메뉴 건너뛰기




Volumn 292, Issue 5, 2007, Pages

Effect of simultaneous intracoronary guidewires on the predictive accuracy of functional parameters of coronary lesion severity

Author keywords

Coronary disease; Hemodynamics; Microcirculation; Pressure; Stenosis

Indexed keywords

ADULT; ARTICLE; CLINICAL DECISION MAKING; CONTROLLED STUDY; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY OBSTRUCTION; DIAGNOSTIC ACCURACY; DISEASE SEVERITY; FALSE POSITIVE RESULT; FEMALE; FLOW RATE; GUIDE WIRE; HEART MUSCLE ISCHEMIA; HEART MUSCLE PERFUSION; HEART SCINTISCANNING; HEMODYNAMICS; HUMAN; MAJOR CLINICAL STUDY; MALE; PREDICTION; PRESSURE GRADIENT; PRIORITY JOURNAL; SENSOR; AGED; CLASSIFICATION; HEART CATHETERIZATION; HOSPITALIZATION; METHODOLOGY; MIDDLE AGED; PATHOPHYSIOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; VASCULAR RESISTANCE;

EID: 34250842529     PISSN: 03636135     EISSN: 15221539     Source Type: Journal    
DOI: 10.1152/ajpheart.01042.2006     Document Type: Article
Times cited : (18)

References (33)
  • 2
    • 0028370672 scopus 로고
    • Estimated mean flow resistance increase during coronary artery catheterization
    • Back LH. Estimated mean flow resistance increase during coronary artery catheterization. J Biomech 27: 169-175, 1994.
    • (1994) J Biomech , vol.27 , pp. 169-175
    • Back, L.H.1
  • 3
    • 0030087668 scopus 로고    scopus 로고
    • Flow rate-pressure drop relation in coronary angioplasty: Catheter obstruction effect
    • Back LH, Kwack EY, Back MR. Flow rate-pressure drop relation in coronary angioplasty: catheter obstruction effect. J Biomech Eng 118: 83-89, 1996.
    • (1996) J Biomech Eng , vol.118 , pp. 83-89
    • Back, L.H.1    Kwack, E.Y.2    Back, M.R.3
  • 4
    • 0344234274 scopus 로고    scopus 로고
    • Effects of diagnostic guidewire catheter presence on translesional hemodynamic measurements across significant coronary artery stenoses
    • Banerjee RK, Back LH, Back MR. Effects of diagnostic guidewire catheter presence on translesional hemodynamic measurements across significant coronary artery stenoses. Biorheology 40: 613-635, 2003.
    • (2003) Biorheology , vol.40 , pp. 613-635
    • Banerjee, R.K.1    Back, L.H.2    Back, M.R.3
  • 5
    • 0035312340 scopus 로고    scopus 로고
    • Fractional flow reserve, absolute and relative coronary blood flow velocity reserve in relation to the results of technetium-99m sestamibi single-photon emission computed tomography in patients with two-vessel coronary artery disease
    • Chamuleau SA, Meuwissen M, van Eck-Smit BL, Koch KT, de Jong A, de Winter RJ, Schotborgh CE, Bax M, Verberne HJ, Tijssen JG, Piek JJ. Fractional flow reserve, absolute and relative coronary blood flow velocity reserve in relation to the results of technetium-99m sestamibi single-photon emission computed tomography in patients with two-vessel coronary artery disease. J Am Coll Cardiol 37: 1316-1322, 2001.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1316-1322
    • Chamuleau, S.A.1    Meuwissen, M.2    van Eck-Smit, B.L.3    Koch, K.T.4    de Jong, A.5    de Winter, R.J.6    Schotborgh, C.E.7    Bax, M.8    Verberne, H.J.9    Tijssen, J.G.10    Piek, J.J.11
  • 6
    • 0344950520 scopus 로고    scopus 로고
    • Intracoronary and intravenous adenosine 5′- triphosphate, adenosine, papaverine, and contrast medium to assess fractional flow reserve in humans
    • De Bruyne B, Pijls NH, Barbato E, Bartunek J, Bech JW, Wijns W, Heyndrickx GR. Intracoronary and intravenous adenosine 5′- triphosphate, adenosine, papaverine, and contrast medium to assess fractional flow reserve in humans. Circulation 107: 1877-1883, 2003.
    • (2003) Circulation , vol.107 , pp. 1877-1883
    • De Bruyne, B.1    Pijls, N.H.2    Barbato, E.3    Bartunek, J.4    Bech, J.W.5    Wijns, W.6    Heyndrickx, G.R.7
  • 7
    • 0027176093 scopus 로고
    • Transstenotic coronary pressure gradient measurement in humans: In vitro and in vivo evaluation of a new pressure monitoring angioplasty guide wire
    • De Bruyne B, Pijls NH, Paulus WJ, Vantrimpont PJ, Sys SU, Heyndrickx GR. Transstenotic coronary pressure gradient measurement in humans: in vitro and in vivo evaluation of a new pressure monitoring angioplasty guide wire. J Am Coll Cardiol 22: 119-126, 1993.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 119-126
    • De Bruyne, B.1    Pijls, N.H.2    Paulus, W.J.3    Vantrimpont, P.J.4    Sys, S.U.5    Heyndrickx, G.R.6
  • 8
    • 0029841529 scopus 로고    scopus 로고
    • Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve
    • De Bruyne B, Bartunek J, Sys SU, Pijls NH, Heyndrickx GR, Wijns W. Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve. Circulation 94: 1842-1849, 1996.
    • (1996) Circulation , vol.94 , pp. 1842-1849
    • De Bruyne, B.1    Bartunek, J.2    Sys, S.U.3    Pijls, N.H.4    Heyndrickx, G.R.5    Wijns, W.6
  • 9
    • 0029896014 scopus 로고    scopus 로고
    • Utilization of translesional hemodynamics: Comparison of pressure and flow methods in stenosis assessment in patients with coronary artery disease
    • Di Mario C, Gil R, de Feyter PJ, Schuurbiers JC, Serruys PW. Utilization of translesional hemodynamics: comparison of pressure and flow methods in stenosis assessment in patients with coronary artery disease. Cathet Cardiovasc Diagn 38: 189-201, 1996.
    • (1996) Cathet Cardiovasc Diagn , vol.38 , pp. 189-201
    • Di Mario, C.1    Gil, R.2    de Feyter, P.J.3    Schuurbiers, J.C.4    Serruys, P.W.5
  • 10
    • 0345435048 scopus 로고    scopus 로고
    • Coronary pseudo-lesions induced in the left anterior descending and right coronary artery by the angioplasty guide-wire
    • Doshi S, Shiu MF. Coronary pseudo-lesions induced in the left anterior descending and right coronary artery by the angioplasty guide-wire. Int J Cardiol 68: 337-342, 1999.
    • (1999) Int J Cardiol , vol.68 , pp. 337-342
    • Doshi, S.1    Shiu, M.F.2
  • 11
    • 0026504959 scopus 로고
    • Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity
    • Doucette JW, Corl PD, Payne HM, Flynn AE, Goto M, Nassi M, Segal J. Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation 85: 1899-1911, 1992.
    • (1992) Circulation , vol.85 , pp. 1899-1911
    • Doucette, J.W.1    Corl, P.D.2    Payne, H.M.3    Flynn, A.E.4    Goto, M.5    Nassi, M.6    Segal, J.7
  • 13
    • 0022353303 scopus 로고
    • Quantification of coronary artery stenosis in vivo
    • Gould KL. Quantification of coronary artery stenosis in vivo. Circ Res 57: 341-353, 1985.
    • (1985) Circ Res , vol.57 , pp. 341-353
    • Gould, K.L.1
  • 14
    • 0018174760 scopus 로고
    • Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation
    • Gould KL. Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation. Circ Res 43: 242-253, 1978.
    • (1978) Circ Res , vol.43 , pp. 242-253
    • Gould, K.L.1
  • 15
    • 0034352160 scopus 로고    scopus 로고
    • Problems of coronary flow reserve
    • Hoffman JI. Problems of coronary flow reserve. Ann Biomed Eng 28: 884-896, 2000.
    • (2000) Ann Biomed Eng , vol.28 , pp. 884-896
    • Hoffman, J.I.1
  • 16
    • 0030884584 scopus 로고    scopus 로고
    • From research to clinical practice: Current role of intracoronary physiologically based decision making in the cardiac catheterization laboratory
    • Kern MJ, De Bruyne B, Pijls NH. From research to clinical practice: current role of intracoronary physiologically based decision making in the cardiac catheterization laboratory. J Am Coll Cardiol 30: 613-620, 1997.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 613-620
    • Kern, M.J.1    De Bruyne, B.2    Pijls, N.H.3
  • 20
    • 0036323414 scopus 로고    scopus 로고
    • Rationale of combined intracoronary pressure and flow velocity measurements
    • Meuwissen M, Siebes M, Spaan JA, Piek JJ. Rationale of combined intracoronary pressure and flow velocity measurements. Z Kardiol 91, Suppl 3: 108-112, 2002.
    • (2002) Z Kardiol , vol.91 , Issue.SUPPL. 3 , pp. 108-112
    • Meuwissen, M.1    Siebes, M.2    Spaan, J.A.3    Piek, J.J.4
  • 22
    • 0028806554 scopus 로고
    • Fractional flow reserve: A useful index to evaluate the influence of an epicardial coronary stenosis on myocardial blood flow
    • Pijls NH, van Gelder B, van der Voort P, Peels K, Bracke FA, Bonnier HJ, el Gamal MI. Fractional flow reserve: a useful index to evaluate the influence of an epicardial coronary stenosis on myocardial blood flow. Circulation 92: 3183-3193, 1995.
    • (1995) Circulation , vol.92 , pp. 3183-3193
    • Pijls, N.H.1    van Gelder, B.2    van der Voort, P.3    Peels, K.4    Bracke, F.A.5    Bonnier, H.J.6    el Gamal, M.I.7
  • 23
    • 0036158508 scopus 로고    scopus 로고
    • Simultaneous intracoronary pressure and Doppler guidewires to assess coronary stenosis: If one is enough, are two too much?
    • Ruiz-Salmeron RJ, Goicolea J, Sanmartin M, Mantilla R, Sterling J, Romeo D. Simultaneous intracoronary pressure and Doppler guidewires to assess coronary stenosis: if one is enough, are two too much? Catheter Cardiovasc Interv 55: 255-259, 2002.
    • (2002) Catheter Cardiovasc Interv , vol.55 , pp. 255-259
    • Ruiz-Salmeron, R.J.1    Goicolea, J.2    Sanmartin, M.3    Mantilla, R.4    Sterling, J.5    Romeo, D.6
  • 24
    • 0035873810 scopus 로고    scopus 로고
    • Paradoxical increase in microvascular resistance during tachycardia downstream from a severe stenosis in patients with coronary artery disease: Reversal by angioplasty
    • Sambuceti G, Marzilli M, Fedele S, Marini C, L'Abbate A. Paradoxical increase in microvascular resistance during tachycardia downstream from a severe stenosis in patients with coronary artery disease: reversal by angioplasty. Circulation 103: 2352-2360, 2001.
    • (2001) Circulation , vol.103 , pp. 2352-2360
    • Sambuceti, G.1    Marzilli, M.2    Fedele, S.3    Marini, C.4    L'Abbate, A.5
  • 27
    • 1242336789 scopus 로고    scopus 로고
    • Single-wire pressure and flow velocity measurement to quantify coronary stenosis hemodynamics and effects of percutaneous interventions
    • Siebes M, Verhoeff BJ, Meuwissen M, de Winter RJ, Spaan JA, Piek JJ. Single-wire pressure and flow velocity measurement to quantify coronary stenosis hemodynamics and effects of percutaneous interventions. Circulation 109: 756-762, 2004.
    • (2004) Circulation , vol.109 , pp. 756-762
    • Siebes, M.1    Verhoeff, B.J.2    Meuwissen, M.3    de Winter, R.J.4    Spaan, J.A.5    Piek, J.J.6
  • 28
    • 32644444549 scopus 로고    scopus 로고
    • Guidewire flow obstruction effect on pressure drop-flow relationship in moderate coronary artery stenosis
    • Sinha Roy AS, Back LH, Banerjee RK. Guidewire flow obstruction effect on pressure drop-flow relationship in moderate coronary artery stenosis. J Biomech 39: 853-864, 2006.
    • (2006) J Biomech , vol.39 , pp. 853-864
    • Sinha Roy, A.S.1    Back, L.H.2    Banerjee, R.K.3
  • 29
    • 21644479506 scopus 로고    scopus 로고
    • Delineating the guide-wire flow obstruction effect in assessment of fractional flow reserve and coronary flow reserve measurements
    • Sinha Roy AS, Banerjee RK, Back LH, Back MR, Khoury S, Millard RW. Delineating the guide-wire flow obstruction effect in assessment of fractional flow reserve and coronary flow reserve measurements. Am J Physiol Heart Circ Physiol 289: H392-H397, 2005.
    • (2005) Am J Physiol Heart Circ Physiol , vol.289
    • Sinha Roy, A.S.1    Banerjee, R.K.2    Back, L.H.3    Back, M.R.4    Khoury, S.5    Millard, R.W.6
  • 30
    • 33644871996 scopus 로고    scopus 로고
    • Physiological basis of clinically used coronary hemodynamic indices
    • Spaan JA, Piek JJ, Hoffman JI, Siebes M. Physiological basis of clinically used coronary hemodynamic indices. Circulation 113: 446-455, 2006.
    • (2006) Circulation , vol.113 , pp. 446-455
    • Spaan, J.A.1    Piek, J.J.2    Hoffman, J.I.3    Siebes, M.4
  • 31
    • 19944429675 scopus 로고    scopus 로고
    • Verhoeff BJ, Siebes M, Meuwissen M, Atasever B, Voskuil M, de Winter RJ, Koch KT, Tijssen JG, Spaan JA, Piek JJ. Influence of percutaneous coronary intervention on coronary microvascular resistance index. Circulation 111: 76-82, 2005.
    • Verhoeff BJ, Siebes M, Meuwissen M, Atasever B, Voskuil M, de Winter RJ, Koch KT, Tijssen JG, Spaan JA, Piek JJ. Influence of percutaneous coronary intervention on coronary microvascular resistance index. Circulation 111: 76-82, 2005.
  • 33


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.