메뉴 건너뛰기




Volumn 35, Issue 7, 2007, Pages 1791-1792

Pulse contour analysis: Fairy tale or new reality?

Author keywords

Arterial pressure waveform; Cardiac output; Experimental hemorrhage

Indexed keywords

ARTERIAL PRESSURE; BLEEDING; CORONARY ARTERY BYPASS GRAFT; CRITICALLY ILL PATIENT; EDITORIAL; HEART HEMODYNAMICS; HEART LEFT VENTRICLE CONTRACTILITY; HEART OUTPUT; HEART STROKE VOLUME; HUMAN; PRIORITY JOURNAL; PULSE PRESSURE; PULSE RATE; RADIAL ARTERY;

EID: 34250796796     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.CCM.0000269351.38762.B9     Document Type: Editorial
Times cited : (11)

References (21)
  • 1
    • 0000961898 scopus 로고
    • An experimental study of blood pressure and of pulse-pressure in man
    • Erlanger J, Hooker DR: An experimental study of blood pressure and of pulse-pressure in man. Johns Hopkins Hosp Rep 1904; 12:145-378
    • (1904) Johns Hopkins Hosp Rep , vol.12 , pp. 145-378
    • Erlanger, J.1    Hooker, D.R.2
  • 2
    • 0032817727 scopus 로고    scopus 로고
    • Comparison of cardiac output assessed by pulsecontour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting
    • Buhre W, Weyland A, Kazmaier S, et al: Comparison of cardiac output assessed by pulsecontour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting. J Cardiothorac Vasc Anesth 1999; 13:437-440
    • (1999) J Cardiothorac Vasc Anesth , vol.13 , pp. 437-440
    • Buhre, W.1    Weyland, A.2    Kazmaier, S.3
  • 3
    • 0042482769 scopus 로고    scopus 로고
    • Continuous cardiac output measurement: Pulse contour analysis vs thermodilution technique in cardiac surgical patients
    • Rodig G, Prasser C, Keyl C, et al: Continuous cardiac output measurement: Pulse contour analysis vs thermodilution technique in cardiac surgical patients. Br J Anaesth 1999; 82:525-530
    • (1999) Br J Anaesth , vol.82 , pp. 525-530
    • Rodig, G.1    Prasser, C.2    Keyl, C.3
  • 4
    • 0036152801 scopus 로고    scopus 로고
    • Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability
    • Godje O, Hoke K, Goetz AE, et al: Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability. Crit Care Med 2002; 30:52-58
    • (2002) Crit Care Med , vol.30 , pp. 52-58
    • Godje, O.1    Hoke, K.2    Goetz, A.E.3
  • 5
    • 0036198399 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique
    • Della Rocca G, Costa MG, Pompei L, et al: Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth 2002; 88:350-356
    • (2002) Br J Anaesth , vol.88 , pp. 350-356
    • Della Rocca, G.1    Costa, M.G.2    Pompei, L.3
  • 6
    • 0034869820 scopus 로고    scopus 로고
    • A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients
    • Jansen JRC, Schreuder JJ, Mulier JP, et al: A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients. Br J Anaesth 2001; 87:212-222
    • (2001) Br J Anaesth , vol.87 , pp. 212-222
    • Jansen, J.R.C.1    Schreuder, J.J.2    Mulier, J.P.3
  • 7
    • 24944534975 scopus 로고    scopus 로고
    • Less invasive determination of cardiac output from the arterial pressure by aortic diameter-calibrated pulse contour
    • de Vaal JB, de Wilde RBP, van den Berg PCM, et al: Less invasive determination of cardiac output from the arterial pressure by aortic diameter-calibrated pulse contour. Br J Anaesth 2005; 95:326-331
    • (2005) Br J Anaesth , vol.95 , pp. 326-331
    • de Vaal, J.B.1    de Wilde, R.B.P.2    van den Berg, P.C.M.3
  • 8
    • 0035057498 scopus 로고    scopus 로고
    • Continuous cardiac output by pulse contour analysis?
    • van Lieshout JJ, Wesseling KH: Continuous cardiac output by pulse contour analysis? Br J Anaesth 2001; 86:467-469
    • (2001) Br J Anaesth , vol.86 , pp. 467-469
    • van Lieshout, J.J.1    Wesseling, K.H.2
  • 9
    • 34250893209 scopus 로고    scopus 로고
    • Continuous cardiac output monitoring via arterial pressure waveform analysis following severe hemorrhagic shock in dogs
    • Cooper ES, Muir WW: Continuous cardiac output monitoring via arterial pressure waveform analysis following severe hemorrhagic shock in dogs. Crit Care Med 2007; 35:1724-1729
    • (2007) Crit Care Med , vol.35 , pp. 1724-1729
    • Cooper, E.S.1    Muir, W.W.2
  • 10
    • 0035064663 scopus 로고    scopus 로고
    • Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb
    • Linton NWF, Linton RAF: Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. Br J Anaesth 2001; 86:486-496
    • (2001) Br J Anaesth , vol.86 , pp. 486-496
    • Linton, N.W.F.1    Linton, R.A.F.2
  • 11
    • 0036799972 scopus 로고    scopus 로고
    • PulseCO: A less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery
    • Hamilton TT, Huber LM, Jessen ME: PulseCO: A less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery. Ann Thorac Surg 2002; 74: S1408-S1412
    • (2002) Ann Thorac Surg , vol.74
    • Hamilton, T.T.1    Huber, L.M.2    Jessen, M.E.3
  • 12
    • 21244503107 scopus 로고    scopus 로고
    • Cardiac output by PulseCO is not interchangeable with thermodilution in patients undergoing OPCAB
    • Yamashita K, Nishiyama T, Yokoyama T, et al: Cardiac output by PulseCO is not interchangeable with thermodilution in patients undergoing OPCAB. Can J Anesth 2005; 52:530-534
    • (2005) Can J Anesth , vol.52 , pp. 530-534
    • Yamashita, K.1    Nishiyama, T.2    Yokoyama, T.3
  • 13
    • 0021347395 scopus 로고
    • Reliability of clinical monitoring to assess blood volume in critically ill patients
    • Shippy CR, Appel PL, Shoemaker WC: Reliability of clinical monitoring to assess blood volume in critically ill patients. Crit Care Med 1984; 12:107-112
    • (1984) Crit Care Med , vol.12 , pp. 107-112
    • Shippy, C.R.1    Appel, P.L.2    Shoemaker, W.C.3
  • 14
    • 0027415523 scopus 로고
    • Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness
    • Wo CC, Shoemaker WC, Appel PL, et al: Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness. Crit Care Med 1993; 21:218-223
    • (1993) Crit Care Med , vol.21 , pp. 218-223
    • Wo, C.C.1    Shoemaker, W.C.2    Appel, P.L.3
  • 15
    • 33846894301 scopus 로고    scopus 로고
    • A pilot assessment of the FloTrac cardiac output monitoring system
    • Opdam HI, Wan L, Bellomo R: A pilot assessment of the FloTrac cardiac output monitoring system. Intensive Care Med 2007; 33:343-349
    • (2007) Intensive Care Med , vol.33 , pp. 343-349
    • Opdam, H.I.1    Wan, L.2    Bellomo, R.3
  • 16
    • 34247551188 scopus 로고    scopus 로고
    • Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements
    • Sander M, Spies CD, Grubitzsch H, et al: Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements. Crit Care 2006; 10:R164
    • (2006) Crit Care , vol.10
    • Sander, M.1    Spies, C.D.2    Grubitzsch, H.3
  • 17
    • 33847753396 scopus 로고    scopus 로고
    • Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: A comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery
    • Mayer J, Boldt J, Schollhorn T, et al: Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: A comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth 2007; 98:176-182
    • (2007) Br J Anaesth , vol.98 , pp. 176-182
    • Mayer, J.1    Boldt, J.2    Schollhorn, T.3
  • 18
    • 33846669409 scopus 로고    scopus 로고
    • Cardiac output determination from the arterial pressure wave: Clinical testing of a novel algorithm that does not require calibration
    • Manecke GR Jr, Auger WR: Cardiac output determination from the arterial pressure wave: Clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth 2007; 21:3-7
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 3-7
    • Manecke Jr, G.R.1    Auger, W.R.2
  • 19
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LAH, Critchley AJH: A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit 1999; 15:85-91
    • (1999) J Clin Monit , vol.15 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, A.J.H.2
  • 21
    • 23044461875 scopus 로고    scopus 로고
    • Changes in arterial pressure during mechanical ventilation
    • Michard F: Changes in arterial pressure during mechanical ventilation. Anesthesiology 2005; 1003:419-428
    • (2005) Anesthesiology , vol.1003 , pp. 419-428
    • Michard, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.