메뉴 건너뛰기




Volumn 84, Issue 2, 2007, Pages 690-692

Off-Pump Coronary Artery Bypass Graft Surgery With a Pulsatile Catheter Pump for Left Ventricular Dysfunction

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA BALLOON; ARTICLE; CLINICAL ARTICLE; DISPOSABLE EQUIPMENT; FEMALE; HEART ASSIST DEVICE; HEART LEFT VENTRICLE FAILURE; HEMODYNAMICS; HUMAN; MALE; MORTALITY; OFF PUMP CORONARY SURGERY; PRIORITY JOURNAL; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 34447504772     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2006.12.016     Document Type: Article
Times cited : (11)

References (8)
  • 1
    • 85129765887 scopus 로고    scopus 로고
    • Off-pump versus conventional coronary artery bypass grafting: a meta-analysis and consensus statement from the 2004 IMICS consensus conference
    • Puskas J., Cheng D., Knight J., et al. Off-pump versus conventional coronary artery bypass grafting: a meta-analysis and consensus statement from the 2004 IMICS consensus conference. Innovations 1 (2005) 3-27
    • (2005) Innovations , vol.1 , pp. 3-27
    • Puskas, J.1    Cheng, D.2    Knight, J.3
  • 2
    • 1342326310 scopus 로고    scopus 로고
    • Avoidance of cardiopulmonary bypass improves early survival in multivessel coronary artery bypass patients with poor ventricular function
    • Dewey T.M., Herbert M.A., Prince S.L., et al. Avoidance of cardiopulmonary bypass improves early survival in multivessel coronary artery bypass patients with poor ventricular function. Heart Surg Forum 7 (2004) 45-50
    • (2004) Heart Surg Forum , vol.7 , pp. 45-50
    • Dewey, T.M.1    Herbert, M.A.2    Prince, S.L.3
  • 3
    • 0033391073 scopus 로고    scopus 로고
    • Evaluation of the optimal driving mode during left ventricular assist with a pulsatile catheter pump in calves
    • Mihaylov D., Verkerke G.J., Blanksma P.K., Elstrodt J., de Jong E.D., and Rakhorst G. Evaluation of the optimal driving mode during left ventricular assist with a pulsatile catheter pump in calves. Artif Organs 23 (1999) 1117-1122
    • (1999) Artif Organs , vol.23 , pp. 1117-1122
    • Mihaylov, D.1    Verkerke, G.J.2    Blanksma, P.K.3    Elstrodt, J.4    de Jong, E.D.5    Rakhorst, G.6
  • 4
    • 0033768943 scopus 로고    scopus 로고
    • In vivo and in vitro experience with the PUCA-II, a single valved pulsatile catheter pump
    • Mihaylov D., Rakhorst G., van der Plaats A., et al. In vivo and in vitro experience with the PUCA-II, a single valved pulsatile catheter pump. Int J Artif Organs 23 (2000) 697-702
    • (2000) Int J Artif Organs , vol.23 , pp. 697-702
    • Mihaylov, D.1    Rakhorst, G.2    van der Plaats, A.3
  • 6
    • 0032728973 scopus 로고    scopus 로고
    • Numerical simulation of the pulsating catheter pump: a left ventricular assist device
    • Verkerke G.J., Mihaylov D., Geertsema A.A.J., and Rakhorst G. Numerical simulation of the pulsating catheter pump: a left ventricular assist device. Artif Organs 23 (1999) 924-931
    • (1999) Artif Organs , vol.23 , pp. 924-931
    • Verkerke, G.J.1    Mihaylov, D.2    Geertsema, A.A.J.3    Rakhorst, G.4
  • 8
    • 19644363375 scopus 로고    scopus 로고
    • Total arterial off-pump coronary surgery: time to change our habits?
    • Mariani M.A., D'Alfonso A., and Grandjean J.G. Total arterial off-pump coronary surgery: time to change our habits?. Ann Thorac Surg 78 (2005) 1591-1597
    • (2005) Ann Thorac Surg , vol.78 , pp. 1591-1597
    • Mariani, M.A.1    D'Alfonso, A.2    Grandjean, J.G.3