메뉴 건너뛰기




Volumn 44, Issue 1, 1999, Pages 43-55

Electron contamination and build-up doses in conformal radiotherapy fields

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CALCULATION; CONTAMINATION; ELECTRON; PHANTOM; PHOTON; PRIORITY JOURNAL; RADIATION DOSE; RADIATION FIELD; RADIATION SCATTERING; RADIOTHERAPY;

EID: 0032925069     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/44/1/005     Document Type: Article
Times cited : (38)

References (31)
  • 1
    • 0029610690 scopus 로고
    • Changes to dose in the build-up region when using multi-leaf collimators in place of lead blocks supported on an accessory tray
    • Adams E J and Hounsell A R 1995 Changes to dose in the build-up region when using multi-leaf collimators in place of lead blocks supported on an accessory tray Radiother. Oncol. 37 225-9
    • (1995) Radiother. Oncol. , vol.37 , pp. 225-229
    • Adams, E.J.1    Hounsell, A.R.2
  • 2
    • 0027763598 scopus 로고
    • Characteristics of contamination electrons in high energy photon beams
    • Beauvais H, Bridier A and Dutreix A 1993 Characteristics of contamination electrons in high energy photon beams Radiother. Oncol. 29 308-16
    • (1993) Radiother. Oncol. , vol.29 , pp. 308-316
    • Beauvais, H.1    Bridier, A.2    Dutreix, A.3
  • 3
    • 0018656674 scopus 로고
    • max shift with field size in high energy photon beams
    • max shift with field size in high energy photon beams Med. Phys. 6 291-5
    • (1979) Med. Phys. , vol.6 , pp. 291-295
    • Biggs, P.J.1    Ling, C.C.2
  • 4
    • 0020828171 scopus 로고
    • An investigation into the presence of secondary electrons in megavoltage photon beams
    • Biggs P J and Russell M D 1983 An investigation into the presence of secondary electrons in megavoltage photon beams Phys. Med. Biol. 28 1033-43
    • (1983) Phys. Med. Biol. , vol.28 , pp. 1033-1043
    • Biggs, P.J.1    Russell, M.D.2
  • 5
    • 0028934446 scopus 로고
    • Doses near the surface in high-energy x-ray beams
    • Bjärngard B E, Vadash P and Zhu T 1995 Doses near the surface in high-energy x-ray beams Med. Phys. 22 465-8
    • (1995) Med. Phys. , vol.22 , pp. 465-468
    • Bjärngard, B.E.1    Vadash, P.2    Zhu, T.3
  • 6
    • 0030222479 scopus 로고    scopus 로고
    • An analytical representation of equivalent square field size in relation to surface dose
    • Butson M J, Mathur J N and Metcalfe P E 1996a An analytical representation of equivalent square field size in relation to surface dose Australas. Phys. Eng. Sci. Med. 19 194-6
    • (1996) Australas. Phys. Eng. Sci. Med. , vol.19 , pp. 194-196
    • Butson, M.J.1    Mathur, J.N.2    Metcalfe, P.E.3
  • 8
    • 0028129772 scopus 로고
    • A Monte Carlo study of accelerator head scatter
    • Chancy E L, Cullip T J and Gabriel T A 1994 A Monte Carlo study of accelerator head scatter Med. Phys. 21 1383-90
    • (1994) Med. Phys. , vol.21 , pp. 1383-1390
    • Chancy, E.L.1    Cullip, T.J.2    Gabriel, T.A.3
  • 9
    • 0026472120 scopus 로고
    • On the field-size dependence of relative output from a linear accelerator
    • Dunscombe P B and Nieminen J M 1992 On the field-size dependence of relative output from a linear accelerator Med. Phys. 19 1441-4
    • (1992) Med. Phys. , vol.19 , pp. 1441-1444
    • Dunscombe, P.B.1    Nieminen, J.M.2
  • 10
    • 0023217334 scopus 로고
    • The polarity effect for commercially available plane-parallel ionization chambers
    • Gerbi B J and Khan F M 1987 The polarity effect for commercially available plane-parallel ionization chambers Med. Phys. 14 210-15
    • (1987) Med. Phys. , vol.14 , pp. 210-215
    • Gerbi, B.J.1    Khan, F.M.2
  • 11
    • 0025021187 scopus 로고
    • Measurement of dose in the build-up region using fixed-separation plane-parallel ionization chambers
    • _ 1990 Measurement of dose in the build-up region using fixed-separation plane-parallel ionization chambers Med. Phys. 17 17-26
    • (1990) Med. Phys. , vol.17 , pp. 17-26
  • 12
    • 0014835880 scopus 로고
    • The extension of the concept of tissue-air ratios (TAR) to high-energy x-ray beams
    • Holt J G, Laughlin J S and Moroney J P 1970 The extension of the concept of tissue-air ratios (TAR) to high-energy x-ray beams Radiology 96 437-46
    • (1970) Radiology , vol.96 , pp. 437-446
    • Holt, J.G.1    Laughlin, J.S.2    Moroney, J.P.3
  • 13
    • 0031912342 scopus 로고    scopus 로고
    • Monitor chamber backscatter for intensity modulated radiation therapy using multileaf collimators
    • Hounsell A R 1998 Monitor chamber backscatter for intensity modulated radiation therapy using multileaf collimators Phys. Med. Biol. 43 445-54
    • (1998) Phys. Med. Biol. , vol.43 , pp. 445-454
    • Hounsell, A.R.1
  • 14
    • 0024989580 scopus 로고
    • Tissue standard ratios for irregularly shaped radiotherapy fields
    • Hounsell A R and Wilkinson J M 1990 Tissue standard ratios for irregularly shaped radiotherapy fields Br. J. Radiol. 63 629-34
    • (1990) Br. J. Radiol. , vol.63 , pp. 629-634
    • Hounsell, A.R.1    Wilkinson, J.M.2
  • 15
    • 0029773929 scopus 로고    scopus 로고
    • The variation in output of symmetric, asymmetric and irregularly shaped wedged radiotherapy fields
    • _ 1996 The variation in output of symmetric, asymmetric and irregularly shaped wedged radiotherapy fields Phys. Med. Biol. 41 2155-72
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2155-2172
  • 16
    • 0030758971 scopus 로고    scopus 로고
    • Head scatter modelling for irregular field shaping and intensity modulated fields
    • _ 1997 Head scatter modelling for irregular field shaping and intensity modulated fields Phys. Med. Biol. 42 1737-49
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1737-1749
  • 17
    • 0027752810 scopus 로고
    • X-ray sources of medical linear accelerators: Focal and extra-focal radiation
    • Jaffray D A, Battista J J, Fenster A and Munro P 1993 X-ray sources of medical linear accelerators: focal and extra-focal radiation Med. Phys. 20 1417-27
    • (1993) Med. Phys. , vol.20 , pp. 1417-1427
    • Jaffray, D.A.1    Battista, J.J.2    Fenster, A.3    Munro, P.4
  • 18
    • 0025831283 scopus 로고
    • Analytic representation of the backscatter correction factor at the exit of high energy photon beams
    • Kappas K and Rosenwald J C 1991 Analytic representation of the backscatter correction factor at the exit of high energy photon beams Radiother. Oncol. 21 128-34
    • (1991) Radiother. Oncol. , vol.21 , pp. 128-134
    • Kappas, K.1    Rosenwald, J.C.2
  • 19
    • 0022471631 scopus 로고
    • Head scatter data for several linear accelerators (4-18 MV)
    • Kase K R and Svensson G K 1986 Head scatter data for several linear accelerators (4-18 MV) Med. Phys. 13 530-2
    • (1986) Med. Phys. , vol.13 , pp. 530-532
    • Kase, K.R.1    Svensson, G.K.2
  • 21
    • 0031925289 scopus 로고    scopus 로고
    • Investigation and modelling of the surface dose from linear accelerator produced 6 and 10 MV photon beams
    • Lamb A and Blake S 1998 Investigation and modelling of the surface dose from linear accelerator produced 6 and 10 MV photon beams Phys. Med. Biol. 43 1133-46
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1133-1146
    • Lamb, A.1    Blake, S.2
  • 22
    • 0018758746 scopus 로고
    • Improving the buildup and depth-dose characteristics of high energy photon beams by using electron filters
    • Ling C C and Biggs P J 1979 Improving the buildup and depth-dose characteristics of high energy photon beams by using electron filters Med. Phys. 6 296-301
    • (1979) Med. Phys. , vol.6 , pp. 296-301
    • Ling, C.C.1    Biggs, P.J.2
  • 23
    • 0020037703 scopus 로고
    • Magnetic analysis of the radiation components of a 10 MV photon beam
    • Ling C C, Schell M C and Rustgi S N 1982 Magnetic analysis of the radiation components of a 10 MV photon beam Med. Phys. 9 20-6
    • (1982) Med. Phys. , vol.9 , pp. 20-26
    • Ling, C.C.1    Schell, M.C.2    Rustgi, S.N.3
  • 24
    • 0025242385 scopus 로고
    • Determination of build-up region over-response corrections for a Markus-type chamber
    • Mellenberg D E 1990 Determination of build-up region over-response corrections for a Markus-type chamber Med. Phys. 17 1041-4
    • (1990) Med. Phys. , vol.17 , pp. 1041-1044
    • Mellenberg, D.E.1
  • 25
    • 0021849353 scopus 로고
    • Energy and angular distributions of photons from medical linear accelerators
    • Mohan R, Chui C and Lidofsky L 1985 Energy and angular distributions of photons from medical linear accelerators Med. Phys. 12 592-7
    • (1985) Med. Phys. , vol.12 , pp. 592-597
    • Mohan, R.1    Chui, C.2    Lidofsky, L.3
  • 26
    • 0018176837 scopus 로고
    • Electron contamination of a high-energy x-ray beam
    • Padikal T N and Deye J A 1978 Electron contamination of a high-energy x-ray beam Phys. Med. Biol. 23 1086-92
    • (1978) Phys. Med. Biol. , vol.23 , pp. 1086-1092
    • Padikal, T.N.1    Deye, J.A.2
  • 28
    • 0020528005 scopus 로고
    • Contaminant electrons in the build-up region of a 4 MV photon beam
    • Rustgi S N, Gromadzki Z C, Ling C C and Yorke E D 1983 Contaminant electrons in the build-up region of a 4 MV photon beam Phys. Med. Biol. 28 659-65
    • (1983) Phys. Med. Biol. , vol.28 , pp. 659-665
    • Rustgi, S.N.1    Gromadzki, Z.C.2    Ling, C.C.3    Yorke, E.D.4
  • 29
    • 0028818473 scopus 로고
    • Extrafocal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams
    • Sharpe M B, Jaffray D A, Battista J J and Munro P 1995 Extrafocal radiation: a unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams Med. Phys. 22 2065-74
    • (1995) Med. Phys. , vol.22 , pp. 2065-2074
    • Sharpe, M.B.1    Jaffray, D.A.2    Battista, J.J.3    Munro, P.4
  • 30
    • 0025727879 scopus 로고
    • The determination of phantom and collimator scatter components of the output of megavoltage photon beams. Measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantom
    • Van Gasteren J J M, Heukelom S, van Kleffens H J, van der Laarse R, Venselaar J M L and Westermann C F 1991 The determination of phantom and collimator scatter components of the output of megavoltage photon beams. measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantom Radiother. Oncol. 20 250-7
    • (1991) Radiother. Oncol. , vol.20 , pp. 250-257
    • Van Gasteren, J.J.M.1    Heukelom, S.2    Van Kleffens, H.J.3    Van Der Laarse, R.4    Venselaar, J.M.L.5    Westermann, C.F.6
  • 31
    • 0344738684 scopus 로고
    • An extended source model for the calculation of the primary component of a cobalt-60 radiation beam in penumbral regions
    • Houston: AAPM Radiological Physics Center
    • Wilkinson J M, Rawlinson J A and Cunningham J R 1970 An extended source model for the calculation of the primary component of a cobalt-60 radiation beam in penumbral regions Handbook of Dosimetry for Hodgkins' Disease (Houston: AAPM Radiological Physics Center)
    • (1970) Handbook of Dosimetry for Hodgkins' Disease
    • Wilkinson, J.M.1    Rawlinson, J.A.2    Cunningham, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.