메뉴 건너뛰기




Volumn 40, Issue 11, 2007, Pages 2367-2376

Stress-controlled viscoelastic tensile response of bovine cornea

Author keywords

Bovine cornea; Mechanical behavior; Tension; Viscoelasticity

Indexed keywords

BOVINE CORNEAS; LINEAR FRAMEWORK; PHYSIOLOGICAL LOADING; VISCOELASTIC MODEL; VISCOELASTIC TENSILE RESPONSE;

EID: 34447512625     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2006.12.001     Document Type: Article
Times cited : (127)

References (36)
  • 1
    • 0019128538 scopus 로고
    • Biomechanical properties of keratoconus and normal corneas
    • Andreassen T.T., Simonsen A.H., and Oxlund H. Biomechanical properties of keratoconus and normal corneas. Experimental Eye Research 31 4 (1980) 435-441
    • (1980) Experimental Eye Research , vol.31 , Issue.4 , pp. 435-441
    • Andreassen, T.T.1    Simonsen, A.H.2    Oxlund, H.3
  • 2
    • 0037562793 scopus 로고    scopus 로고
    • Collagen fibrils appear more closely packed in the prepupillary cornea: optical and biomechanical implications
    • Boote C., Dennis S., Newton R., Puri H., and Meek K.M. Collagen fibrils appear more closely packed in the prepupillary cornea: optical and biomechanical implications. Investigative Ophthalmology & Visual Science 44 (2003) 2941-2948
    • (2003) Investigative Ophthalmology & Visual Science , vol.44 , pp. 2941-2948
    • Boote, C.1    Dennis, S.2    Newton, R.3    Puri, H.4    Meek, K.M.5
  • 7
    • 2942530700 scopus 로고    scopus 로고
    • The effect of strain rate on the viscoelastic response of aortic valve tissue: a direct-fit approach
    • Doehring T.C., Carew E.O., and Vesely I. The effect of strain rate on the viscoelastic response of aortic valve tissue: a direct-fit approach. Annals of Biomedical Engineering 32 2 (2004) 223-232
    • (2004) Annals of Biomedical Engineering , vol.32 , Issue.2 , pp. 223-232
    • Doehring, T.C.1    Carew, E.O.2    Vesely, I.3
  • 9
    • 33747041981 scopus 로고    scopus 로고
    • Comparative study of corneal strip extensometry and inflation tests
    • Elsheikh A., and Anderson K. Comparative study of corneal strip extensometry and inflation tests. Journal of the Royal Society Interface 2 3 (2005) 177-185
    • (2005) Journal of the Royal Society Interface , vol.2 , Issue.3 , pp. 177-185
    • Elsheikh, A.1    Anderson, K.2
  • 12
    • 0030199985 scopus 로고    scopus 로고
    • Regional elastic performance of the human cornea
    • Hjortdal J.O. Regional elastic performance of the human cornea. Journal of Biomechanics 29 7 (1996) 931-942
    • (1996) Journal of Biomechanics , vol.29 , Issue.7 , pp. 931-942
    • Hjortdal, J.O.1
  • 14
    • 34447578230 scopus 로고    scopus 로고
    • Hukins, D.W.L., 1984. Collagen orientation. In: Hukins, D.W.L. (Ed.), The Connective Tissue Matrix, vol. 5. Macmillan, London, pp. 212-240.
  • 15
    • 34447578229 scopus 로고
    • The mechanical properties of the rabbit and human cornea
    • Jue W., and Maurice D.M. The mechanical properties of the rabbit and human cornea. Journal of Biomechanics 24 (1991) 907-922
    • (1991) Journal of Biomechanics , vol.24 , pp. 907-922
    • Jue, W.1    Maurice, D.M.2
  • 16
    • 0034114509 scopus 로고    scopus 로고
    • Thermal and biomechanical parameters of porcine cornea
    • Kampmeier J., Radt B., Birngruber R., and Brinkmann R. Thermal and biomechanical parameters of porcine cornea. Cornea 19 3 (2000) 355-363
    • (2000) Cornea , vol.19 , Issue.3 , pp. 355-363
    • Kampmeier, J.1    Radt, B.2    Birngruber, R.3    Brinkmann, R.4
  • 18
    • 70449138788 scopus 로고
    • The structure and transparency of the cornea
    • Maurice D.M. The structure and transparency of the cornea. Journal of Physiology 136 (1957) 263-286
    • (1957) Journal of Physiology , vol.136 , pp. 263-286
    • Maurice, D.M.1
  • 19
    • 0023234536 scopus 로고
    • The organization of collagen fibrils in the human corneal stroma: a synchrotron X-ray diffraction study
    • Meek K.M., Blamires T., Elliott G.F., Gyi T.J., and Nave C. The organization of collagen fibrils in the human corneal stroma: a synchrotron X-ray diffraction study. Current Eye Research 6 (1987) 841-846
    • (1987) Current Eye Research , vol.6 , pp. 841-846
    • Meek, K.M.1    Blamires, T.2    Elliott, G.F.3    Gyi, T.J.4    Nave, C.5
  • 20
    • 0001486815 scopus 로고
    • A simple model representing internal damping in solid materials
    • Neubert H.K.P. A simple model representing internal damping in solid materials. Aeronautical Quarterly 14 2 (1963) 187-210
    • (1963) Aeronautical Quarterly , vol.14 , Issue.2 , pp. 187-210
    • Neubert, H.K.P.1
  • 21
    • 34447571215 scopus 로고    scopus 로고
    • Nguyen, T.D., Boyce, B.L., Jones, R.E., 2007. A nonlinear viscoelastic model for the tensile behavior of bovine cornea. Journal of Biomechanics, submitted for publication.
  • 22
    • 0014271269 scopus 로고
    • Rheology of the cornea: experimental techniques and results
    • Nyquist G.W. Rheology of the cornea: experimental techniques and results. Experimental Eye Research 7 (1968) 183-188
    • (1968) Experimental Eye Research , vol.7 , pp. 183-188
    • Nyquist, G.W.1
  • 23
    • 0025785926 scopus 로고
    • A microstructurally-based finite element model of the incised human cornea
    • Pinsky P.M., and Datye D.V. A microstructurally-based finite element model of the incised human cornea. Journal of Biomechanics 24 (1991) 907-922
    • (1991) Journal of Biomechanics , vol.24 , pp. 907-922
    • Pinsky, P.M.1    Datye, D.V.2
  • 25
    • 0031712479 scopus 로고    scopus 로고
    • Viscoelastic constitutive law in large deformations: application to human knee ligaments and tendons
    • Pioletti D.P., Rakotomanana L.R., Benvenuti J.-F., and Leyvraz P.-F. Viscoelastic constitutive law in large deformations: application to human knee ligaments and tendons. Journal of Biomechanics 31 (1998) 753-757
    • (1998) Journal of Biomechanics , vol.31 , pp. 753-757
    • Pioletti, D.P.1    Rakotomanana, L.R.2    Benvenuti, J.-F.3    Leyvraz, P.-F.4
  • 31
    • 0036182656 scopus 로고    scopus 로고
    • Time-dependent mechanical behavior of sheep digital tendons, including the effects of preconditioning
    • Sverdlik A., and Lanir Y. Time-dependent mechanical behavior of sheep digital tendons, including the effects of preconditioning. Transactions of the ASME, Journal of Biomechanical Engineering 124 1 (2002) 78-84
    • (2002) Transactions of the ASME, Journal of Biomechanical Engineering , vol.124 , Issue.1 , pp. 78-84
    • Sverdlik, A.1    Lanir, Y.2
  • 32
    • 0014698583 scopus 로고
    • Mechanical characterization of skin-finite deformation
    • Veronda D.R., and Westmann R. Mechanical characterization of skin-finite deformation. Journal of Biomechanics 3 (1970) 11-124
    • (1970) Journal of Biomechanics , vol.3 , pp. 11-124
    • Veronda, D.R.1    Westmann, R.2
  • 33
    • 0036273181 scopus 로고    scopus 로고
    • Ligament material behavior is nonlinear, viscoelastic and rate-independent under shear loading
    • Weiss J.A., Gardiner J.C., and Bonifasi-Lista C. Ligament material behavior is nonlinear, viscoelastic and rate-independent under shear loading. Journal of Biomechanics 35 (2002) 943-950
    • (2002) Journal of Biomechanics , vol.35 , pp. 943-950
    • Weiss, J.A.1    Gardiner, J.C.2    Bonifasi-Lista, C.3
  • 34
    • 0141707873 scopus 로고    scopus 로고
    • Stress-strain measurements of human and porcine corneas after riboflavin-ultraviolet-a induced cross-linking
    • Wollensak G., Spoerl E., and Seiler T. Stress-strain measurements of human and porcine corneas after riboflavin-ultraviolet-a induced cross-linking. Journal of Cataract and Refractive Surgery 29 9 (2003) 1780-1785
    • (2003) Journal of Cataract and Refractive Surgery , vol.29 , Issue.9 , pp. 1780-1785
    • Wollensak, G.1    Spoerl, E.2    Seiler, T.3
  • 36
    • 0035099812 scopus 로고    scopus 로고
    • A comparison of biomechanical properties between human and porcine cornea
    • Zeng Y.J., Yang J., Huang K., Lee Z.H., and Lee X.Y. A comparison of biomechanical properties between human and porcine cornea. Journal of Biomechanics 34 (2001) 533-537
    • (2001) Journal of Biomechanics , vol.34 , pp. 533-537
    • Zeng, Y.J.1    Yang, J.2    Huang, K.3    Lee, Z.H.4    Lee, X.Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.