메뉴 건너뛰기




Volumn 49, Issue 13, 2004, Pages

Surface dose extrapolation measurements with radiographic film

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION; DENSITY (OPTICAL); DOSIMETRY; EXTRAPOLATION; IONIZATION CHAMBERS; X RAY SPECTROSCOPY; X RAYS;

EID: 3442884321     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/49/13/N03     Document Type: Article
Times cited : (19)

References (10)
  • 1
    • 0030153343 scopus 로고    scopus 로고
    • 6MV x-ray dose in the build up region: Empirical model and the incident angle effect
    • Butson M, Perez M, Mathur J and Metcalfe P 1996 6MV x-ray dose in the build up region: empirical model and the incident angle effect Australas. Phys. Sci. Eng. Med. 19 74-82
    • (1996) Australas. Phys. Sci. Eng. Med. , vol.19 , pp. 74-82
    • Butson, M.1    Perez, M.2    Mathur, J.3    Metcalfe, P.4
  • 3
    • 0033015509 scopus 로고    scopus 로고
    • Extrapolated surface dose measurements with radiochromic film
    • Butson M J, Yu P and Metcalfe P 1999 Extrapolated surface dose measurements with radiochromic film Med. Phys. 26 485-8
    • (1999) Med. Phys. , vol.26 , pp. 485-488
    • Butson, M.J.1    Yu, P.2    Metcalfe, P.3
  • 4
    • 0020137053 scopus 로고
    • A solid water phantom material for radiotherapy x-ray and gamma ray beam ray calculations
    • Constanitinou C, Attix F and Paliwal B 1982 A solid water phantom material for radiotherapy x-ray and gamma ray beam ray calculations Med. Phys. 9 436-41
    • (1982) Med. Phys. , vol.9 , pp. 436-441
    • Constanitinou, C.1    Attix, F.2    Paliwal, B.3
  • 6
    • 0032925069 scopus 로고    scopus 로고
    • Electron contamination and build-up doses in conformal radiotherapy fields
    • Hounsell A R and Wilkinson J M 1999 Electron contamination and build-up doses in conformal radiotherapy fields Phys. Med. Biol. 44 43-55
    • (1999) Phys. Med. Biol. , vol.44 , pp. 43-55
    • Hounsell, A.R.1    Wilkinson, J.M.2
  • 7
    • 0022627473 scopus 로고
    • Electron contamination from photon beam collimators
    • Nilsson B and Brahme A 1986 Electron contamination from photon beam collimators Radiother. Oncol. 5 235-44
    • (1986) Radiother. Oncol. , vol.5 , pp. 235-244
    • Nilsson, B.1    Brahme, A.2
  • 8
    • 0026695986 scopus 로고
    • Design of parallel plate ion chambers for build up measurements in mega voltage photon beams
    • Rawlinson J A 1992 Design of parallel plate ion chambers for build up measurements in mega voltage photon beams Med. Phys. 19 641-8
    • (1992) Med. Phys. , vol.19 , pp. 641-648
    • Rawlinson, J.A.1
  • 9
  • 10
    • 0031883872 scopus 로고    scopus 로고
    • Electron contamination in 8 and 18 MV photon beams
    • Zhu T C and Palta J R 1998 Electron contamination in 8 and 18 MV photon beams Med. Phys. 25 12-9
    • (1998) Med. Phys. , vol.25 , pp. 12-19
    • Zhu, T.C.1    Palta, J.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.