메뉴 건너뛰기




Volumn 39, Issue 8, 2007, Pages 720-724

Wireless pH monitoring: Better tolerability and lower impact on daily habits

Author keywords

Daily; Food; Gastro oesophageal reflux disease; Wireless pH monitoring

Indexed keywords

ADULT; ARTICLE; CATHETER COMPLICATION; CONTROLLED STUDY; DAILY LIFE ACTIVITY; DIAGNOSTIC ACCURACY; ESOPHAGUS PH; FEMALE; FOOD INTAKE; GASTROESOPHAGEAL REFLUX; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; PATIENT SATISFACTION; QUESTIONNAIRE; TELEMETRY; VISUAL ANALOG SCALE;

EID: 34447294849     PISSN: 15908658     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.dld.2007.05.011     Document Type: Article
Times cited : (23)

References (20)
  • 1
    • 13744261420 scopus 로고    scopus 로고
    • Updated guidelines for diagnisis and treatment of gastroesophageal reflux disease
    • De Vault K., and Castell D. Updated guidelines for diagnisis and treatment of gastroesophageal reflux disease. Am J Gastroenterol 100 (2005) 190-200
    • (2005) Am J Gastroenterol , vol.100 , pp. 190-200
    • De Vault, K.1    Castell, D.2
  • 2
    • 0029980832 scopus 로고    scopus 로고
    • Clinical esophageal pH recording: a technical review for practice guideline development
    • Kahrilas P., and Quingley E. Clinical esophageal pH recording: a technical review for practice guideline development. Gastroenterology 110 (1996) 1982-1996
    • (1996) Gastroenterology , vol.110 , pp. 1982-1996
    • Kahrilas, P.1    Quingley, E.2
  • 3
    • 0032727843 scopus 로고    scopus 로고
    • Effect of ambulatory 24-h esophageal pH monitoring on reflux-provoking activities
    • Fass R., Hell R., Sampliner R., Pulliam G., Graver E., Hartz V., et al. Effect of ambulatory 24-h esophageal pH monitoring on reflux-provoking activities. Dig Dis Sci 44 (1999) 2263-2269
    • (1999) Dig Dis Sci , vol.44 , pp. 2263-2269
    • Fass, R.1    Hell, R.2    Sampliner, R.3    Pulliam, G.4    Graver, E.5    Hartz, V.6
  • 5
    • 13544254482 scopus 로고    scopus 로고
    • Feasibility and tolerability of transnasal/per-oral placement of the wireless pH capsule vs. traditional 24-h oesophageal pH monitoring-a randomized trial
    • Wong W., Bautista J., Dekel R., Malagon I., Tuchinsky I., Green C., et al. Feasibility and tolerability of transnasal/per-oral placement of the wireless pH capsule vs. traditional 24-h oesophageal pH monitoring-a randomized trial. Aliment Pharmacol Ther 21 (2005) 155-163
    • (2005) Aliment Pharmacol Ther , vol.21 , pp. 155-163
    • Wong, W.1    Bautista, J.2    Dekel, R.3    Malagon, I.4    Tuchinsky, I.5    Green, C.6
  • 8
    • 33645814230 scopus 로고    scopus 로고
    • Wireless esophageal pH monitoring new technique means new questions
    • Bhat Y.M.M.K., and Bielefeldt K. Wireless esophageal pH monitoring new technique means new questions. J Clin gastroenterol 40 (2006) 116-121
    • (2006) J Clin gastroenterol , vol.40 , pp. 116-121
    • Bhat, Y.M.M.K.1    Bielefeldt, K.2
  • 9
    • 26044481434 scopus 로고    scopus 로고
    • Tolerance and reliability of wireless pH monitoring in children
    • Hochman J.A.F.-S.J. Tolerance and reliability of wireless pH monitoring in children. J Pediatr Gastroenterol Nutr 41 (2005) 411-415
    • (2005) J Pediatr Gastroenterol Nutr , vol.41 , pp. 411-415
    • Hochman, J.A.F.-S.J.1
  • 10
    • 0036146916 scopus 로고    scopus 로고
    • Effect of calories and fat on postprandial gastro-oesophageal reflux
    • Colombo P., Mangano M., Bianchi P., and Penagini R. Effect of calories and fat on postprandial gastro-oesophageal reflux. Scand J Gastroenterol 37 (2002) 3-5
    • (2002) Scand J Gastroenterol , vol.37 , pp. 3-5
    • Colombo, P.1    Mangano, M.2    Bianchi, P.3    Penagini, R.4
  • 11
    • 0025222695 scopus 로고
    • Esophageal 24-h pH monitoring: is prior manometry necessary for correct positioning of the electrode?
    • Klauser A., Schindlbeck N., and Muller-Lissner S. Esophageal 24-h pH monitoring: is prior manometry necessary for correct positioning of the electrode?. Am J Gastroenterol 85 (1990) 1463-1467
    • (1990) Am J Gastroenterol , vol.85 , pp. 1463-1467
    • Klauser, A.1    Schindlbeck, N.2    Muller-Lissner, S.3
  • 13
    • 0023904450 scopus 로고
    • The symptom index: a clinically important parameter of ambulatory 24-h esophageal pH monitoring
    • Wiener G.J., Richter J.E., Copper J.B., Wu W.C., and Castel D.O. The symptom index: a clinically important parameter of ambulatory 24-h esophageal pH monitoring. Am J Gastroenterol 83 (1988) 358-361
    • (1988) Am J Gastroenterol , vol.83 , pp. 358-361
    • Wiener, G.J.1    Richter, J.E.2    Copper, J.B.3    Wu, W.C.4    Castel, D.O.5
  • 14
    • 27644436941 scopus 로고    scopus 로고
    • Simultaneous recordings of oesophageal acid exposure with conventional pH monitoring and a wireless system (Bravo)
    • Bruley des Varannes S., Mion F., Ducrottè P., Zerbib F., denis P., Ponchon T., et al. Simultaneous recordings of oesophageal acid exposure with conventional pH monitoring and a wireless system (Bravo). Gut 54 (2005) 1682-1686
    • (2005) Gut , vol.54 , pp. 1682-1686
    • Bruley des Varannes, S.1    Mion, F.2    Ducrottè, P.3    Zerbib, F.4    denis, P.5    Ponchon, T.6
  • 15
    • 0023677856 scopus 로고
    • Ambulatory 24-h esophageal pH monitoring. Reproducibility and variability of pH parameters
    • Wiener G.J., Morgan T.M., Copper J.B., Wu W.C., Castell D.O., Sinclair J.W., et al. Ambulatory 24-h esophageal pH monitoring. Reproducibility and variability of pH parameters. Dig Dis Sci 33 (1988) 1127-1133
    • (1988) Dig Dis Sci , vol.33 , pp. 1127-1133
    • Wiener, G.J.1    Morgan, T.M.2    Copper, J.B.3    Wu, W.C.4    Castell, D.O.5    Sinclair, J.W.6
  • 16
    • 16844370817 scopus 로고    scopus 로고
    • Value of extended recording time with wireless pH monitoring in evaluating gastroesophageal reflux disease
    • Prakash C., and Clouse R.E. Value of extended recording time with wireless pH monitoring in evaluating gastroesophageal reflux disease. Clin Gastroenterol Hepatol 3 (2005) 329-334
    • (2005) Clin Gastroenterol Hepatol , vol.3 , pp. 329-334
    • Prakash, C.1    Clouse, R.E.2
  • 17
    • 34447298938 scopus 로고    scopus 로고
    • Catheter-free prolonged oesophageal pH monitoring in patients with symptoms related to acid reflux
    • Pumpo R.M.A., and Marone G. Catheter-free prolonged oesophageal pH monitoring in patients with symptoms related to acid reflux. Dig Liver Dis 38 (2006) S61
    • (2006) Dig Liver Dis , vol.38
    • Pumpo, R.M.A.1    Marone, G.2
  • 18
    • 34447302098 scopus 로고    scopus 로고
    • Evaluation of 96-h pH monitoring with the Bravo wireless system in 60 patients
    • Scarpulla G.G.P., Manganaro M., and Camilleri S. Evaluation of 96-h pH monitoring with the Bravo wireless system in 60 patients. Dig Liver Dis (2006) S11
    • (2006) Dig Liver Dis
    • Scarpulla, G.G.P.1    Manganaro, M.2    Camilleri, S.3
  • 19
    • 22144491540 scopus 로고    scopus 로고
    • Wireless oesophageal pH monitoring: feasibility, safety and normal values in healthy subjects
    • Wenner J., Johnsson F., Johansson J., and Oberg S. Wireless oesophageal pH monitoring: feasibility, safety and normal values in healthy subjects. Scand J Gastroenterol 40 (2005) 768-774
    • (2005) Scand J Gastroenterol , vol.40 , pp. 768-774
    • Wenner, J.1    Johnsson, F.2    Johansson, J.3    Oberg, S.4
  • 20
    • 3142574856 scopus 로고    scopus 로고
    • Wireless pH testing as an adjunct to unsedated transnasal esophagoscopy: the safety and efficacy of transnasal telemetry capsule placement
    • Belafsky P.C.A.K., Castro-Del Rosario L., and Roseman D. Wireless pH testing as an adjunct to unsedated transnasal esophagoscopy: the safety and efficacy of transnasal telemetry capsule placement. Otolaryngol Head Neck Surg 131 (2004) 26-28
    • (2004) Otolaryngol Head Neck Surg , vol.131 , pp. 26-28
    • Belafsky, P.C.A.K.1    Castro-Del Rosario, L.2    Roseman, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.