메뉴 건너뛰기




Volumn 27, Issue 3, 2007, Pages 577-590

The Role of Flow Cytometry in the Diagnosis of Paroxysmal Nocturnal Hemoglobinuria in the Clinical Laboratory

Author keywords

[No Author keywords available]

Indexed keywords

GLYCOSYLPHOSPHATIDYLINOSITOL;

EID: 34447558010     PISSN: 02722712     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cll.2007.05.012     Document Type: Review
Times cited : (32)

References (36)
  • 1
    • 34447580453 scopus 로고    scopus 로고
    • Hill A, Platts PJ, Smith A, et al. The incidence and prevalence of paroxysmal nocturnal hemoglobinuria (PNH) and survival of patients in Yorkshire [abstract 985]. In: Presented at the American society of hematology forty-eighth annual meeting. Orlando: Blood, 2006. p. 294a.
  • 2
    • 0028802443 scopus 로고
    • Natural history of paroxysmal nocturnal hemoglobinuria
    • Hillmen P., Lewis S.M., Bessler M., et al. Natural history of paroxysmal nocturnal hemoglobinuria. N Engl J Med 333 (1995) 1253-1258
    • (1995) N Engl J Med , vol.333 , pp. 1253-1258
    • Hillmen, P.1    Lewis, S.M.2    Bessler, M.3
  • 3
    • 16044365965 scopus 로고    scopus 로고
    • Paroxysmal nocturnal haemoglobinuria: long term follow-up and prognostic factors. French Society for Haematology
    • Socie G., Mary J.Y., de Gramont A., et al. Paroxysmal nocturnal haemoglobinuria: long term follow-up and prognostic factors. French Society for Haematology. Lancet 348 (1996) 573-577
    • (1996) Lancet , vol.348 , pp. 573-577
    • Socie, G.1    Mary, J.Y.2    de Gramont, A.3
  • 4
    • 0027310539 scopus 로고
    • Deficiency of the GPI anchor caused by a somatic mutation of the PIG-A gene in paroxysmal nocturnal hemoglobinuria
    • Takeda J., Miyata T., Kawagoe K., et al. Deficiency of the GPI anchor caused by a somatic mutation of the PIG-A gene in paroxysmal nocturnal hemoglobinuria. Cell 73 (1993) 703-711
    • (1993) Cell , vol.73 , pp. 703-711
    • Takeda, J.1    Miyata, T.2    Kawagoe, K.3
  • 5
    • 0028057807 scopus 로고
    • Paroxysmal nocturnal hemoglobinuria (PNH) is caused by somatic mutations in the PIG-A gene
    • Bessler M., Mason P.J., Hillmen P., et al. Paroxysmal nocturnal hemoglobinuria (PNH) is caused by somatic mutations in the PIG-A gene. EMBO-J 13 (1994) 110-117
    • (1994) EMBO-J , vol.13 , pp. 110-117
    • Bessler, M.1    Mason, P.J.2    Hillmen, P.3
  • 6
    • 0036434172 scopus 로고    scopus 로고
    • The glycosylphosphatidylinositol anchor and paroxysmal nocturnal haemoglobinuria/aplasia model
    • Hall C., Richards S.J., and Hillmen P. The glycosylphosphatidylinositol anchor and paroxysmal nocturnal haemoglobinuria/aplasia model. Acta Haematol 108 4 (2002) 219-230
    • (2002) Acta Haematol , vol.108 , Issue.4 , pp. 219-230
    • Hall, C.1    Richards, S.J.2    Hillmen, P.3
  • 7
    • 0032170614 scopus 로고    scopus 로고
    • The spectrum of somatic mutations in the PIG-A gene in paroxysmal nocturnal hemoglobinuria includes large deletions and small duplications
    • Nafa K., Bessler M., Castro-Malaspina H., et al. The spectrum of somatic mutations in the PIG-A gene in paroxysmal nocturnal hemoglobinuria includes large deletions and small duplications. Blood Cells Mol Dis 24 3 (1998) 370-384
    • (1998) Blood Cells Mol Dis , vol.24 , Issue.3 , pp. 370-384
    • Nafa, K.1    Bessler, M.2    Castro-Malaspina, H.3
  • 8
    • 0029981029 scopus 로고    scopus 로고
    • The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria
    • Hall S.E., and Rosse W.F. The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria. Blood 87 (1996) 5332-5340
    • (1996) Blood , vol.87 , pp. 5332-5340
    • Hall, S.E.1    Rosse, W.F.2
  • 9
    • 0033836378 scopus 로고    scopus 로고
    • The application of flow cytometry to the diagnosis of paroxysmal nocturnal hemoglobinuria
    • Richards S.J., Rawstron A.C., and Hillmen P. The application of flow cytometry to the diagnosis of paroxysmal nocturnal hemoglobinuria. Cytometry 42 4 (2000) 223-233
    • (2000) Cytometry , vol.42 , Issue.4 , pp. 223-233
    • Richards, S.J.1    Rawstron, A.C.2    Hillmen, P.3
  • 10
    • 0142084428 scopus 로고    scopus 로고
    • Advances in the laboratory diagnosis of paroxysmal nocturnal hemoglobinuria
    • Richards S.J., and Hillmen P. Advances in the laboratory diagnosis of paroxysmal nocturnal hemoglobinuria. Clin Appl Immunol Rev 1 6 (2001) 315-330
    • (2001) Clin Appl Immunol Rev , vol.1 , Issue.6 , pp. 315-330
    • Richards, S.J.1    Hillmen, P.2
  • 11
    • 0025202564 scopus 로고
    • Deficiency of glycosyl-phosphatidylinositol-linked membrane glycoproteins of leukocytes in paroxysmal nocturnal hemoglobinuria, description of a new diagnostic cytofluorometric assay
    • van der Schoot C.E., Huizinga T.W., van't Veer-Korthof E.T., et al. Deficiency of glycosyl-phosphatidylinositol-linked membrane glycoproteins of leukocytes in paroxysmal nocturnal hemoglobinuria, description of a new diagnostic cytofluorometric assay. Blood 76 (1990) 1853-1859
    • (1990) Blood , vol.76 , pp. 1853-1859
    • van der Schoot, C.E.1    Huizinga, T.W.2    van't Veer-Korthof, E.T.3
  • 12
    • 0030047751 scopus 로고    scopus 로고
    • Expression of glycosyl-phosphotidylinositol-linked glycoproteins in blood cells from paroxysmal nocturnal hemoglobinuria patients. A flow cytometry study using CD55, CD58 and CD59 monoclonal antibodies
    • Navenot J.M., Bernard D., Harousseau J.L., et al. Expression of glycosyl-phosphotidylinositol-linked glycoproteins in blood cells from paroxysmal nocturnal hemoglobinuria patients. A flow cytometry study using CD55, CD58 and CD59 monoclonal antibodies. Leuk Lymphoma 21 (1996) 143-151
    • (1996) Leuk Lymphoma , vol.21 , pp. 143-151
    • Navenot, J.M.1    Bernard, D.2    Harousseau, J.L.3
  • 13
    • 0029748586 scopus 로고    scopus 로고
    • Blood cell flow cytometry in paroxysmal nocturnal hemoglobinuria: a tool for measuring the extent of the PNH clone
    • Alfinito F., Del Vecchio L., Rocco S., et al. Blood cell flow cytometry in paroxysmal nocturnal hemoglobinuria: a tool for measuring the extent of the PNH clone. Leukemia 10 (1996) 1326-1330
    • (1996) Leukemia , vol.10 , pp. 1326-1330
    • Alfinito, F.1    Del Vecchio, L.2    Rocco, S.3
  • 14
    • 17444428972 scopus 로고    scopus 로고
    • Acquired haemolytic anaemias
    • Lewis S.M., Bain B.J., and Bates I. (Eds), Harcourt Health Sciences, London, UK
    • Regan F., Newlands M., and Bain B. Acquired haemolytic anaemias. In: Lewis S.M., Bain B.J., and Bates I. (Eds). Dacie & Lewis practical haematology. 9th edition (2001), Harcourt Health Sciences, London, UK 199-229
    • (2001) Dacie & Lewis practical haematology. 9th edition , pp. 199-229
    • Regan, F.1    Newlands, M.2    Bain, B.3
  • 15
    • 28444483571 scopus 로고    scopus 로고
    • Diagnosis and management of paroxysmal nocturnal hemoglobinuria
    • Parker C., Omine M., Richards S., et al. Diagnosis and management of paroxysmal nocturnal hemoglobinuria. Blood 106 12 (2005) 3699-4709
    • (2005) Blood , vol.106 , Issue.12 , pp. 3699-4709
    • Parker, C.1    Omine, M.2    Richards, S.3
  • 16
    • 0026337156 scopus 로고
    • Biochemical studies on red blood cells from a patient with the inab phenotype (decay-accelerating factor deficiency)
    • Reid M.E., Mallinson G., Sim R.B., et al. Biochemical studies on red blood cells from a patient with the inab phenotype (decay-accelerating factor deficiency). Blood 78 (1991) 3291-3297
    • (1991) Blood , vol.78 , pp. 3291-3297
    • Reid, M.E.1    Mallinson, G.2    Sim, R.B.3
  • 17
    • 0025053264 scopus 로고
    • Inherited complete deficiency of 20-kilodalton homologous restriction factor (CD59) as a cause of paroxysmal nocturnal hemoglobinuria
    • Yamashina M., Ueda E., Kinoshita T., et al. Inherited complete deficiency of 20-kilodalton homologous restriction factor (CD59) as a cause of paroxysmal nocturnal hemoglobinuria. N Engl J Med 323 (1990) 1184-1189
    • (1990) N Engl J Med , vol.323 , pp. 1184-1189
    • Yamashina, M.1    Ueda, E.2    Kinoshita, T.3
  • 18
    • 33846218235 scopus 로고    scopus 로고
    • Quantitative analysis of the expression of glycosylphosphatidylinositol-anchored proteins during the maturation of different hematopoietic cell compartments of normal bone marrow
    • Hernandez-Campo P.M., Almeida J., Matarraz S., et al. Quantitative analysis of the expression of glycosylphosphatidylinositol-anchored proteins during the maturation of different hematopoietic cell compartments of normal bone marrow. Cytometry B Clin Cytom 72 1 (2007) 34-42
    • (2007) Cytometry B Clin Cytom , vol.72 , Issue.1 , pp. 34-42
    • Hernandez-Campo, P.M.1    Almeida, J.2    Matarraz, S.3
  • 19
    • 33644898822 scopus 로고    scopus 로고
    • Normal patterns of expression of glycosylphosphatidylinositol-anchored proteins on different subsets of peripheral blood cells: a frame of reference for the diagnosis of paroxysmal nocturnal hemoglobinuria
    • Hernandez-Campo P.M., Almeida J., Sanchez M.L., et al. Normal patterns of expression of glycosylphosphatidylinositol-anchored proteins on different subsets of peripheral blood cells: a frame of reference for the diagnosis of paroxysmal nocturnal hemoglobinuria. Cytometry B Clin Cytom 70 2 (2006) 71-81
    • (2006) Cytometry B Clin Cytom , vol.70 , Issue.2 , pp. 71-81
    • Hernandez-Campo, P.M.1    Almeida, J.2    Sanchez, M.L.3
  • 20
    • 0032170054 scopus 로고    scopus 로고
    • Lymphocyte subset analysis and glycosylphosphatidylinositol phenotype in patients with paroxysmal nocturnal hemoglobinuria
    • Richards S.J., Norfolk D.R., Swirsky D.M., et al. Lymphocyte subset analysis and glycosylphosphatidylinositol phenotype in patients with paroxysmal nocturnal hemoglobinuria. Blood 92 (1998) 1799-1806
    • (1998) Blood , vol.92 , pp. 1799-1806
    • Richards, S.J.1    Norfolk, D.R.2    Swirsky, D.M.3
  • 21
    • 0034670023 scopus 로고    scopus 로고
    • Immunophenotypic analysis of B cells in PNH: insights into the generation of circulating naive and memory B cells
    • Richards S.J., Morgan G.J., and Hillmen P. Immunophenotypic analysis of B cells in PNH: insights into the generation of circulating naive and memory B cells. Blood 96 (2000) 3522-3528
    • (2000) Blood , vol.96 , pp. 3522-3528
    • Richards, S.J.1    Morgan, G.J.2    Hillmen, P.3
  • 22
    • 0028131848 scopus 로고
    • Persistence of affected T lymphocytes in long-term clinical remission in paroxysmal nocturnal hemoglobinuria
    • Nakakuma H., Nagakura S., Kawaguchi T., et al. Persistence of affected T lymphocytes in long-term clinical remission in paroxysmal nocturnal hemoglobinuria. Blood 84 (1994) 3925-3928
    • (1994) Blood , vol.84 , pp. 3925-3928
    • Nakakuma, H.1    Nagakura, S.2    Kawaguchi, T.3
  • 23
    • 0032535723 scopus 로고    scopus 로고
    • Isotype controls in the analysis of lymphocytes and CD34+ stem and progenitor cells by flow cytometry-time to let go!
    • Keeney M., Gratama J.W., Chin-Yee I.H., et al. Isotype controls in the analysis of lymphocytes and CD34+ stem and progenitor cells by flow cytometry-time to let go!. Cytometry 34 6 (1998) 280-283
    • (1998) Cytometry , vol.34 , Issue.6 , pp. 280-283
    • Keeney, M.1    Gratama, J.W.2    Chin-Yee, I.H.3
  • 24
    • 0034502010 scopus 로고    scopus 로고
    • Improved detection and characterization of paroxysmal nocturnal hemoglobinuria using fluorescent aerolysin
    • Brodsky R.A., Mukhina G.L., Li S., et al. Improved detection and characterization of paroxysmal nocturnal hemoglobinuria using fluorescent aerolysin. Am J Clin Pathol 114 3 (2000) 459-466
    • (2000) Am J Clin Pathol , vol.114 , Issue.3 , pp. 459-466
    • Brodsky, R.A.1    Mukhina, G.L.2    Li, S.3
  • 25
    • 34447571206 scopus 로고    scopus 로고
    • Hillmen P, Richards SJ. Flow cytometry in PNH: serial analysis and the prediction of outcome [abstract]. In: Presented at the American Society of Haematology forty-first annual meeting. San Diego (CA): Blood 94(Suppl 1), 1999. p. 412a.
  • 26
    • 34447551946 scopus 로고    scopus 로고
    • Richards SJ, Hillmen P. Immunophenotypic analysis of PNH cells. In: Robinson JP, managing editor. Current protocols in cytometry, vol. 1: John Wiley and Sons Inc.; 2002. p. 6 11.1-16.
  • 27
    • 33750706563 scopus 로고    scopus 로고
    • Differential usefulness of various markers in the flow cytometric detection of paroxysmal nocturnal hemoglobinuria in blood and bone marrow
    • Olteanu H., Karandikar N.J., McKenna R.W., et al. Differential usefulness of various markers in the flow cytometric detection of paroxysmal nocturnal hemoglobinuria in blood and bone marrow. Am J Clin Pathol 126 5 (2006) 781-788
    • (2006) Am J Clin Pathol , vol.126 , Issue.5 , pp. 781-788
    • Olteanu, H.1    Karandikar, N.J.2    McKenna, R.W.3
  • 28
    • 33947264416 scopus 로고    scopus 로고
    • Evolution of GPI-deficient clones predicts clinical course in paroxysmal nocturnal haemoglobinuria
    • [ASH annual meeting abstracts]
    • Richards S.J., Cullen M.J., Dickinson A.J., et al. Evolution of GPI-deficient clones predicts clinical course in paroxysmal nocturnal haemoglobinuria. Blood 104 (2004) 172 [ASH annual meeting abstracts]
    • (2004) Blood , vol.104 , pp. 172
    • Richards, S.J.1    Cullen, M.J.2    Dickinson, A.J.3
  • 29
    • 0242494954 scopus 로고    scopus 로고
    • Primary prophylaxis with warfarin prevents thrombosis in paroxysmal nocturnal hemoglobinuria
    • Hall C., Richards S.J., and Hillmen P. Primary prophylaxis with warfarin prevents thrombosis in paroxysmal nocturnal hemoglobinuria. Blood 102 (2003) 3587-3591
    • (2003) Blood , vol.102 , pp. 3587-3591
    • Hall, C.1    Richards, S.J.2    Hillmen, P.3
  • 30
    • 3042789125 scopus 로고    scopus 로고
    • Natural history of paroxysmal nocturnal hemoglobinuria using modern diagnostic assays
    • Moyo V.M., Mukhina G.L., Garrett E.S., et al. Natural history of paroxysmal nocturnal hemoglobinuria using modern diagnostic assays. Br J Haematol 126 1 (2004) 133-138
    • (2004) Br J Haematol , vol.126 , Issue.1 , pp. 133-138
    • Moyo, V.M.1    Mukhina, G.L.2    Garrett, E.S.3
  • 31
    • 0029797856 scopus 로고    scopus 로고
    • Evaluation of a novel stable whole blood quality control material for lymphocyte subset analysis: results from the UK NEQAS immune monitoring scheme
    • Barnett D., Granger V., Mayr P., et al. Evaluation of a novel stable whole blood quality control material for lymphocyte subset analysis: results from the UK NEQAS immune monitoring scheme. Cytometry (Communications in Clinical Cytometry) 26 (1996) 216-222
    • (1996) Cytometry (Communications in Clinical Cytometry) , vol.26 , pp. 216-222
    • Barnett, D.1    Granger, V.2    Mayr, P.3
  • 32
    • 0031821570 scopus 로고    scopus 로고
    • + stem cell enumeration: experience of the United Kingdom national external quality assessment scheme (UK NEQAS) using a unique stable whole blood preparation
    • + stem cell enumeration: experience of the United Kingdom national external quality assessment scheme (UK NEQAS) using a unique stable whole blood preparation. Br J Haematol 102 (1998) 553-565
    • (1998) Br J Haematol , vol.102 , pp. 553-565
    • Barnett, D.1    Granger, V.2    Storie, I.3
  • 33
    • 0034026944 scopus 로고    scopus 로고
    • Reduction of intra- and inter-laboratory variation in CD34+ stem cell enumeration by the use of stable test material, standard protocols and targeted training
    • Barnett D., Granger V., Kraan J., et al. Reduction of intra- and inter-laboratory variation in CD34+ stem cell enumeration by the use of stable test material, standard protocols and targeted training. Br J Haematol 108 (2000) 784-792
    • (2000) Br J Haematol , vol.108 , pp. 784-792
    • Barnett, D.1    Granger, V.2    Kraan, J.3
  • 34
    • 34447535819 scopus 로고    scopus 로고
    • Quality control of flow cytometry
    • McCarthy D.A., and Macey M.G. (Eds), Cambridge University Press, Cambridge (UK)
    • Barnett D., and Reilly J.T. Quality control of flow cytometry. In: McCarthy D.A., and Macey M.G. (Eds). Cytometric analysis of cell phenotype and function (2001), Cambridge University Press, Cambridge (UK) 74-88
    • (2001) Cytometric analysis of cell phenotype and function , pp. 74-88
    • Barnett, D.1    Reilly, J.T.2
  • 35
    • 34447563201 scopus 로고    scopus 로고
    • Granger V, Whitby L, Richards SJ, et al. Development and evaluation of a stabilized whole blood preparation as a quality control material for screening for paroxysmal nocturnal haemoglobinuria by flow cytometry [abstract 16]. In: Cytometry part B clinical cytometry [CCS annual meeting abstracts]. Cytometry 68B(1): Savannah, 2005. p. 59.
  • 36
    • 10744228553 scopus 로고    scopus 로고
    • Effect of eculizumab on hemolysis and transfusion requirements in patients with paroxysmal nocturnal hemoglobinuria
    • Hillmen P., Hall C., Marsh J.C.W., et al. Effect of eculizumab on hemolysis and transfusion requirements in patients with paroxysmal nocturnal hemoglobinuria. N Engl J Med 350 6 (2004) 552-559
    • (2004) N Engl J Med , vol.350 , Issue.6 , pp. 552-559
    • Hillmen, P.1    Hall, C.2    Marsh, J.C.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.