메뉴 건너뛰기




Volumn 52, Issue 5, 2004, Pages 1005-1015

Automatic spatial and temporal temperature control for MR-guided focused ultrasound using fast 3D MR thermometry and multispiral trajectory of the focal point

Author keywords

Focused ultrasound; Interventional MRI; MR temperature mapping; Temperature control

Indexed keywords

AUTOMATION; HEAT CONDUCTION; PROPORTIONAL CONTROL SYSTEMS; TEMPERATURE CONTROL; THERMOMETERS; TISSUE; TRAJECTORIES; ULTRASONICS;

EID: 7544242319     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20280     Document Type: Article
Times cited : (110)

References (17)
  • 1
    • 0022395995 scopus 로고
    • Metabolic changes during and after hyperthermia
    • Streffer C. Metabolic changes during and after hyperthermia, Int J Hyperthermia 1985;1:305-319.
    • (1985) Int J Hyperthermia , vol.1 , pp. 305-319
    • Streffer, C.1
  • 4
    • 0642275626 scopus 로고    scopus 로고
    • Spatial and temporal control of trangene expression in vivo using a heat-sensitive promoter and MRI-guided focused ultrasound
    • Guilhon E, Voisin P, de Zwart JA, Quesson B, Salomir R, Maurange C et al. Spatial and temporal control of trangene expression in vivo using a heat-sensitive promoter and MRI-guided focused ultrasound J. Gene Med 2003;5:333-342.
    • (2003) J Gene Med , vol.5 , pp. 333-342
    • Guilhon, E.1    Voisin, P.2    De Zwart, J.A.3    Quesson, B.4    Salomir, R.5    Maurange, C.6
  • 7
    • 0029677201 scopus 로고    scopus 로고
    • A clinical, noninvasive, MR imaging-monitored ultrasound surgery method
    • Hynynen K, Freund WR, Cline HE, et al. A clinical, noninvasive, MR imaging-monitored ultrasound surgery method. Radiographics 1996;16:185-195.
    • (1996) Radiographics , vol.16 , pp. 185-195
    • Hynynen, K.1    Freund, W.R.2    Cline, H.E.3
  • 10
    • 0034087586 scopus 로고    scopus 로고
    • Hyperthermia by MR-guided focused ultrasound: Accurate temperature control based on fast MRI and a physical model of local energy deposition and heat conduction
    • Salomir R, Vimeux F, de Zwart J, Grenier N, Moonen CTW. Hyperthermia by MR-guided focused ultrasound: Accurate temperature control based on fast MRI and a physical model of local energy deposition and heat conduction. Magn Reson Med 2000;43:342-347.
    • (2000) Magn Reson Med , vol.43 , pp. 342-347
    • Salomir, R.1    Vimeux, F.2    De Zwart, J.3    Grenier, N.4    Moonen, C.T.W.5
  • 11
    • 0035088063 scopus 로고    scopus 로고
    • MR imaging-guided focused ultrasound surgery of fibroadenomas in the breast: A feasibility study
    • Hynynen K, Pomeroy O, Smith DN, et al. MR imaging-guided focused ultrasound surgery of fibroadenomas in the breast: A feasibility study. Radiology 2001;219:176-185.
    • (2001) Radiology , vol.219 , pp. 176-185
    • Hynynen, K.1    Pomeroy, O.2    Smith, D.N.3
  • 12
    • 0037372845 scopus 로고    scopus 로고
    • MR imaging-guided focused ultrasound surgery of uterine leiomyomas: A feasibility study
    • Tempany CM, Stewart EA, McDannold N, Quade BJ, Jolesz FA, Hynynen K. MR imaging-guided focused ultrasound surgery of uterine leiomyomas: A feasibility study. Radiology 2003;226(3):897-905.
    • (2003) Radiology , vol.226 , Issue.3 , pp. 897-905
    • Tempany, C.M.1    Stewart, E.A.2    McDannold, N.3    Quade, B.J.4    Jolesz, F.A.5    Hynynen, K.6
  • 13
    • 7144259739 scopus 로고    scopus 로고
    • Ultrasonically induced minimally invasive surgery
    • ter Haar G. Ultrasonically induced minimally invasive surgery. J Eur Med Urgence 1998;19:255-259.
    • (1998) J Eur Med Urgence , vol.19 , pp. 255-259
    • Ter Haar, G.1
  • 14
    • 0033808921 scopus 로고    scopus 로고
    • Local hyperthermia with MR-guided focused ultrasound: Spiral trajectory of the focal point optimized for temperature uniformity in the target region
    • Salomir R, Palussière J, Vimeux F, Moonen CTW et al. Local hyperthermia with MR-guided focused ultrasound: Spiral trajectory of the focal point optimized for temperature uniformity in the target region. J Magn Res Imaging 2000;12:571-583.
    • (2000) J Magn Res Imaging , vol.12 , pp. 571-583
    • Salomir, R.1    Palussière, J.2    Vimeux, F.3    Moonen, C.T.W.4
  • 15
    • 0037225633 scopus 로고    scopus 로고
    • Feasibility of MR-guided focused ultrasound with real-time temperature mapping and continuous sonication for ablation of VX2 carcinoma in rabbit thigh
    • Palussière J, Salomir R, Le Bail B, Fawaz R, Quesson B, Grenier N Moonen CT. Feasibility of MR-guided focused ultrasound with real-time temperature mapping and continuous sonication for ablation of VX2 carcinoma in rabbit thigh. Magn Res Med 2003;49:89-98.
    • (2003) Magn Res Med , vol.49 , pp. 89-98
    • Palussière, J.1    Salomir, R.2    Le Bail, B.3    Fawaz, R.4    Quesson, B.5    Grenier, N.6    Moonen, C.T.7
  • 17
    • 7544230585 scopus 로고    scopus 로고
    • On-line high order correction of PRF thermometry for the magnetic perturbation due to the motion of a FUS transducer
    • Salomir R, Denis de Senneville, Mougenot C, Moonen CTW. On-line high order correction of PRF thermometry for the magnetic perturbation due to the motion of a FUS transducer. MAGMA 2002;15(1):118.
    • (2002) MAGMA , vol.15 , Issue.1 , pp. 118
    • Salomir, R.1    De Senneville, D.2    Mougenot, C.3    Moonen, C.T.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.