메뉴 건너뛰기




Volumn 23, Issue 10, 1999, Pages 924-931

Numerical simulation of the pulsating catheter pump: A left ventricular assist device

Author keywords

Left ventricular assist device; Mechanical circulatory support system; Numerical simulation

Indexed keywords

BLOOD; BLOOD VESSELS; FIBER OPTIC SENSORS; LEFT VENTRICULAR ASSIST DEVICES; NUMERICAL MODELS; PUMPS;

EID: 0032728973     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1594.1999.06249.x     Document Type: Article
Times cited : (13)

References (18)
  • 3
    • 0009500838 scopus 로고    scopus 로고
    • Design and testing of a catheter pump to assist the left ventricular device
    • Steenbrink J, Wijers-Hille MJ, de Jong DS, eds. Utrecht: KT Verlag GmbH, ISSN 0937-1753
    • 3. Verkerke GJ, Rakhorst G, Linnewiel R. Design and testing of a catheter pump to assist the left ventricular device. In: Steenbrink J, Wijers-Hille MJ, de Jong DS, eds. Fourth European Congress on Extra-corporeal circulation technology. Utrecht: KT Verlag GmbH, 1996:89-94 (ISSN 0937-1753).
    • (1996) Fourth European Congress on Extra-corporeal Circulation Technology , pp. 89-94
    • Verkerke, G.J.1    Rakhorst, G.2    Linnewiel, R.3
  • 7
    • 0025796598 scopus 로고
    • Current techniques to improve the blood compatibility of biomaterial surfaces
    • 7. Engbers GHM, Feijen J. Current techniques to improve the blood compatibility of biomaterial surfaces. Int J Artif Organs 1991;14:199-215.
    • (1991) Int J Artif Organs , vol.14 , pp. 199-215
    • Engbers, G.H.M.1    Feijen, J.2
  • 9
    • 0022214273 scopus 로고
    • Platelet and coagulation parameters following millisecond exposure to laminar shear stress
    • 9. Wurzinger LJ, Opitz R, Blasberg P, Schmid-Schönbein H. Platelet and coagulation parameters following millisecond exposure to laminar shear stress. Thromb Haemost 1985;54: 381-6.
    • (1985) Thromb Haemost , vol.54 , pp. 381-386
    • Wurzinger, L.J.1    Opitz, R.2    Blasberg, P.3    Schmid-Schönbein, H.4
  • 11
    • 0000422791 scopus 로고
    • Some mechanical effects that influence hemolysis
    • 11. Blackshear PL, Dorman FD, Steinbach JS. Some mechanical effects that influence hemolysis. ASAIO 1965;11:112-7.
    • (1965) ASAIO , vol.11 , pp. 112-117
    • Blackshear, P.L.1    Dorman, F.D.2    Steinbach, J.S.3
  • 12
    • 0030740053 scopus 로고    scopus 로고
    • The importance of pulsatile and nonpulsatile flow in the design of blood pumps
    • 12. Allen GS, Murray KD Olsen DB. The importance of pulsatile and nonpulsatile flow in the design of blood pumps. Artif Organs 1997;21(8):922-8.
    • (1997) Artif Organs , vol.21 , Issue.8 , pp. 922-928
    • Allen, G.S.1    Murray, K.D.2    Olsen, D.B.3
  • 13
    • 0028604410 scopus 로고
    • Evaluation of pulsatile and nonpulsatile flow in cappilaries of goat skeletal muscle using intravital microscopy
    • 13. Lee JJ, Tyml K, Menkis AH, Novick RJ, McKenzie FN, Evaluation of pulsatile and nonpulsatile flow in cappilaries of goat skeletal muscle using intravital microscopy. Microvasc Res 1994;48(3):316-27.
    • (1994) Microvasc Res , vol.48 , Issue.3 , pp. 316-327
    • Lee, J.J.1    Tyml, K.2    Menkis, A.H.3    Novick, R.J.4    McKenzie, F.N.5
  • 14
    • 0030020565 scopus 로고    scopus 로고
    • The effect of pulsatile and nonpulsatile perfusion on renal sympathic nerve activity in anaesthetized dogs
    • 14. Fukae K, Tominaga R, Tokunaga S, Kawachi Y, Imaizumi T, Yasui H. The effect of pulsatile and nonpulsatile perfusion on renal sympathic nerve activity in anaesthetized dogs. J Thorac Cardiovasc Surg 1996;11(2):478-84.
    • (1996) J Thorac Cardiovasc Surg , vol.11 , Issue.2 , pp. 478-484
    • Fukae, K.1    Tominaga, R.2    Tokunaga, S.3    Kawachi, Y.4    Imaizumi, T.5    Yasui, H.6
  • 16
    • 0025801818 scopus 로고
    • Cavilation potential of mechanical heart valve prostheses
    • 16. Graf T, Fisher H, Reul H, Rau G. Cavilation potential of mechanical heart valve prostheses. Int J Artif Organs 1991;14: 169-74.
    • (1991) Int J Artif Organs , vol.14 , pp. 169-174
    • Graf, T.1    Fisher, H.2    Reul, H.3    Rau, G.4
  • 18
    • 0030825369 scopus 로고    scopus 로고
    • Numerical modelling of blood flow behaviour in the valved catheter of the PUCA-pump, a LVAD
    • 18. Morsink PLJ, Verkerke GJ, Grootenboer HJ, Rakhorst G. Numerical modelling of blood flow behaviour in the valved catheter of the PUCA-pump, a LVAD. Int J Artif Organs 1997;20(5):277-84.
    • (1997) Int J Artif Organs , vol.20 , Issue.5 , pp. 277-284
    • Morsink, P.L.J.1    Verkerke, G.J.2    Grootenboer, H.J.3    Rakhorst, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.