-
1
-
-
0036255447
-
Stapes surgery: how precisely do different prostheses attach to the long process of the incus with different instruments and different surgeons?
-
Kwok P., Fisch U., Strutz J., et al. Stapes surgery: how precisely do different prostheses attach to the long process of the incus with different instruments and different surgeons?. Otol Neurotol 23 (2002) 289-295
-
(2002)
Otol Neurotol
, vol.23
, pp. 289-295
-
-
Kwok, P.1
Fisch, U.2
Strutz, J.3
-
2
-
-
0019406710
-
The loose wire syndrome
-
McGee T.M. The loose wire syndrome. Laryngoscope 91 (1981) 1478-1483
-
(1981)
Laryngoscope
, vol.91
, pp. 1478-1483
-
-
McGee, T.M.1
-
3
-
-
0037622517
-
Biomechanics of stapesplasty: a review
-
discussion 57-9
-
Huttenbrink K.B. Biomechanics of stapesplasty: a review. Otol Neurotol 24 (2003) 548-557 discussion 57-9
-
(2003)
Otol Neurotol
, vol.24
, pp. 548-557
-
-
Huttenbrink, K.B.1
-
4
-
-
0038642097
-
Stapes prosthesis attachment: the effect of crimping on sound transfer in otosclerosis surgery
-
Huber A.M., Ma F., Felix H., et al. Stapes prosthesis attachment: the effect of crimping on sound transfer in otosclerosis surgery. Laryngoscope 113 (2003) 853-858
-
(2003)
Laryngoscope
, vol.113
, pp. 853-858
-
-
Huber, A.M.1
Ma, F.2
Felix, H.3
-
6
-
-
23344449896
-
Shape-memory stapes prosthesis for otosclerosis surgery
-
Knox G.W., and Reitan H. Shape-memory stapes prosthesis for otosclerosis surgery. Laryngoscope 115 (2005) 1340-1346
-
(2005)
Laryngoscope
, vol.115
, pp. 1340-1346
-
-
Knox, G.W.1
Reitan, H.2
-
7
-
-
13444305498
-
Eliminating the limitations of manual crimping in stapes surgery?. A preliminary trial with the shape memory Nitinol stapes piston
-
Rajan G.P., Atlas M.D., Subramaniam K., et al. Eliminating the limitations of manual crimping in stapes surgery?. A preliminary trial with the shape memory Nitinol stapes piston. Laryngoscope 115 (2005) 366-369
-
(2005)
Laryngoscope
, vol.115
, pp. 366-369
-
-
Rajan, G.P.1
Atlas, M.D.2
Subramaniam, K.3
-
8
-
-
12744261216
-
In vivo performance of the Nitinol shape-memory stapes prosthesis during hearing restoration surgery in otosclerosis: a first report
-
Rajan G.P., Eikelboom R.H., Anandacoomaraswamy K.S., et al. In vivo performance of the Nitinol shape-memory stapes prosthesis during hearing restoration surgery in otosclerosis: a first report. J Biomed Mater Res B Appl Biomater 72 (2005) 305-309
-
(2005)
J Biomed Mater Res B Appl Biomater
, vol.72
, pp. 305-309
-
-
Rajan, G.P.1
Eikelboom, R.H.2
Anandacoomaraswamy, K.S.3
-
9
-
-
0029047601
-
Committee on Hearing and Equilibrium guidelines for the evaluation of results of treatment of conductive hearing loss
-
American Academy of Otolaryngology-Head and Neck Surgery foundation
-
American Academy of Otolaryngology-Head and Neck Surgery foundation. Committee on Hearing and Equilibrium guidelines for the evaluation of results of treatment of conductive hearing loss. Otolaryngol Head Neck Surg 113 (1995) 186-187
-
(1995)
Otolaryngol Head Neck Surg
, vol.113
, pp. 186-187
-
-
-
10
-
-
0000898857
-
Fenestration of the oval window
-
Shea Jr. J.J. Fenestration of the oval window. Ann Otol Rhinol Laryngol 67 (1958) 932-951
-
(1958)
Ann Otol Rhinol Laryngol
, vol.67
, pp. 932-951
-
-
Shea Jr., J.J.1
-
11
-
-
0030899466
-
Utilization of nickel-titanium shape memory alloy for stapes prosthesis
-
Kasano F., and Morimitsu T. Utilization of nickel-titanium shape memory alloy for stapes prosthesis. Auris Nasus Larynx 24 (1997) 137-142
-
(1997)
Auris Nasus Larynx
, vol.24
, pp. 137-142
-
-
Kasano, F.1
Morimitsu, T.2
-
12
-
-
0036843346
-
Stapedectomy versus stapedotomy: comparison of results with long-term follow-up
-
House H.P., Hansen M.R., Al Dakhail A.A., et al. Stapedectomy versus stapedotomy: comparison of results with long-term follow-up. Laryngoscope 112 (2002) 2046-2050
-
(2002)
Laryngoscope
, vol.112
, pp. 2046-2050
-
-
House, H.P.1
Hansen, M.R.2
Al Dakhail, A.A.3
-
14
-
-
2642582913
-
Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures
-
Ryhanen J., Niemi E., Serlo W., et al. Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures. J Biomed Mater Res 35 (1997) 451-457
-
(1997)
J Biomed Mater Res
, vol.35
, pp. 451-457
-
-
Ryhanen, J.1
Niemi, E.2
Serlo, W.3
-
15
-
-
0023905659
-
Local intravascular effects of the nitinol wire blood clot filter
-
Prince M.R., Salzman E.W., Schoen F.J., et al. Local intravascular effects of the nitinol wire blood clot filter. Invest Radiol 23 (1988) 294-300
-
(1988)
Invest Radiol
, vol.23
, pp. 294-300
-
-
Prince, M.R.1
Salzman, E.W.2
Schoen, F.J.3
-
16
-
-
0036179018
-
Surface, corrosion and biocompatibility aspects of Nitinol as an implant material
-
Shabalovskaya S.A. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material. Biomed Mater Eng 12 (2002) 69-109
-
(2002)
Biomed Mater Eng
, vol.12
, pp. 69-109
-
-
Shabalovskaya, S.A.1
|