메뉴 건너뛰기




Volumn 9, Issue 2, 2007, Pages 100-111

Ultrastructure of the interface between titanium and surrounding tissue in rat tibiae - A comparison study on titanium-coated and -uncoated plastic implants

Author keywords

Osseointegration; Plastic implant; Rat; Tissue implant interface; Titanium coating; Ultrastructure

Indexed keywords

ACRYLIC ACID RESIN; BIOMATERIAL; TITANIUM;

EID: 34547375088     PISSN: 15230899     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2007.00032.x     Document Type: Article
Times cited : (20)

References (40)
  • 2
    • 0001880006 scopus 로고    scopus 로고
    • Osseointegration: Biotechnological perspective and clinical modality
    • Brånemark P.I., Rydevik B.L., Skalak R., eds. Chicago, IL: Quintessence In: Brånemark P.I., Rydevik B.L., Skalak R., eds. Chicago, IL: Quintessence
    • Brånemark PI. Osseointegration: biotechnological perspective and clinical modality. In : Brånemark PI, Rydevik BL, Skalak R, eds. Osseointegration in skeletal reconstruction and joint replacement. Chicago, IL : Quintessence, 1997 : 1 24.
    • (1997) Osseointegration in Skeletal Reconstruction and Joint Replacement. , pp. 1-24
  • 3
    • 0019435541 scopus 로고
    • Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man
    • Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand 1981 52 : 155 170.
    • (1981) Acta Orthop Scand , vol.52 , pp. 155-170
    • Albrektsson, T.1    Brånemark, P.I.2    Hansson, H.A.3    Lindström, J.4
  • 4
    • 0023336356 scopus 로고
    • Bone-metal interface in osseointegration
    • Albrektsson T, Jacobsson M. Bone-metal interface in osseointegration. J Prosthet Dent 1987 57 : 597 607.
    • (1987) J Prosthet Dent , vol.57 , pp. 597-607
    • Albrektsson, T.1    Jacobsson, M.2
  • 5
    • 0023472755 scopus 로고
    • Interface mechanics and histology of titanium and hydroxyapatite-coated titanium for dental implant applications
    • Cook SD, Kay JF, Thomas KA, Jarcho M. Interface mechanics and histology of titanium and hydroxyapatite-coated titanium for dental implant applications. Int J Oral Maxillofac Implants 1987 2 : 15 22.
    • (1987) Int J Oral Maxillofac Implants , vol.2 , pp. 15-22
    • Cook, S.D.1    Kay, J.F.2    Thomas, K.A.3    Jarcho, M.4
  • 6
    • 0023302919 scopus 로고
    • Integration of screw implants in the rabbit: A 1-yr follow-up of removal torque of titanium implants
    • Johansson C, Albrektsson T. Integration of screw implants in the rabbit: a 1-yr follow-up of removal torque of titanium implants. Int J Oral Maxillofac Implants 1987 2 : 69 75.
    • (1987) Int J Oral Maxillofac Implants , vol.2 , pp. 69-75
    • Johansson, C.1    Albrektsson, T.2
  • 10
    • 33644863108 scopus 로고    scopus 로고
    • The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model
    • Shalabi MM, Wolke JGC, Jansen JA. The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model. Clin Oral Implants Res 2006 17 : 172 178.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 172-178
    • Shalabi, M.M.1    Wolke, J.G.C.2    Jansen, J.A.3
  • 11
    • 34547305979 scopus 로고    scopus 로고
    • Biological and biomechanical evaluation of interface reaction at conical screw-type implants
    • Büchter A, Joos U, Wiesmann HP, Seper L, Meyer U. Biological and biomechanical evaluation of interface reaction at conical screw-type implants. Head & Face Medicine 2006 2 : 5. http://www.head-face-med.com/content/pdf/ 1746-160X-2-5.pdf.
    • (2006) Head & Face Medicine , vol.2 , Issue.5
    • Büchter, A.1    Joos, U.2    Wiesmann, H.P.3    Seper, L.4    Meyer, U.5
  • 12
    • 0026826756 scopus 로고
    • A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone
    • Sennerby L, Thomsen P, Ericson LE. A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. Int J Oral Maxillofac Implants 1992 7 : 62 71.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 62-71
    • Sennerby, L.1    Thomsen, P.2    Ericson, L.E.3
  • 13
    • 0342601513 scopus 로고    scopus 로고
    • Biomechanical characterization of osseointegration during healing: An experimental in vivo study in the rat
    • Ö
    • Brånemark R, Ö hrnell LO, Nilsson P, Thomsen P. Biomechanical characterization of osseointegration during healing: an experimental in vivo study in the rat. Biomaterials 1997 18 : 969 978.
    • (1997) Biomaterials , vol.18 , pp. 969-978
    • Brånemark, R.1    Hrnell, L.O.2    Nilsson, P.3    Thomsen, P.4
  • 14
    • 0025900565 scopus 로고
    • Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs
    • Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mat Res 1991 25 : 889 902.
    • (1991) J Biomed Mat Res , vol.25 , pp. 889-902
    • Buser, D.1    Schenk, R.K.2    Steinemann, S.3    Fiorellini, J.P.4    Fox, C.H.5    Stich, H.6
  • 15
    • 0030110849 scopus 로고    scopus 로고
    • Bone response to surface-modified titanium implants: Studies on the early tissue response to machined and electropolished implants with different oxide thicknesses
    • Larsson C, Thomsen P, Aronsson BO, et al. Bone response to surface-modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thicknesses. Biomaterials 1996 17 : 605 616.
    • (1996) Biomaterials , vol.17 , pp. 605-616
    • Larsson, C.1    Thomsen, P.2    Aronsson, B.O.3
  • 16
    • 0026300431 scopus 로고
    • Histomorphometric studies of hydroxyapatite-coated and uncoated CP titanium threaded implants in bone
    • Gottlander M, Albrektsson T. Histomorphometric studies of hydroxyapatite-coated and uncoated CP titanium threaded implants in bone. Int J Oral Maxillofac Implants 1991 6 : 399 404.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 399-404
    • Gottlander, M.1    Albrektsson, T.2
  • 17
    • 0029786416 scopus 로고    scopus 로고
    • Effect of HA coating on the long-term survival of dental implant: A review of the literature
    • Kido H, Saha S. Effect of HA coating on the long-term survival of dental implant: a review of the literature. J Long Term Eff Med Implants 1996 6 : 119 133.
    • (1996) J Long Term Eff Med Implants , vol.6 , pp. 119-133
    • Kido, H.1    Saha, S.2
  • 19
    • 0020693527 scopus 로고
    • Electron microscopic analysis of the bone-titanium interface
    • Linder L, Albrektsson T, Brånemark PI, et al. Electron microscopic analysis of the bone-titanium interface. Acta Orthop Scand 1983 54 : 45 52.
    • (1983) Acta Orthop Scand , vol.54 , pp. 45-52
    • Linder, L.1    Albrektsson, T.2    Brånemark, P.I.3
  • 20
    • 0022974519 scopus 로고
    • An ultrastructural characterization of the interface between bone and sputtered titanium or stainless surfaces
    • Albrektsson T, Hansson HA. An ultrastructural characterization of the interface between bone and sputtered titanium or stainless surfaces. Biomaterials 1986 7 : 201 205.
    • (1986) Biomaterials , vol.7 , pp. 201-205
    • Albrektsson, T.1    Hansson, H.A.2
  • 21
    • 0026815484 scopus 로고
    • Light and transmission electron microscopy of the intact interfaces between non-submerged titanium-coated epoxy resin implants and bone or gingiva
    • Listgarten MA, Buser D, Steinemann SG, Donath K, Lang NP, Weber HP. Light and transmission electron microscopy of the intact interfaces between non-submerged titanium-coated epoxy resin implants and bone or gingiva. J Dent Res 1992 71 : 364 371.
    • (1992) J Dent Res , vol.71 , pp. 364-371
    • Listgarten, M.A.1    Buser, D.2    Steinemann, S.G.3    Donath, K.4    Lang, N.P.5    Weber, H.P.6
  • 22
    • 0030425257 scopus 로고    scopus 로고
    • An ultrastructural study of the bone-titanium interface using pure titanium-coated plastic and pure titanium rod implants
    • Ayukawa Y, Takeshita F, Inoue T, et al. An ultrastructural study of the bone-titanium interface using pure titanium-coated plastic and pure titanium rod implants. Acta Histochem Cytochem 1996 29 : 243 254.
    • (1996) Acta Histochem Cytochem , vol.29 , pp. 243-254
    • Ayukawa, Y.1    Takeshita, F.2    Inoue, T.3
  • 23
    • 0031602941 scopus 로고    scopus 로고
    • An immunocytochemical study for lysosomal cathepsins B and D related to the intracellular degradation of titanium at the bone-titanium interface
    • Ayukawa Y, Takeshita F, Yoshinari M, et al. An immunocytochemical study for lysosomal cathepsins B and D related to the intracellular degradation of titanium at the bone-titanium interface. J Periodontol 1998 69 : 62 68.
    • (1998) J Periodontol , vol.69 , pp. 62-68
    • Ayukawa, Y.1    Takeshita, F.2    Yoshinari, M.3
  • 24
    • 33645415036 scopus 로고    scopus 로고
    • An inverted observation technique for interactions between titanium oxide and cells on commercially pure titanium
    • Watazu A, Teraoka K, Kido H, et al. An inverted observation technique for interactions between titanium oxide and cells on commercially pure titanium. Key Eng Mater 2006 309 : 363 366.
    • (2006) Key Eng Mater , vol.309 , pp. 363-366
    • Watazu, A.1    Teraoka, K.2    Kido, H.3
  • 25
    • 0034132312 scopus 로고    scopus 로고
    • Tissue response to titanium implants in the rat maxilla: Ultrastructural and histochemical observations of the bone-titanium interface
    • Futami T, Fujii N, Ohnishi H, et al. Tissue response to titanium implants in the rat maxilla: ultrastructural and histochemical observations of the bone-titanium interface. J Periodontol 2000 71 : 287 298.
    • (2000) J Periodontol , vol.71 , pp. 287-298
    • Futami, T.1    Fujii, N.2    Ohnishi, H.3
  • 27
    • 34547334671 scopus 로고    scopus 로고
    • Formation and properties of transparent titanium thin films by DC magnetron sputtering for observing interactions between titanium and cells
    • Watazu A, Teraoka K, Kido H, et al. Formation and properties of transparent titanium thin films by DC magnetron sputtering for observing interactions between titanium and cells. Trans Mater Res Soc Jpn 2006 31 : 677 680.
    • (2006) Trans Mater Res Soc Jpn , vol.31 , pp. 677-680
    • Watazu, A.1    Teraoka, K.2    Kido, H.3
  • 28
  • 29
  • 30
    • 0036886029 scopus 로고    scopus 로고
    • Modulated bone matrix-related gene expression is associated with differences in interfacial strength of different implant surface roughness
    • Ogawa T, Sukotjo C, Nisimura I. Modulated bone matrix-related gene expression is associated with differences in interfacial strength of different implant surface roughness. Int J Prosthodont 2002 11 : 241 247.
    • (2002) Int J Prosthodont , vol.11 , pp. 241-247
    • Ogawa, T.1    Sukotjo, C.2    Nisimura, I.3
  • 31
    • 0038726948 scopus 로고    scopus 로고
    • Implant surface roughness affects osteoblast gene expression
    • Schneider GB, Perinpanayagam H, Clegg M, et al. Implant surface roughness affects osteoblast gene expression. J Dent Res 2003 82 : 372 376.
    • (2003) J Dent Res , vol.82 , pp. 372-376
    • Schneider, G.B.1    Perinpanayagam, H.2    Clegg, M.3
  • 32
    • 4544293605 scopus 로고    scopus 로고
    • The effect of different titanium and hydroxyapatite-coated dental implant surfaces on phenotypic expression of human bone-derived cell
    • Knabe C, Howlett CR, Klar F, Zreiqat H. The effect of different titanium and hydroxyapatite-coated dental implant surfaces on phenotypic expression of human bone-derived cell. J Biomed Mater Res 2004 71A : 98 107.
    • (2004) J Biomed Mater Res , vol.71 , pp. 98-107
    • Knabe, C.1    Howlett, C.R.2    Klar, F.3    Zreiqat, H.4
  • 33
    • 0027670706 scopus 로고
    • Early tissue response to titanium implants inserted in rabbit cortical bone. Part II: Ultrastructural observations
    • Sennerby L, Thomsen P, Ericson LE. Early tissue response to titanium implants inserted in rabbit cortical bone. Part II: ultrastructural observations. J Mater Sci Mater Med 1993 4 : 494 502.
    • (1993) J Mater Sci Mater Med , vol.4 , pp. 494-502
    • Sennerby, L.1    Thomsen, P.2    Ericson, L.E.3
  • 34
    • 0001495363 scopus 로고
    • Ultrastructure of the bone-titanium interface in rabbits
    • Sennerby L, Thomsen P, Ericson LE. Ultrastructure of the bone-titanium interface in rabbits. J Mater Sci Mater Med 1992 3 : 262 271.
    • (1992) J Mater Sci Mater Med , vol.3 , pp. 262-271
    • Sennerby, L.1    Thomsen, P.2    Ericson, L.E.3
  • 35
    • 0028753331 scopus 로고
    • Tissue response to titanium implants in the rat tibia: Ultrastructural, immunocytochemical and lectin-cytochemical characterization of the bone-titanium interface
    • Nanci A, McCarthy GF, Zalzal S, Clokie CML, Warshawsky H, McKee MD. Tissue response to titanium implants in the rat tibia: ultrastructural, immunocytochemical and lectin-cytochemical characterization of the bone-titanium interface. Cells and Materials 1994 4 : 1 30.
    • (1994) Cells and Materials , vol.4 , pp. 1-30
    • Nanci, A.1    McCarthy, G.F.2    Zalzal, S.3    Clokie, C.M.L.4    Warshawsky, H.5    McKee, M.D.6
  • 36
    • 0030130653 scopus 로고    scopus 로고
    • Light and microscopic studies of bone-titanium interface in the tibiae of young and mature rats
    • Murai K, Takeshita F, Ayukawa Y, Kiyoshima T, Suetugu T, Tanak T. Light and microscopic studies of bone-titanium interface in the tibiae of young and mature rats. J Biomed Mater Res 1996 30 : 523 533.
    • (1996) J Biomed Mater Res , vol.30 , pp. 523-533
    • Murai, K.1    Takeshita, F.2    Ayukawa, Y.3    Kiyoshima, T.4    Suetugu, T.5    Tanak, T.6
  • 39
    • 0002879007 scopus 로고
    • The role of implant surface geometry on mineralization in vivo and in vitro: A transmission and scanning electron microscopic study
    • Chehroudi B, Ratkay J, Brunette DM. The role of implant surface geometry on mineralization in vivo and in vitro: a transmission and scanning electron microscopic study. Cell and Materials 1992 2 : 89 104.
    • (1992) Cell and Materials , vol.2 , pp. 89-104
    • Chehroudi, B.1    Ratkay, J.2    Brunette, D.M.3
  • 40
    • 0026871124 scopus 로고
    • Visualization and initial characterization of the titanium boundary of the bone-implant interface of osseintegrated implants
    • Budd TW, Nagahara K, Bielat KL, Meenaghan MA, Schaaf NG. Visualization and initial characterization of the titanium boundary of the bone-implant interface of osseintegrated implants. Int J Oral Maxillofac Implants 1992 7 : 151 160.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 151-160
    • Budd, T.W.1    Nagahara, K.2    Bielat, K.L.3    Meenaghan, M.A.4    Schaaf, N.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.