메뉴 건너뛰기




Volumn 340, Issue 1-2, 2007, Pages 223-229

New analytical techniques to facilitate preformulation screening in propellant systems

Author keywords

Direct inject; HFA; MDI; MDI stability; Metered valves; Preformulation

Indexed keywords

BECLOMETASONE DIPROPIONATE; IMEXON; PROPELLANT;

EID: 34447275493     PISSN: 03785173     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijpharm.2007.03.026     Document Type: Article
Times cited : (3)

References (12)
  • 1
    • 0033894918 scopus 로고    scopus 로고
    • Pharmaceutical transition to non-CFC pressurized metered dose inhalers
    • Cripps A., Riebe M., Schulze M., and Woodhouse R. Pharmaceutical transition to non-CFC pressurized metered dose inhalers. Resp. Med. 94 (2000) S3-S9
    • (2000) Resp. Med. , vol.94
    • Cripps, A.1    Riebe, M.2    Schulze, M.3    Woodhouse, R.4
  • 2
    • 0025743695 scopus 로고
    • Determination of drug solubility in aerosol propellants
    • Dalby R.N., Phillips E.M., and Byron P.R. Determination of drug solubility in aerosol propellants. Pharm. Res. 8 (1991) 1206-1209
    • (1991) Pharm. Res. , vol.8 , pp. 1206-1209
    • Dalby, R.N.1    Phillips, E.M.2    Byron, P.R.3
  • 3
    • 20644466654 scopus 로고    scopus 로고
    • LC-UV method development and validation for the investigational anticancer agent Imexon and identification of its degradation products
    • Den Brok M.W.J., Nuijen B., Hillebrand M.J.X., Lutz C., Opitz H., and Beijnen J.H. LC-UV method development and validation for the investigational anticancer agent Imexon and identification of its degradation products. J. Pharm. Biomed. Anal. 38 (2005) 686-694
    • (2005) J. Pharm. Biomed. Anal. , vol.38 , pp. 686-694
    • Den Brok, M.W.J.1    Nuijen, B.2    Hillebrand, M.J.X.3    Lutz, C.4    Opitz, H.5    Beijnen, J.H.6
  • 4
    • 20344400666 scopus 로고    scopus 로고
    • Pharmaceutical development of a lyophilized dosage form for the investigational anticancer agent Imexon using dimethyl sulfoxide as a solubilizing and stabilizing agent
    • Den Brok M.W.J., Nuijen B., Lutz C., Opitz H., and Beijnen J.H. Pharmaceutical development of a lyophilized dosage form for the investigational anticancer agent Imexon using dimethyl sulfoxide as a solubilizing and stabilizing agent. J. Pharm. Sci. 94 (2005) 1101-1114
    • (2005) J. Pharm. Sci. , vol.94 , pp. 1101-1114
    • Den Brok, M.W.J.1    Nuijen, B.2    Lutz, C.3    Opitz, H.4    Beijnen, J.H.5
  • 5
    • 4844222139 scopus 로고    scopus 로고
    • Novel method for determination of solubility in aerosol propellants
    • Gupta A., and Myrdal P.B. Novel method for determination of solubility in aerosol propellants. J. Pharm. Sci. 93 (2004) 2411-2419
    • (2004) J. Pharm. Sci. , vol.93 , pp. 2411-2419
    • Gupta, A.1    Myrdal, P.B.2
  • 6
    • 1542268941 scopus 로고    scopus 로고
    • On-line high-performance liquid chromatography method for analyte quantitation from pressurized metered dose inhalers
    • Gupta A., and Myrdal P.B. On-line high-performance liquid chromatography method for analyte quantitation from pressurized metered dose inhalers. J. Chromatogr. A 1003 (2004) 101-106
    • (2004) J. Chromatogr. A , vol.1003 , pp. 101-106
    • Gupta, A.1    Myrdal, P.B.2
  • 7
    • 13844253951 scopus 로고    scopus 로고
    • A comparison of two methods to determine the solubility of compounds in aerosol propellants
    • Gupta A., and Myrdal P.B. A comparison of two methods to determine the solubility of compounds in aerosol propellants. Int. J. Pharm. 292 (2005) 201-209
    • (2005) Int. J. Pharm. , vol.292 , pp. 201-209
    • Gupta, A.1    Myrdal, P.B.2
  • 9
    • 34447248977 scopus 로고    scopus 로고
    • Developments in MDI valve technology ensure better patient compliance
    • Olley J. Developments in MDI valve technology ensure better patient compliance. Drug Deliv. Tech. 7 (2007) 48-51
    • (2007) Drug Deliv. Tech. , vol.7 , pp. 48-51
    • Olley, J.1
  • 10
    • 0038433196 scopus 로고    scopus 로고
    • The influence of formulation variables on the performance of alternative propellant-driven metered dose inhalers
    • Smyth H.D.C. The influence of formulation variables on the performance of alternative propellant-driven metered dose inhalers. Adv. Drug Deliv. Rev. 55 (2003) 807-828
    • (2003) Adv. Drug Deliv. Rev. , vol.55 , pp. 807-828
    • Smyth, H.D.C.1
  • 11
    • 33750856241 scopus 로고    scopus 로고
    • A novel apparatus for the determination of solubility in pressurized metered dose inhalers
    • Traini D., Young P.M., Price R., and Rogueda P. A novel apparatus for the determination of solubility in pressurized metered dose inhalers. Drug Dev. Ind. Pharm. 32 (2006) 1159-1163
    • (2006) Drug Dev. Ind. Pharm. , vol.32 , pp. 1159-1163
    • Traini, D.1    Young, P.M.2    Price, R.3    Rogueda, P.4
  • 12
    • 0032763964 scopus 로고    scopus 로고
    • Study of solubility of steroids in hydrofluoroalkane propellants
    • Williams R.O., Rogers T.L., and Jie L. Study of solubility of steroids in hydrofluoroalkane propellants. Drug Dev. Ind. Pharm. 25 (1999) 1227-1234
    • (1999) Drug Dev. Ind. Pharm. , vol.25 , pp. 1227-1234
    • Williams, R.O.1    Rogers, T.L.2    Jie, L.3