메뉴 건너뛰기




Volumn 44, Issue 3, 2007, Pages 407-415

Human temporal bones versus mechanical model to evaluate three middle ear transducers

Author keywords

Anatomical model; Hearing aids; Implantable devices; Laser Doppler vibrometry; Middle ear; Mounting parameter; Rehabilitation; Stapes displacement measurement; Temporal bone; Transducer

Indexed keywords

DRIVING ROD TRANSDUCER (DRT); EAR TRANSDUCERS; FLOATING MASS TRANSDUCER (FMT); IMPLANTABLE DEVICES; MECHANICAL MODELS; STAPES DISPLACEMENT MEASUREMENT; TEMPORAL BONES;

EID: 34447551729     PISSN: 07487711     EISSN: 07487711     Source Type: Journal    
DOI: 10.1682/JRRD.2006.09.0114     Document Type: Article
Times cited : (24)

References (26)
  • 1
    • 34447538614 scopus 로고    scopus 로고
    • Lethbridge-Çejku M, Rose D, Vickerie J. Summary health statistics for U.S. adults: National health interview survey, 2004. Hyattsville (MD): U.S. Department of Health and Human Services, Centers for Disease Control, National Center for Health Statistics; 2006.
    • Lethbridge-Çejku M, Rose D, Vickerie J. Summary health statistics for U.S. adults: National health interview survey, 2004. Hyattsville (MD): U.S. Department of Health and Human Services, Centers for Disease Control, National Center for Health Statistics; 2006.
  • 3
    • 0034981089 scopus 로고    scopus 로고
    • Semi-implantable electromagnetic middle ear hearing device for moderate to severe sensorineural hearing loss
    • Hough JV, Dyer RK Jr, Matthews P, Wood MW. Semi-implantable electromagnetic middle ear hearing device for moderate to severe sensorineural hearing loss. Otolaryngol Clin North Am. 2001;34(2):401-16.
    • (2001) Otolaryngol Clin North Am , vol.34 , Issue.2 , pp. 401-416
    • Hough, J.V.1    Dyer Jr, R.K.2    Matthews, P.3    Wood, M.W.4
  • 4
    • 0141693330 scopus 로고    scopus 로고
    • Current status and critical reflections on implantable hearing aids
    • Huttenbrink KB. Current status and critical reflections on implantable hearing aids. Am J Otol. 1999;20(4):409-15.
    • (1999) Am J Otol , vol.20 , Issue.4 , pp. 409-415
    • Huttenbrink, K.B.1
  • 6
    • 34447514576 scopus 로고    scopus 로고
    • Ball GR, Culp JM, Mar C, Dietz T, Salisbury JD, inventors; Symphonix Devices, Inc, assignee. Implantable and external hearing systems having a floating mass transducer. United States patent US 5857958. 1999 Jan 12
    • Ball GR, Culp JM, Mar C, Dietz T, Salisbury JD, inventors; Symphonix Devices, Inc, assignee. Implantable and external hearing systems having a floating mass transducer. United States patent US 5857958. 1999 Jan 12.
  • 7
    • 0031243371 scopus 로고    scopus 로고
    • An implantable piezoelectric hearing aid transducer for inner ear deafness. II: Clinical implant [in German]
    • Leysieffer H, Baumann JW, Muller G, Zenner HP. An implantable piezoelectric hearing aid transducer for inner ear deafness. II: Clinical implant [in German]. HNO. 1997;45(10):801-15.
    • (1997) HNO , vol.45 , Issue.10 , pp. 801-815
    • Leysieffer, H.1    Baumann, J.W.2    Muller, G.3    Zenner, H.P.4
  • 8
    • 0034982055 scopus 로고    scopus 로고
    • Engineering principles applied to implantable otologic devices
    • Ko WH, Zhu WL, Kane M, Maniglia AJ. Engineering principles applied to implantable otologic devices. Otolaryngol Clin North Am. 2001;34(2):299-314.
    • (2001) Otolaryngol Clin North Am , vol.34 , Issue.2 , pp. 299-314
    • Ko, W.H.1    Zhu, W.L.2    Kane, M.3    Maniglia, A.J.4
  • 9
    • 15744368736 scopus 로고    scopus 로고
    • The effects of mass loading the ossicles with a floating mass transducer on middle ear transfer function
    • Needham AJ, Jiang D, Bibas A, Jeronimidis G, O'Connor AF. The effects of mass loading the ossicles with a floating mass transducer on middle ear transfer function. Otol Neurotol. 2005;26(2):218-24.
    • (2005) Otol Neurotol , vol.26 , Issue.2 , pp. 218-224
    • Needham, A.J.1    Jiang, D.2    Bibas, A.3    Jeronimidis, G.4    O'Connor, A.F.5
  • 10
    • 0141789607 scopus 로고    scopus 로고
    • In vivo characterization of piezoelectric transducers for implantable hearing aids
    • Javel E, Grant IL, Kroll K. In vivo characterization of piezoelectric transducers for implantable hearing aids. Otol Neurotol. 2003;24(5):784-95.
    • (2003) Otol Neurotol , vol.24 , Issue.5 , pp. 784-795
    • Javel, E.1    Grant, I.L.2    Kroll, K.3
  • 11
    • 0030686556 scopus 로고    scopus 로고
    • In vivo studies of a piezoelectric implantable hearing aid transducer in the cat [in German]
    • Plinkert PK, Baumann JW, Lenarz T, Keiner S, Leysieffer H, Zenner HP. In vivo studies of a piezoelectric implantable hearing aid transducer in the cat [in German]. HNO. 1997;45(10):828-39.
    • (1997) HNO , vol.45 , Issue.10 , pp. 828-839
    • Plinkert, P.K.1    Baumann, J.W.2    Lenarz, T.3    Keiner, S.4    Leysieffer, H.5    Zenner, H.P.6
  • 12
    • 1642422200 scopus 로고    scopus 로고
    • Audiometric evaluation of an attempt to optimize the fixation of the transducer of a middle-ear implant to the ossicular chain with bone cement
    • Snik A, Cremers C. Audiometric evaluation of an attempt to optimize the fixation of the transducer of a middle-ear implant to the ossicular chain with bone cement. Clin Otolaryngol Allied Sci. 2004;29(1):5-9.
    • (2004) Clin Otolaryngol Allied Sci , vol.29 , Issue.1 , pp. 5-9
    • Snik, A.1    Cremers, C.2
  • 13
    • 0036357493 scopus 로고    scopus 로고
    • Measurement method for the assessment of transmission properties of implantable hearing aids
    • Pt 2:726-27
    • Winter M, Weber BP, Lenarz T. Measurement method for the assessment of transmission properties of implantable hearing aids. Biomed Tech (Berl). 2002;47(Suppl 1 Pt 2):726-27.
    • (2002) Biomed Tech (Berl) , vol.47 , Issue.SUPPL. 1
    • Winter, M.1    Weber, B.P.2    Lenarz, T.3
  • 14
    • 0030979241 scopus 로고    scopus 로고
    • Gan RZ, Wood MW, Ball GR, Dietz TG, Dormer KJ. Implantable hearing device performance measured by laser Doppler interferometry. Ear Nose Throat J. 1997;76(5): 297-99,302,305-9.
    • Gan RZ, Wood MW, Ball GR, Dietz TG, Dormer KJ. Implantable hearing device performance measured by laser Doppler interferometry. Ear Nose Throat J. 1997;76(5): 297-99,302,305-9.
  • 16
    • 0030679681 scopus 로고    scopus 로고
    • Principle requirements for an electromechanical transducer for implantable hearing aids in inner ear hearing loss. I: Technical and audiologic aspects [in German]
    • Leysieffer H. Principle requirements for an electromechanical transducer for implantable hearing aids in inner ear hearing loss. I: Technical and audiologic aspects [in German]. HNO. 1997;45(10):775-86.
    • (1997) HNO , vol.45 , Issue.10 , pp. 775-786
    • Leysieffer, H.1
  • 17
    • 0012920699 scopus 로고    scopus 로고
    • Measurements of tympanic membrane vibrations in 99 human ears
    • KB Huttenbrink, editor, Sep 19-22; Dresden, Germany. Dresden Germany, Bibliothek der HNO-Universitatsklinik;
    • Nishihara S, Goode R. Measurements of tympanic membrane vibrations in 99 human ears. In: KB Huttenbrink, editor. Proceedings of the International Workshop on Middle Ear Mechanics in Research and Otosurgery; 1996 Sep 19-22; Dresden, Germany. Dresden (Germany): Bibliothek der HNO-Universitatsklinik; 1997. p. 91-95.
    • (1996) Proceedings of the International Workshop on Middle Ear Mechanics in Research and Otosurgery , pp. 91-95
    • Nishihara, S.1    Goode, R.2
  • 18
    • 0032955399 scopus 로고    scopus 로고
    • A human temporal bone study of stapes footplate movement
    • Heiland KE, Goode RL, Asai M, Huber AM. A human temporal bone study of stapes footplate movement. Am J Otol. 1999;20(1):81-86.
    • (1999) Am J Otol , vol.20 , Issue.1 , pp. 81-86
    • Heiland, K.E.1    Goode, R.L.2    Asai, M.3    Huber, A.M.4
  • 20
    • 0030836583 scopus 로고    scopus 로고
    • First comparisons with laser vibrometry measurements and computer simulation of ear ossicle movements [in German]
    • Eiber A, Kauf A, Maassen MM, Burkhardt C, Rodriguez J, Zenner HP. First comparisons with laser vibrometry measurements and computer simulation of ear ossicle movements [in German]. HNO. 1997;45(7):538-44.
    • (1997) HNO , vol.45 , Issue.7 , pp. 538-544
    • Eiber, A.1    Kauf, A.2    Maassen, M.M.3    Burkhardt, C.4    Rodriguez, J.5    Zenner, H.P.6
  • 22
  • 23
    • 0036165804 scopus 로고    scopus 로고
    • Factors contributing to bone conduction: The middle ear
    • Stenfelt S, Hato N, Goode RL. Factors contributing to bone conduction: The middle ear. J Acoust Soc Am. 2002;111(2): 947-59.
    • (2002) J Acoust Soc Am , vol.111 , Issue.2 , pp. 947-959
    • Stenfelt, S.1    Hato, N.2    Goode, R.L.3
  • 24
    • 0022838134 scopus 로고
    • Studies on the mechanics of the reconstructed human middle ear
    • Vlaming MS, Feenstra L. Studies on the mechanics of the reconstructed human middle ear. Clin Otolaryngol Allied Sci. 1986;11(6):411-22.
    • (1986) Clin Otolaryngol Allied Sci , vol.11 , Issue.6 , pp. 411-422
    • Vlaming, M.S.1    Feenstra, L.2
  • 25
    • 33749240766 scopus 로고    scopus 로고
    • Anatomical study of the human middle ear for the design of implantable hearing aids
    • Stieger C, Djeric D, Kompis M, Remonda L, Hausler R. Anatomical study of the human middle ear for the design of implantable hearing aids. Auris Nasus Larynx. 2006;33(4): 375-80.
    • (2006) Auris Nasus Larynx , vol.33 , Issue.4 , pp. 375-380
    • Stieger, C.1    Djeric, D.2    Kompis, M.3    Remonda, L.4    Hausler, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.