메뉴 건너뛰기




Volumn 25, Issue 5, 2007, Pages 211-217

Influence of liquid crystal display monitors on observer performance for detection of diffuse pulmonary disease on chest radiographs

Author keywords

Lung, diagnosis; Lung, diffuse pulmonary disease; Observer performance; Radiography, digital; Thorax, radiography

Indexed keywords

ARTICLE; DIAGNOSTIC ACCURACY; DIFFUSE PULMONARY DISEASE; DIGITAL RADIOGRAPHY; HIGH RESOLUTION COMPUTER TOMOGRAPHY; HUMAN; ILLUMINATION; IMAGE ANALYSIS; INTERMETHOD COMPARISON; LIQUID CRYSTAL; LUMINANCE; LUNG DISEASE; MONITOR; OBSERVER BIAS; RADIOLOGIST; RECEIVER OPERATING CHARACTERISTIC; RELIABILITY; THORAX RADIOGRAPHY; ANALYSIS OF VARIANCE; INFORMATION PROCESSING; OBSERVER VARIATION; PATHOLOGY; RADIOGRAPHY; ROC CURVE;

EID: 34548068384     PISSN: 02882043     EISSN: 18625274     Source Type: Journal    
DOI: 10.1007/s11604-007-0126-6     Document Type: Article
Times cited : (8)

References (21)
  • 1
    • 0034879358 scopus 로고    scopus 로고
    • Detection of subtle pulmonary disease on CR chest images: Monochromatic CRT monitor vs color CRT monitor
    • S Iwano T Ishigaki K Shimamoto K Inamura T Maeda M Ikeda 2001 Detection of subtle pulmonary disease on CR chest images: monochromatic CRT monitor vs color CRT monitor Eur Radiol 11 59 64
    • (2001) Eur Radiol , vol.11 , pp. 59-64
    • Iwano, S.1    Ishigaki, T.2    Shimamoto, K.3    Inamura, K.4    Maeda, T.5    Ikeda, M.6
  • 2
    • 0032849474 scopus 로고    scopus 로고
    • Glenohumeral relationships during physiologic shoulder motion and stress testing: Initial experience with open MR imaging and active imaging-plane registration
    • CF Beaulieu DK Hodge AG Bergman K Butts BL Daniel CL Napper 1999 Glenohumeral relationships during physiologic shoulder motion and stress testing: initial experience with open MR imaging and active imaging-plane registration Radiology 212 699 705
    • (1999) Radiology , vol.212 , pp. 699-705
    • Beaulieu, C.F.1    Hodge, D.K.2    Bergman, A.G.3    Butts, K.4    Daniel, B.L.5    Napper, C.L.6
  • 4
    • 0034943044 scopus 로고    scopus 로고
    • Urinary calculi on computed radiography: Comparison of observer performance with hard-copy versus soft-copy images on different viewer systems
    • AY Kim KS Cho KS Song JH Kim JG Kim HK Ha 2001 Urinary calculi on computed radiography: comparison of observer performance with hard-copy versus soft-copy images on different viewer systems Am J Roentgenol 177 331 5
    • (2001) Am J Roentgenol , vol.177 , pp. 331-5
    • Kim, A.Y.1    Cho, K.S.2    Song, K.S.3    Kim, J.H.4    Kim, J.G.5    Ha, H.K.6
  • 5
    • 1642538221 scopus 로고    scopus 로고
    • AAPM/RSNA tutorial on equipment selection: PACS equipment overview: General guidelines for purchasing and acceptance testing of PACS equipment
    • E Samei JA Seibert K Andriole A Badano J Crawford B Reiner 2004 AAPM/RSNA tutorial on equipment selection: PACS equipment overview: general guidelines for purchasing and acceptance testing of PACS equipment Radiographics 24 313 34
    • (2004) Radiographics , vol.24 , pp. 313-34
    • Samei, E.1    Seibert, J.A.2    Andriole, K.3    Badano, A.4    Crawford, J.5    Reiner, B.6
  • 7
    • 2542602946 scopus 로고    scopus 로고
    • AAPM/RSNA tutorial on equipment selection: PACS equipment overview: Display systems
    • A Badano 2004 AAPM/RSNA tutorial on equipment selection: PACS equipment overview: display systems Radiographics 24 879 89
    • (2004) Radiographics , vol.24 , pp. 879-89
    • Badano, A.1
  • 8
    • 12344299356 scopus 로고    scopus 로고
    • Detectability of catheters on bedside chest radiographs: Comparison between liquid crystal display and high-resolution cathode-ray tube monitors
    • M Scharitzer M Prokop M Weber M Fuchsjager E Oschatz C Schaefer-Prokop 2005 Detectability of catheters on bedside chest radiographs: comparison between liquid crystal display and high-resolution cathode-ray tube monitors Radiology 234 611 6
    • (2005) Radiology , vol.234 , pp. 611-6
    • Scharitzer, M.1    Prokop, M.2    Weber, M.3    Fuchsjager, M.4    Oschatz, E.5    Schaefer-Prokop, C.6
  • 9
    • 15044349827 scopus 로고    scopus 로고
    • SCAR R&D Symposium 2003: Comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease
    • S Langer B Bartholmai K Fetterly S Harmsen W Ryan B Erickson 2004 SCAR R&D Symposium 2003: comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease J Digit Imaging 17 149 57
    • (2004) J Digit Imaging , vol.17 , pp. 149-57
    • Langer, S.1    Bartholmai, B.2    Fetterly, K.3    Harmsen, S.4    Ryan, W.5    Erickson, B.6
  • 10
    • 0141618366 scopus 로고    scopus 로고
    • Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography
    • G Pärtan R Mayrhofer M Urban M Wassipaul L Pichler W Hruby 2003 Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography Eur Radiol 13 2397 401
    • (2003) Eur Radiol , vol.13 , pp. 2397-401
    • Pärtan, G.1    Mayrhofer, R.2    Urban, M.3    Wassipaul, M.4    Pichler, L.5    Hruby, W.6
  • 11
    • 1542788005 scopus 로고    scopus 로고
    • Liquid-crystal display monitors and cathode-ray tube monitors: A comparison of observer performance in the detection of small solitary pulmonary nodules
    • SA Hwang JB Seo BK Choi KH Do SM Ko SH Lee 2003 Liquid-crystal display monitors and cathode-ray tube monitors: a comparison of observer performance in the detection of small solitary pulmonary nodules Korean Journal of Radiology 4 153 6
    • (2003) Korean Journal of Radiology , vol.4 , pp. 153-6
    • Hwang, S.A.1    Seo, J.B.2    Choi, B.K.3    Do, K.H.4    Ko, S.M.5    Lee, S.H.6
  • 12
    • 16244423301 scopus 로고    scopus 로고
    • Flat-panel display (LCD) versus high-resolution gray-scale display (CRT) for chest radiography: An observer preference study
    • C Balassy M Prokop M Weber J Sailer CJ Herold C Schaefer-Prokop 2005 Flat-panel display (LCD) versus high-resolution gray-scale display (CRT) for chest radiography: an observer preference study AJR Am J Roentgenol 184 752 6
    • (2005) AJR Am J Roentgenol , vol.184 , pp. 752-6
    • Balassy, C.1    Prokop, M.2    Weber, M.3    Sailer, J.4    Herold, C.J.5    Schaefer-Prokop, C.6
  • 13
    • 33746641335 scopus 로고    scopus 로고
    • The influence of liquid crystal display (LCD) monitors on observer performance for the detection of nodular lesions on chest radiographs
    • H Usami M Ikeda T Ishigaki H Fukushima K Shimamoto 2006 The influence of liquid crystal display (LCD) monitors on observer performance for the detection of nodular lesions on chest radiographs Eur Radiol 16 726 32
    • (2006) Eur Radiol , vol.16 , pp. 726-32
    • Usami, H.1    Ikeda, M.2    Ishigaki, T.3    Fukushima, H.4    Shimamoto, K.5
  • 14
    • 0029812535 scopus 로고    scopus 로고
    • Subtle pulmonary disease: Detection with computed radiography versus conventional chest radiography
    • T Ishigaki T Endo M Ikeda M Kono S Yoshida J Ikezoe 1996 Subtle pulmonary disease: detection with computed radiography versus conventional chest radiography Radiology 201 51 60
    • (1996) Radiology , vol.201 , pp. 51-60
    • Ishigaki, T.1    Endo, T.2    Ikeda, M.3    Kono, M.4    Yoshida, S.5    Ikezoe, J.6
  • 16
    • 0029992390 scopus 로고    scopus 로고
    • Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs
    • T Kobayashi XW Xu H MacMahon CE Metz K Doi 1996 Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs Radiology 199 843 8
    • (1996) Radiology , vol.199 , pp. 843-8
    • Kobayashi, T.1    Xu, X.W.2    MacMahon, H.3    Metz, C.E.4    Doi, K.5
  • 17
    • 0032525017 scopus 로고    scopus 로고
    • Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data
    • CE Metz BA Herman JH Shen 1998 Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data Stat Med 17 1033 53
    • (1998) Stat Med , vol.17 , pp. 1033-53
    • Metz, C.E.1    Herman, B.A.2    Shen, J.H.3
  • 18
    • 0026664983 scopus 로고
    • Receiver operating characteristic rating analysis: Generalization to the population of readers and patients with the jackknife method
    • DD Dorfman KS Berbaum CE Metz 1992 Receiver operating characteristic rating analysis: generalization to the population of readers and patients with the jackknife method Invest Radiol 27 723 31
    • (1992) Invest Radiol , vol.27 , pp. 723-31
    • Dorfman, D.D.1    Berbaum, K.S.2    Metz, C.E.3
  • 19
    • 33750717075 scopus 로고    scopus 로고
    • Comparison of LCD and CRT monitors for detection of pulmonary nodules and interstitial lung diseases on digital chest radiographs by using receiver operating characteristic analysis
    • McCormick Place, Chicago
    • Ikeda R, Katsuragawa S, Shimonobu T, Hashida M, Yamashita Y, Doi K. Comparison of LCD and CRT monitors for detection of pulmonary nodules and interstitial lung diseases on digital chest radiographs by using receiver operating characteristic analysis. In: RSNA '04. McCormick Place, Chicago, 2004, p. 181
    • (2004) RSNA '04 , pp. 181
    • Ikeda, R.1    Katsuragawa, S.2    Shimonobu, T.3    Hashida, M.4    Yamashita, Y.5    Doi, K.6
  • 21
    • 0033856927 scopus 로고    scopus 로고
    • Sample size tables for receiver operating characteristic studies
    • NA Obuchowski 2000 Sample size tables for receiver operating characteristic studies AJR Am J Roentgenol 175 603 8
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 603-8
    • Obuchowski, N.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.