메뉴 건너뛰기




Volumn 16, Issue 3, 2006, Pages 726-732

The influence of liquid crystal display (LCD) monitors on observer performance for the detection of nodular lesions on chest radiographs

Author keywords

Lung, diagnosis; Lung, nodule; Observer performance; Radiography, digital; Thorax, radiography

Indexed keywords

ARTICLE; CONTROLLED STUDY; EQUIPMENT DESIGN; FEMALE; HUMAN; IMAGE ANALYSIS; INTERMETHOD COMPARISON; LIQUID CRYSTAL; LUMINANCE; LUNG CANCER; LUNG NODULE; MAJOR CLINICAL STUDY; MALE; MONITOR; OBSERVER VARIATION; PRIORITY JOURNAL; RADIOLOGIST; RECEIVER OPERATING CHARACTERISTIC; RELIABILITY; STATISTICAL SIGNIFICANCE; THORAX RADIOGRAPHY;

EID: 33746641335     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-005-0030-3     Document Type: Article
Times cited : (24)

References (27)
  • 1
    • 0034879358 scopus 로고    scopus 로고
    • Detection of subtle pulmonary disease on CR chest images: Monochromatic CRT monitor vs color CRT monitor
    • Iwano S, Ishigaki T, Shimamoto K et al (2001) Detection of subtle pulmonary disease on CR chest images: Monochromatic CRT monitor vs color CRT monitor. Eur Radiol 11:59-64
    • (2001) Eur Radiol , vol.11 , pp. 59-64
    • Iwano, S.1    Ishigaki, T.2    Shimamoto, K.3
  • 2
    • 0032742141 scopus 로고    scopus 로고
    • PACS in sonography: Accuracy of interpretation using film compared with monitor display. Picture archiving and communication systems
    • Hertzberg BS, Kliewer MA, Paulson EK et al (1999) PACS in sonography: accuracy of interpretation using film compared with monitor display. Picture archiving and communication systems. Am J Roentgenol 173:1175-1179
    • (1999) Am J Roentgenol , vol.173 , pp. 1175-1179
    • Hertzberg, B.S.1    Kliewer, M.A.2    Paulson, E.K.3
  • 3
    • 0029812535 scopus 로고    scopus 로고
    • Subtle pulmonary disease: Detection with computed radiography versus conventional chest radiography
    • Ishigaki T, Endo T, Ikeda M et al (1996) Subtle pulmonary disease: detection with computed radiography versus conventional chest radiography. Radiology 201:51-60
    • (1996) Radiology , vol.201 , pp. 51-60
    • Ishigaki, T.1    Endo, T.2    Ikeda, M.3
  • 4
    • 0029074546 scopus 로고
    • Filmless musculoskeletal radiology: Why is it taking so long?
    • Wilson AJ (1995) Filmless musculoskeletal radiology: Why is it taking so long? Am J Roentgenol 165:105-107
    • (1995) Am J Roentgenol , vol.165 , pp. 105-107
    • Wilson, A.J.1
  • 5
    • 0026570759 scopus 로고
    • Receiver-operating-characteristic study of chest radiographs in children: Digital hard-copy film vs 2K × 2K soft-copy images
    • Razavi M, Sayre JW, Taira RK et al (1992) Receiver-operating-characteristic study of chest radiographs in children: Digital hard-copy film vs 2K × 2K soft-copy images. Am J Roentgenol 158:443-448
    • (1992) Am J Roentgenol , vol.158 , pp. 443-448
    • Razavi, M.1    Sayre, J.W.2    Taira, R.K.3
  • 6
    • 0026030734 scopus 로고
    • Primary CT diagnosis of abdominal masses in a PACS environment
    • Straub WH, Gur D, Good WF et al (1991) Primary CT diagnosis of abdominal masses in a PACS environment. Radiology 178:739-743
    • (1991) Radiology , vol.178 , pp. 739-743
    • Straub, W.H.1    Gur, D.2    Good, W.F.3
  • 7
    • 0025272377 scopus 로고
    • Receiver operating characteristic analysis of chest image interpretation with conventional, laser-printed, and high-resolution workstation images
    • Slasky BS, Gur D, Good WF et al (1990) Receiver operating characteristic analysis of chest image interpretation with conventional, laser-printed, and high-resolution workstation images. Radiology 174:775-780
    • (1990) Radiology , vol.174 , pp. 775-780
    • Slasky, B.S.1    Gur, D.2    Good, W.F.3
  • 8
    • 0025320232 scopus 로고
    • Display of CT studies on a two-screen electronic workstation versus a film panel alternator: Sensitivity and efficiency among radiologists
    • Foley WD, Jacobson DR, Taylor AJ et al (1990) Display of CT studies on a two-screen electronic workstation versus a film panel alternator: sensitivity and efficiency among radiologists. Radiology 174:769-773
    • (1990) Radiology , vol.174 , pp. 769-773
    • Foley, W.D.1    Jacobson, D.R.2    Taylor, A.J.3
  • 9
    • 0024502978 scopus 로고
    • Comparison of 2,048-line digital display formats and conventional radiographs: An ROC study
    • Hayrapetian A, Aberle DR, Huang HK et al (1989) Comparison of 2,048-line digital display formats and conventional radiographs: An ROC study. Am J Roentgenol 152:1113-1118
    • (1989) Am J Roentgenol , vol.152 , pp. 1113-1118
    • Hayrapetian, A.1    Aberle, D.R.2    Huang, H.K.3
  • 10
    • 0022640460 scopus 로고
    • Digital and conventional chest images: Observer performance with film digital radiography system
    • Goodman LR, Foley WD, Wilson CR, Rimm AA, Lawson TL (1986) Digital and conventional chest images: Observer performance with film digital radiography system. Radiology 158:27-33
    • (1986) Radiology , vol.158 , pp. 27-33
    • Goodman, L.R.1    Foley, W.D.2    Wilson, C.R.3    Rimm, A.A.4    Lawson, T.L.5
  • 11
    • 0033228448 scopus 로고    scopus 로고
    • High-fidelity electronic display of digital radiographs
    • Flynn MJ, Kanicki J, Badano A, Eyler WR (1999) High-fidelity electronic display of digital radiographs. RadioGraphics 19:1653-1669
    • (1999) RadioGraphics , vol.19 , pp. 1653-1669
    • Flynn, M.J.1    Kanicki, J.2    Badano, A.3    Eyler, W.R.4
  • 12
    • 0034943044 scopus 로고    scopus 로고
    • Urinary calculi on computed radiography: Comparison of observer performance with hard-copy versus soft-copy images on different viewer systems
    • Kim AY, Cho KS, Song KS, Kim JH, Kim JG, Ha HK (2001) Urinary calculi on computed radiography: Comparison of observer performance with hard-copy versus soft-copy images on different viewer systems. Am J Roentgenol 177:331-335
    • (2001) Am J Roentgenol , vol.177 , pp. 331-335
    • Kim, A.Y.1    Cho, K.S.2    Song, K.S.3    Kim, J.H.4    Kim, J.G.5    Ha, H.K.6
  • 13
    • 1642538221 scopus 로고    scopus 로고
    • AAPM/RSNA Tutorial on equipment selection: PACS equipment overview: General guidelines for purchasing and acceptance testing of PACS equipment
    • Samei E, Seibert JA, Andriole K et al (2004) AAPM/RSNA Tutorial on equipment selectionG PACS equipment overview: general guidelines for purchasing and acceptance testing of PACS equipment. RadioGraphics 24:313-334
    • (2004) RadioGraphics , vol.24 , pp. 313-334
    • Samei, E.1    Seibert, J.A.2    Andriole, K.3
  • 14
    • 1842731028 scopus 로고    scopus 로고
    • Importance and effects of altered workplace ergonomics in modern radiology suites
    • Harisinghani MG, Blake MA, Saksena M et al (2004) Importance and effects of altered workplace ergonomics in modern radiology suites. RadioGraphics 24:615-627
    • (2004) RadioGraphics , vol.24 , pp. 615-627
    • Harisinghani, M.G.1    Blake, M.A.2    Saksena, M.3
  • 15
    • 2542602946 scopus 로고    scopus 로고
    • AAPM/RSNA Tutorial on equipment selection: PACS equipment overview: Display systems
    • Badano A (2004) AAPM/RSNA Tutorial on equipment selection: PACS equipment overview: Display systems. RadioGraphics 24:879-889
    • (2004) RadioGraphics , vol.24 , pp. 879-889
    • Badano, A.1
  • 16
    • 12344299356 scopus 로고    scopus 로고
    • Detectability of catheters on bedside chest radiographs: Comparison between liquid crystal display and high-resolution cathode-ray tube monitors
    • Scharitzer M, Prokop M, Weber M, Fuchsjager M, Oschatz E, Schaefer-Prokop C (2005) Detectability of catheters on bedside chest radiographs: Comparison between liquid crystal display and high-resolution cathode-ray tube monitors. Radiology 234:611-616
    • (2005) Radiology , vol.234 , pp. 611-616
    • Scharitzer, M.1    Prokop, M.2    Weber, M.3    Fuchsjager, M.4    Oschatz, E.5    Schaefer-Prokop, C.6
  • 17
    • 15044349827 scopus 로고    scopus 로고
    • SCAR R&D Symposium 2003: Comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease
    • Langer S, Bartholmai B, Fetterly K et al (2004) SCAR R&D Symposium 2003: Comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease. J Digit Imaging 17:149-157
    • (2004) J Digit Imaging , vol.17 , pp. 149-157
    • Langer, S.1    Bartholmai, B.2    Fetterly, K.3
  • 18
    • 0141618366 scopus 로고    scopus 로고
    • Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography
    • Partan G, Mayrhofer R, Urban M, Wassipaul M, Pichler L, Hruby W (2003) Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography. Eur Radiol 13:2397-2401
    • (2003) Eur Radiol , vol.13 , pp. 2397-2401
    • Partan, G.1    Mayrhofer, R.2    Urban, M.3    Wassipaul, M.4    Pichler, L.5    Hruby, W.6
  • 19
    • 0033986483 scopus 로고    scopus 로고
    • Development of a digital image database for chest radiographs with and without a lung nodule: Receiver operating characteristic analysis of radiologists' detection of pulmonary nodules
    • Shiraishi J, Katsuragawa S, Ikezoe J et al (2000) Development of a digital image database for chest radiographs with and without a lung nodule: Receiver operating characteristic analysis of radiologists' detection of pulmonary nodules. Am J Roentgenol 174:71-74
    • (2000) Am J Roentgenol , vol.174 , pp. 71-74
    • Shiraishi, J.1    Katsuragawa, S.2    Ikezoe, J.3
  • 20
    • 0029992390 scopus 로고    scopus 로고
    • Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs
    • Kobayashi T, Xu XW, MacMahon H, Metz CE, Doi K (1996) Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs. Radiology 199:843-848
    • (1996) Radiology , vol.199 , pp. 843-848
    • Kobayashi, T.1    Xu, X.W.2    MacMahon, H.3    Metz, C.E.4    Doi, K.5
  • 22
    • 0032525017 scopus 로고    scopus 로고
    • Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data
    • Metz CE, Herman BA, Shen JH (1998) Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data. Stat Med 17:1033-1053
    • (1998) Stat Med , vol.17 , pp. 1033-1053
    • Metz, C.E.1    Herman, B.A.2    Shen, J.H.3
  • 23
    • 0026664983 scopus 로고
    • Receiver operating characteristic rating analysis: Generalization to the population of readers and patients with the jackknife method
    • Dorfman DD, Berbaum KS, Metz CE (1992) Receiver operating characteristic rating analysis: Generalization to the population of readers and patients with the jackknife method. Invest Radiol 27:723-731
    • (1992) Invest Radiol , vol.27 , pp. 723-731
    • Dorfman, D.D.1    Berbaum, K.S.2    Metz, C.E.3
  • 24
    • 0031111487 scopus 로고    scopus 로고
    • Dorfman-Berbaum-Metz method for statistical analysis of multireader, multimodality receiver operating characteristic data: Validation with computer simulation
    • Roe CA, Metz CE (1997) Dorfman-Berbaum-Metz method for statistical analysis of multireader, multimodality receiver operating characteristic data: Validation with computer simulation. Acad Radiol 4:298-303
    • (1997) Acad Radiol , vol.4 , pp. 298-303
    • Roe, C.A.1    Metz, C.E.2
  • 25
    • 0003480765 scopus 로고    scopus 로고
    • Computer-assisted research design and analysis
    • Allyn and Bacon, Boston, UK
    • Tabachnick BG, Fidell LS (2001) Computer-assisted research design and analysis. Allyn and Bacon, Boston, UK
    • (2001)
    • Tabachnick, B.G.1    Fidell, L.S.2
  • 26
    • 0003542250 scopus 로고
    • Multiple comparison procedures
    • John Wiley & Sons, New York
    • Hochberg Y, Tamhane AC (1987) Multiple comparison procedures. John Wiley & Sons, New York
    • (1987)
    • Hochberg, Y.1    Tamhane, A.C.2
  • 27
    • 0842302446 scopus 로고    scopus 로고
    • Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography
    • Sund P, Båth M, Kheddache S, Månsson LG (2004) Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography. Eur Radiol 14:48-58
    • (2004) Eur Radiol , vol.14 , pp. 48-58
    • Sund, P.1    Båth, M.2    Kheddache, S.3    Månsson, L.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.