J (1988) Editorial. Does corrosion matter? J Bone Joint Surg Br 70:517-520 1:STN:280:BieB1Mfptl0%3D
-
(1988)
J. Bone Joint Surg. Br.
, vol.70
, pp. 517-520
-
-
Black, J.1
-
8
-
-
0025137538
-
Metallosis associated with a stable titanium-alloy femoral component in total hip replacement: A case report
-
1:STN:280:By%2BC3M%2FislA%3D
-
Black J, Sherk H, Bonini J, et al (1990) Metallosis associated with a stable titanium-alloy femoral component in total hip replacement: A case report. J Bone Joint Surg Am 72:126-130 1:STN:280:By%2BC3M%2FislA%3D
-
(1990)
J. Bone Joint Surg. Am.
, vol.72
, pp. 126-130
-
-
Black, J.1
Sherk, H.2
Bonini, J.3
-
9
-
-
0028124561
-
Metallosis
-
1:STN:280:ByuA28rgsFA%3D (editorial)
-
Bullough PG (1994) Metallosis (editorial). J Bone Joint Surg Br 76:687-688 1:STN:280:ByuA28rgsFA%3D
-
(1994)
J. Bone Joint Surg. Br.
, vol.76
, pp. 687-688
-
-
Bullough, P.G.1
-
10
-
-
0028001457
-
Widespread dissemination of metal debris from implants
-
1:STN:280:ByuA28rgsFM%3D
-
Case CP, Langkamer VG, James C, et al (1994) Widespread dissemination of metal debris from implants. J Bone Joint Surg Br 76:701-712 1:STN:280:ByuA28rgsFM%3D
-
(1994)
J. Bone Joint Surg. Br.
, vol.76
, pp. 701-712
-
-
Case, C.P.1
Langkamer, V.G.2
James, C.3
-
11
-
-
0021905513
-
Clinical and metallurgical analysis of retrieved internal fixation devices
-
3978921
-
Cook SD, Renz EA, Barrack RL, et al (1985) Clinical and metallurgical analysis of retrieved internal fixation devices. Clin Orthop 194:236-247 3978921
-
(1985)
Clin. Orthop.
, vol.194
, pp. 236-247
-
-
Cook, S.D.1
Renz, E.A.2
Barrack, R.L.3
-
12
-
-
0027247911
-
Current concepts in orthopaedic biomaterials and implant fixation
-
Friedman RJ, Black J, Galante JO, et al (1993) Current concepts in orthopaedic biomaterials and implant fixation. J Bone Joint Surg Am 75:1086-1109
-
(1993)
J. Bone Joint Surg. Am.
, vol.75
, pp. 1086-1109
-
-
Friedman, R.J.1
Black, J.2
Galante, J.O.3
-
13
-
-
0027171320
-
The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles
-
1:STN:280:ByyA3c%2FoslE%3D
-
Haynes DR, Rogers SD, Hay S, et al (1993) The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles. J Bone Joint Surg Am 75:825-834 1:STN:280:ByyA3c%2FoslE%3D
-
(1993)
J. Bone Joint Surg. Am.
, vol.75
, pp. 825-834
-
-
Haynes, D.R.1
Rogers, S.D.2
Hay, S.3
-
14
-
-
0032997938
-
Metallosis due to impingement between the socket and the femoral neck in a metal-on-metal bearing total hip prosthesis: A case report
-
1:STN:280:DyaK1M3htleksw%3D%3D
-
Iida H, Kaneda E, Takada H, et al (1999) Metallosis due to impingement between the socket and the femoral neck in a metal-on-metal bearing total hip prosthesis: A case report. J Bone Joint Surg Am 81:400-403 1:STN:280:DyaK1M3htleksw%3D%3D
-
(1999)
J. Bone Joint Surg. Am.
, vol.81
, pp. 400-403
-
-
Iida, H.1
Kaneda, E.2
Takada, H.3
-
15
-
-
0031915540
-
Current concepts review. Corrosion of metal orthopaedic implants
-
1:STN:280:DyaK1c7ks1Wguw%3D%3D
-
Jacobs JJ, Gilbert JL, Urban RM (1998) Current concepts review. Corrosion of metal orthopaedic implants. J Bone Joint Surg Am 80:268-282 1:STN:280:DyaK1c7ks1Wguw%3D%3D
-
(1998)
J. Bone Joint Surg. Am.
, vol.80
, pp. 268-282
-
-
Jacobs, J.J.1
Gilbert, J.L.2
Urban, R.M.3
-
16
-
-
0026443512
-
Acrylic fragmentation in total hip replacements and its biological consequences
-
1446427
-
Jasty M, Jiranek W, Harris WH (1992) Acrylic fragmentation in total hip replacements and its biological consequences. Clin Orthop 285:116-128 1446427
-
(1992)
Clin. Orthop.
, vol.285
, pp. 116-128
-
-
Jasty, M.1
Jiranek, W.2
Harris, W.H.3
-
17
-
-
0027400764
-
A histological and biochemical comparison of the interface tissues in cementless and cemented hip prosthesis
-
8448933
-
Kim KJ, Rubash HE, Wilson SC, et al (1993) A histological and biochemical comparison of the interface tissues in cementless and cemented hip prosthesis. Clin Orthop 287:142-152 8448933
-
(1993)
Clin. Orthop.
, vol.287
, pp. 142-152
-
-
Kim, K.J.1
Rubash, H.E.2
Wilson, S.C.3
-
18
-
-
0020617104
-
Corrosion of titanium/cobalt-chromium alloy couples
-
1:STN:280:BiuD3s3mtVY%3D
-
Kummer FJ, Rose RM (1983) Corrosion of titanium/cobalt-chromium alloy couples. J Bone Joint Surg Am 65:1125-1126 1:STN:280:BiuD3s3mtVY%3D
-
(1983)
J. Bone Joint Surg. Am.
, vol.65
, pp. 1125-1126
-
-
Kummer, F.J.1
Rose, R.M.2
-
19
-
-
0027236411
-
Fibroblast response to metallic debris in vitro. Enzym induction, cell proliferation, and toxicity
-
1:STN:280:ByyA3c%2FoslI%3D
-
Maloney WJ, Smith RL, Schurman DJ (1993) Fibroblast response to metallic debris in vitro. Enzym induction, cell proliferation, and toxicity. J Bone Joint Surg Am 75:835-844 1:STN:280:ByyA3c%2FoslI%3D
-
(1993)
J. Bone Joint Surg. Am.
, vol.75
, pp. 835-844
-
-
Maloney, W.J.1
Smith, R.L.2
Schurman, D.J.3
-
20
-
-
0026454751
-
Severe metallosis due to abnormal abrasion of the femoral head in a dual-bearing hip prosthesis: A case report
-
Matsuda Y, Yamamuro T, Kasai R, et al (1992) Severe metallosis due to abnormal abrasion of the femoral head in a dual-bearing hip prosthesis: a case report. J Arthroplasty [Suppl] 7:439-445
-
(1992)
J. Arthroplasty [Suppl]
, vol.7
, pp. 439-445
-
-
Matsuda, Y.1
Yamamuro, T.2
Kasai, R.3
-
21
-
-
0343851164
-
Extensive metallosis and necrosis in failed prostheses with cemented titanium-alloy stems and ceramic heads
-
1:STN:280:DC%2BD3c3ntFaktA%3D%3D
-
Milosev L, Antolic V, Minovic A, et al (2000) Extensive metallosis and necrosis in failed prostheses with cemented titanium-alloy stems and ceramic heads. J Bone Joint Surg Br 82:352-357 1:STN:280:DC%2BD3c3ntFaktA%3D%3D
-
(2000)
J. Bone Joint Surg. Br.
, vol.82
, pp. 352-357
-
-
Milosev, L.1
Antolic, V.2
Minovic, A.3
-
22
-
-
0028302626
-
A histologic study of soft-tissue reactions to spinal implants
-
1:STN:280:ByuA3sjitlQ%3D
-
Mody DR, Esses SI, Heggeness MH (1994) A histologic study of soft-tissue reactions to spinal implants. Spine 19:1153-1156 1:STN:280:ByuA3sjitlQ%3D
-
(1994)
Spine
, vol.19
, pp. 1153-1156
-
-
Mody, D.R.1
Esses, S.I.2
Heggeness, M.H.3
-
23
-
-
0032055996
-
Multicycle mechanical performance of titanium and stainless steel transpedicular spine implants
-
1:STN:280:DyaK1c3isVajuw%3D%3D
-
Pienkowski D, Stephens GC, Doers TM, et al (1998) Multicycle mechanical performance of titanium and stainless steel transpedicular spine implants. Spine 23:782-788 1:STN:280:DyaK1c3isVajuw%3D%3D
-
(1998)
Spine
, vol.23
, pp. 782-788
-
-
Pienkowski, D.1
Stephens, G.C.2
Doers, T.M.3
-
24
-
-
0032849782
-
Atomic absorption spectrophotometry (AAS) for the evaluation of metallosis in prostheses and artificial organs: A new approach
-
10493562
-
Pierini G, Fini M, Giavaresi G, et al (1999) Atomic absorption spectrophotometry (AAS) for the evaluation of metallosis in prostheses and artificial organs: A new approach. Int J Artif Organs 22:522-527 10493562
-
(1999)
Int. J. Artif. Organs
, vol.22
, pp. 522-527
-
-
Pierini, G.1
Fini, M.2
Giavaresi, G.3
-
25
-
-
0028838628
-
In vivo corrosion of cobalt-chromium and titanium wear particles
-
1:STN:280:BymD2sjgsVw%3D
-
Shahgaldi BF, Heatly FW, Dewar A, et al (1995) In vivo corrosion of cobalt-chromium and titanium wear particles. J Bone Joint Surg Br 77:962-966 1:STN:280:BymD2sjgsVw%3D
-
(1995)
J. Bone Joint Surg. Br.
, vol.77
, pp. 962-966
-
-
Shahgaldi, B.F.1
Heatly, F.W.2
Dewar, A.3
-
26
-
-
0030339091
-
Metal implants and surface reactions
-
Steinemann SG (1996) Metal implants and surface reactions. Injury 27 [Suppl 3]:SC16-22
-
(1996)
Injury
, vol.27
, Issue.SUPPL. 3
-
-
Steinemann, S.G.1
-
27
-
-
0343581296
-
Changes in the unfused lumbar spine in the patient with idiopatihic scoliosis: A 5- to 9-year assessment following Cotrel-Dubousset instrumentation
-
1:STN:280:ByiB3s7ltlY%3D
-
Takahashi S, Delecrin J, Passuti N (1997) Changes in the unfused lumbar spine in the patient with idiopatihic scoliosis: A 5- to 9-year assessment following Cotrel-Dubousset instrumentation. Spine 22:517-524 1:STN:280:ByiB3s7ltlY%3D
-
(1997)
Spine
, vol.22
, pp. 517-524
-
-
Takahashi, S.1
Delecrin, J.2
Passuti, N.3
-
28
-
-
0035399461
-
Intraspinal metallosis causing delayed neurological symptoms after spinal instrumentation surgery
-
1:STN:280:DC%2BD3MvgsV2rsQ%3D%3D
-
Takahashi S, Delecrin J, Passuti N (2001) Intraspinal metallosis causing delayed neurological symptoms after spinal instrumentation surgery. Spine 26:1495-1499 1:STN:280:DC%2BD3MvgsV2rsQ%3D%3D
-
(2001)
Spine
, vol.26
, pp. 1495-1499
-
-
Takahashi, S.1
Delecrin, J.2
Passuti, N.3
-
29
-
-
0024328625
-
Aggressive granulamatous lesions in hip arthroplasty
-
1:STN:280:BiaA2MbksVM%3D
-
Tallroth K, Eskola A, Santavirta S, et al (1989) Aggressive granulamatous lesions in hip arthroplasty. J Bone Joint Surg Br 71:571-575 1:STN:280:BiaA2MbksVM%3D
-
(1989)
J. Bone Joint Surg. Br.
, vol.71
, pp. 571-575
-
-
Tallroth, K.1
Eskola, A.2
Santavirta, S.3
-
30
-
-
0033562411
-
Corrosion on an internal spinal fixator system
-
1:STN:280:DyaK1M3msFWrtQ%3D%3D
-
Vieweg U, van Roost D, Wolf HK, et al (1999) Corrosion on an internal spinal fixator system. Spine 24:946-951 1:STN:280:DyaK1M3msFWrtQ%3D%3D
-
(1999)
Spine
, vol.24
, pp. 946-951
-
-
Vieweg, U.1
van Roost, D.2
Wolf, H.K.3
-
31
-
-
0033134799
-
Metal debris from titanium spinal implants
-
1:STN:280:DyaK1M3lvFCqtA%3D%3D
-
Wang JC, Yu WD, Sandhu HS, et al (1999) Metal debris from titanium spinal implants. Spine 24:899-903 1:STN:280:DyaK1M3lvFCqtA%3D%3D
-
(1999)
Spine
, vol.24
, pp. 899-903
-
-
Wang, J.C.1
Yu, W.D.2
Sandhu, H.S.3
-
32
-
-
0029968750
-
Local tissue of the lumbar spine response to titanium plate-screw system
-
Xu R, Ebraheim NA, Nadaud MC, et al (1996) Local tissue of the lumbar spine response to titanium plate-screw system. Spine 21:81-84
-
(1996)
Spine
, vol.21
, pp. 81-84
-
-
Xu, R.1
Ebraheim, N.A.2
Nadaud, M.C.3
-
33
-
-
0028947124
-
Transpedicular fixation of the lumbar and lumbosacral spine with screws: Application of the Diapason system
-
1:STN:280:ByqA3svjtVQ%3D
-
Yanase M, Sakou T, Taketomi E, et al (1995) Transpedicular fixation of the lumbar and lumbosacral spine with screws: Application of the Diapason system. Paraplegia 33:216-218 1:STN:280:ByqA3svjtVQ%3D
-
(1995)
Paraplegia
, vol.33
, pp. 216-218
-
-
Yanase, M.1
Sakou, T.2
Taketomi, E.3
-
34
-
-
0031027419
-
Supression of osteoblast function by titanium particles
-
9010191
-
Yau J, Cs-zabo G, Jacobs JJ, et al (1997) Supression of osteoblast function by titanium particles. J Bone Joint Surg Am 79:107-112 9010191
-
(1997)
J. Bone Joint Surg. Am.
, vol.79
, pp. 107-112
-
-
Yau, J.1
Cs-zabo, G.2
Jacobs, J.J.3
|