메뉴 건너뛰기




Volumn 30, Issue 4, 1996, Pages 523-533

Light and electron microscopic studies of bone-titanium interface in the tibiae of young and mature rats

Author keywords

[No Author keywords available]

Indexed keywords

AMORPHOUS MATERIALS; BONE; CELLS; COLLAGEN; ELECTRON MICROSCOPY; IMPLANTS (SURGICAL); INTERFACES (MATERIALS); OPTICAL MICROSCOPY; TITANIUM;

EID: 0030130653     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(199604)30:4<523::AID-JBM11>3.0.CO;2-I     Document Type: Article
Times cited : (71)

References (16)
  • 1
    • 0020793302 scopus 로고
    • Structural aspects of the interface between tissue and titanium implants
    • H.-A. Hansson, T. Albrektsson, and P.-I. Branemark, "Structural aspects of the interface between tissue and titanium implants," J. Prosthet. Dent., 50, 108-113 (1983).
    • (1983) J. Prosthet. Dent. , vol.50 , pp. 108-113
    • Hansson, H.-A.1    Albrektsson, T.2    Branemark, P.-I.3
  • 2
    • 0022974519 scopus 로고
    • An ultrastructural characterization of the interface between bone and sputtered titanium or stainless steel surfaces
    • T. Albrektsson and H.-A. Hansson, "An ultrastructural characterization of the interface between bone and sputtered titanium or stainless steel surfaces," Biomaterials, 7, 201-205 (1986).
    • (1986) Biomaterials , vol.7 , pp. 201-205
    • Albrektsson, T.1    Hansson, H.-A.2
  • 3
    • 0024373648 scopus 로고
    • Osseointegration of metallic implants. 2. Transmission electron microscopy in the rabbit
    • L. Linder, K. Obrant, and G. Boivin, "Osseointegration of metallic implants. 2. Transmission electron microscopy in the rabbit," Acta. Orthop. Scand., 60, 135-139 (1989).
    • (1989) Acta. Orthop. Scand. , vol.60 , pp. 135-139
    • Linder, L.1    Obrant, K.2    Boivin, G.3
  • 4
    • 0027607314 scopus 로고
    • Osteogenesis at the dental implant interface: High-voltage electron microscopic and conventional transmission electron microscopic observations
    • D. E. Steflik, A. L. Sisk, G. R. Parr, L. K. Gardner, P. J. Hanes, F. T. Lake, D. J. Berkery, and P. Brewer, "Osteogenesis at the dental implant interface: High-voltage electron microscopic and conventional transmission electron microscopic observations," J. Biomed. Mater. Res., 27, 791-800 (1993).
    • (1993) J. Biomed. Mater. Res. , vol.27 , pp. 791-800
    • Steflik, D.E.1    Sisk, A.L.2    Parr, G.R.3    Gardner, L.K.4    Hanes, P.J.5    Lake, F.T.6    Berkery, D.J.7    Brewer, P.8
  • 5
  • 6
    • 0024586373 scopus 로고
    • Ultrastructural differences of the interface zone between bone and T16A14V or commercially pure titanium
    • C. Johansson, J. Lausmaa, M. Ask, H.-A. Hansson, and T. Albrektsson, "Ultrastructural differences of the interface zone between bone and T16A14V or commercially pure titanium," J. Biomed. Eng., 11, 3-8 (1989).
    • (1989) J. Biomed. Eng. , vol.11 , pp. 3-8
    • Johansson, C.1    Lausmaa, J.2    Ask, M.3    Hansson, H.-A.4    Albrektsson, T.5
  • 7
    • 0026815484 scopus 로고
    • Light and transmission electron microscopy of the intact interfaces between non-submerged titanium-coated epoxy resin implants and bone or gingiva
    • M. A. Listgarten, D. Buser, S. G. Steinemann, K. Donath, N. P. Lang, and H. P. Weber, "Light and transmission electron microscopy of the intact interfaces between non-submerged titanium-coated epoxy resin implants and bone or gingiva," J. Dent. Res., 71, 364-371 (1992).
    • (1992) J. Dent. Res. , vol.71 , pp. 364-371
    • Listgarten, M.A.1    Buser, D.2    Steinemann, S.G.3    Donath, K.4    Lang, N.P.5    Weber, H.P.6
  • 8
    • 0028753331 scopus 로고
    • Tissue response to titanium implants in the rat tibia: Ultrastructural, immunocytochemical and lectin-cytochemical characterization of the bone-titanium interface
    • A. Nanci, G. F. McCarthy, S. Zalzal, C. M. L. Clokie, H. Warshawsky, and M. D. McKee, "Tissue response to titanium implants in the rat tibia: Ultrastructural, immunocytochemical and lectin-cytochemical characterization of the bone-titanium interface," Cells Mater., 4, 1-30 (1994).
    • (1994) Cells Mater. , vol.4 , pp. 1-30
    • Nanci, A.1    McCarthy, G.F.2    Zalzal, S.3    Clokie, C.M.L.4    Warshawsky, H.5    McKee, M.D.6
  • 9
    • 0027409579 scopus 로고
    • The effect of aging on the healing of hydroxylapatite implants
    • T. Shirota, K. Ohno, K. Suzuki, and K. Michi, "The effect of aging on the healing of hydroxylapatite implants," J. Oral Maxillofac. Surg., 51, 51-56 (1993).
    • (1993) J. Oral Maxillofac. Surg. , vol.51 , pp. 51-56
    • Shirota, T.1    Ohno, K.2    Suzuki, K.3    Michi, K.4
  • 10
    • 0024825759 scopus 로고
    • An improved method using the bubble-free adhesion technique for preparation of semi-serial undecalcified histologic sections containing dental implants
    • A. Kihara, K. Morimoto, and T. Suetsugu, "An improved method using the bubble-free adhesion technique for preparation of semi-serial undecalcified histologic sections containing dental implants," J. Oral Implantol., 15, 87-94 (1989).
    • (1989) J. Oral Implantol. , vol.15 , pp. 87-94
    • Kihara, A.1    Morimoto, K.2    Suetsugu, T.3
  • 11
    • 0019807068 scopus 로고
    • The attachment mechanism of epithelial cells to titanium in vitro
    • T. R. L. Gould, D. M. Brunette, and L. Westbury, "The attachment mechanism of epithelial cells to titanium in vitro," J. Periodont. Res., 16, 611-616 (1981).
    • (1981) J. Periodont. Res. , vol.16 , pp. 611-616
    • Gould, T.R.L.1    Brunette, D.M.2    Westbury, L.3
  • 13
    • 0027670706 scopus 로고
    • Early tissue response to titanium implants inserted in rabbit cortical bone. Part II. Ultrastrucrural observations
    • L. Sennerby, P. Thomsen, and L. E. Ericson, "Early tissue response to titanium implants inserted in rabbit cortical bone. Part II. Ultrastrucrural observations," J. Mater. Sci. Mater. Med., 4, 494-502 (1993).
    • (1993) J. Mater. Sci. Mater. Med. , vol.4 , pp. 494-502
    • Sennerby, L.1    Thomsen, P.2    Ericson, L.E.3
  • 14
    • 0027588161 scopus 로고
    • Tissue reaction to alumina implants inserted into the tibiae of rats
    • F. Takeshita, K. Morimoto, and T. Suetsugu, "Tissue reaction to alumina implants inserted into the tibiae of rats," J. Biomed. Mater. Res., 27, 421-428 (1993).
    • (1993) J. Biomed. Mater. Res. , vol.27 , pp. 421-428
    • Takeshita, F.1    Morimoto, K.2    Suetsugu, T.3
  • 15
    • 0024985273 scopus 로고
    • Quantitative evaluation of human gingival epithelial cell attachment to implant surfaces in vitro
    • F. H. Kasten, K. Soileau, and R. M. Meffert, "Quantitative evaluation of human gingival epithelial cell attachment to implant surfaces in vitro," Int. J. Periodont. Restor. Dent., 10, 69-79 (1990).
    • (1990) Int. J. Periodont. Restor. Dent. , vol.10 , pp. 69-79
    • Kasten, F.H.1    Soileau, K.2    Meffert, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.