-
2
-
-
31344455712
-
Literature review of current techniques for the insertion of distal screws into intramedullary locking nails
-
Whatling, G. M. and Nokes, L. D. Literature review of current techniques for the insertion of distal screws into intramedullary locking nails. Injury, 2006 37(2), 109-119.
-
(2006)
Injury
, vol.37
, Issue.2
, pp. 109-119
-
-
Whatling, G.M.1
Nokes, L.D.2
-
3
-
-
0345552149
-
A mechanical distal aiming device for distal locking in femoral nails
-
Krettek, C., Konemann, B., Miclau, T., Kolbli, R., Machreich, T., and Tscherne, H. A mechanical distal aiming device for distal locking in femoral nails. Clinical Orthop. and Relat. Res., 1999, (364), 267-275.
-
(1999)
Clinical Orthop. and Relat. Res
, vol.364
, pp. 267-275
-
-
Krettek, C.1
Konemann, B.2
Miclau, T.3
Kolbli, R.4
Machreich, T.5
Tscherne, H.6
-
4
-
-
0034805228
-
A new distal targeting device for closed interlocking nailing
-
Tyropoulos, S. and Garnavos, C. A new distal targeting device for closed interlocking nailing. Injury, 2001, 32(9), 732-735.
-
(2001)
Injury
, vol.32
, Issue.9
, pp. 732-735
-
-
Tyropoulos, S.1
Garnavos, C.2
-
5
-
-
0025739065
-
An image intensifier laser guidance system for the distal locking of an intramedullary nail
-
Goodall, J. D. An image intensifier laser guidance system for the distal locking of an intramedullary nail. Injury, 1991, 22(4), 339.
-
(1991)
Injury
, vol.22
, Issue.4
, pp. 339
-
-
Goodall, J.D.1
-
6
-
-
0031136974
-
Stereo fluoroscopy-assisted distal interlocking of intramedullary nails
-
Ohe, T., Nakamura, K., Matsushita, T., Nishiki, M., Watanabe, N., and Matsumoto, K. Stereo fluoroscopy-assisted distal interlocking of intramedullary nails. J. Orthop. Trauma, 1997, 11(4), 300-303.
-
(1997)
J. Orthop. Trauma
, vol.11
, Issue.4
, pp. 300-303
-
-
Ohe, T.1
Nakamura, K.2
Matsushita, T.3
Nishiki, M.4
Watanabe, N.5
Matsumoto, K.6
-
7
-
-
0032174409
-
Distal centering in locked intra-medullary osteosynthesis of the femur: Use of a magnet-resistant probe
-
Catamo, L., Rotini, R., Rocca, M., Giardino, R., and Fontanesi, G. Distal centering in locked intra-medullary osteosynthesis of the femur: use of a magnet-resistant probe. La Chirurgia Degli Organi Di Movimento, 1998, 83(4), 375-379.
-
(1998)
La Chirurgia Degli Organi Di Movimento
, vol.83
, Issue.4
, pp. 375-379
-
-
Catamo, L.1
Rotini, R.2
Rocca, M.3
Giardino, R.4
Fontanesi, G.5
-
8
-
-
2642701689
-
A new mechanical aiming device for the placement of distal interlocking screws in femoral nails
-
Krettek, C., Konemann, B., Miclau, T., Kolbli, R., Machreich, T., Kromm, A., and Tscherne, H. A new mechanical aiming device for the placement of distal interlocking screws in femoral nails. Arch. Orthop. and Trauma Surg., 1998, 117(3), 147-152.
-
(1998)
Arch. Orthop. and Trauma Surg
, vol.117
, Issue.3
, pp. 147-152
-
-
Krettek, C.1
Konemann, B.2
Miclau, T.3
Kolbli, R.4
Machreich, T.5
Kromm, A.6
Tscherne, H.7
-
9
-
-
0036788370
-
Radiation exposure to surgeon and patient in intramedullary nailing of the lower limb
-
Madan, S. and Blakeway, C. Radiation exposure to surgeon and patient in intramedullary nailing of the lower limb. Injury, 2002, 33(8), 723-727.
-
(2002)
Injury
, vol.33
, Issue.8
, pp. 723-727
-
-
Madan, S.1
Blakeway, C.2
-
10
-
-
0031204509
-
Radiation exposure to the orthopaedic surgical team during fluoroscopy: 'how far away is far enough?
-
Mehlman, C. T. and DiPasquale, T. G. Radiation exposure to the orthopaedic surgical team during fluoroscopy: 'how far away is far enough?' J. Orthop. Trauma, 1997, 11 (6), 392-398.
-
(1997)
J. Orthop. Trauma
, vol.11
, Issue.6
, pp. 392-398
-
-
Mehlman, C.T.1
DiPasquale, T.G.2
-
11
-
-
21244434304
-
Radiation exposure to the hands of the surgeons: Are we underestimating the risk?
-
Hafez, M. A., Smith, R. M., Matthews, S. J. Kalap, G., and Sherman, K. P. Radiation exposure to the hands of the surgeons: are we underestimating the risk? Arch. Orthop. and Trauma Surg., 2005, 125, 330-335.
-
(2005)
Arch. Orthop. and Trauma Surg
, vol.125
, pp. 330-335
-
-
Hafez, M.A.1
Smith, R.M.2
Matthews, S.J.3
Kalap, G.4
Sherman, K.P.5
-
12
-
-
0017763627
-
Ionizing irradiation and the induction of clinically significant disease in the human thyroid gland
-
Maxon, H. R., Thomas, S. R., Saenger, E. L., Buncher, C. R., and Kereiakes, J. G. Ionizing irradiation and the induction of clinically significant disease in the human thyroid gland. Am. J. Med., 1977, 63(6), 967-978.
-
(1977)
Am. J. Med
, vol.63
, Issue.6
, pp. 967-978
-
-
Maxon, H.R.1
Thomas, S.R.2
Saenger, E.L.3
Buncher, C.R.4
Kereiakes, J.G.5
-
13
-
-
0032822724
-
Fluoroscopy as an imaging means for computer assisted surgical navigation
-
Hofstetter, R., Slomczykowski, M., Sati, M., and Nolte, L. P. Fluoroscopy as an imaging means for computer assisted surgical navigation. Comput. Aided Surg., 1999, 4(2), 65-76.
-
(1999)
Comput. Aided Surg
, vol.4
, Issue.2
, pp. 65-76
-
-
Hofstetter, R.1
Slomczykowski, M.2
Sati, M.3
Nolte, L.P.4
-
14
-
-
0035257635
-
Novel computer-assisted fluoroscopy system for intraoperative guidance: Feasibility study for distal locking of femoral nails
-
Slomczykawksi, M. A., Hofstetter, R., Sati, M., Krretek, C., and Nolte, L. P. Novel computer-assisted fluoroscopy system for intraoperative guidance: feasibility study for distal locking of femoral nails. J. Orthop. Trauma, 2001, 15, 122-131.
-
(2001)
J. Orthop. Trauma
, vol.15
, pp. 122-131
-
-
Slomczykawksi, M.A.1
Hofstetter, R.2
Sati, M.3
Krretek, C.4
Nolte, L.P.5
-
15
-
-
0036381419
-
Recovery of distal hole axis in intramedullary nail trajectory planning
-
Zhu, Y., Phillips, R., Griffiths, J. G., Viant, W. J., Mohsen, A. M., and Bielby, M. Recovery of distal hole axis in intramedullary nail trajectory planning. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2002, 216(H5), 323-332.
-
(2002)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.216
, Issue.H5
, pp. 323-332
-
-
Zhu, Y.1
Phillips, R.2
Griffiths, J.G.3
Viant, W.J.4
Mohsen, A.M.5
Bielby, M.6
-
16
-
-
34249858746
-
Computer assisted orthopaedic surgical system for insertion of distal locking screws in intra-medullary nails: A valid and reliable navigation system
-
Malek, S., Phillips, R., Mohsen, A., Vlant, W., Bielby, M., and Sherman, K. Computer assisted orthopaedic surgical system for insertion of distal locking screws in intra-medullary nails: a valid and reliable navigation system. Int. J. Med. Robotics and Comput. Assisted Surg., 2006, 1(4), 34-44.
-
(2006)
Int. J. Med. Robotics and Comput. Assisted Surg
, vol.1
, Issue.4
, pp. 34-44
-
-
Malek, S.1
Phillips, R.2
Mohsen, A.3
Vlant, W.4
Bielby, M.5
Sherman, K.6
-
17
-
-
0037401152
-
Computer assisted orthopaedic and trauma surgery: State of the art and future perspectives
-
Schep, N., Broeders, I., and Van der Werken, C. Computer assisted orthopaedic and trauma surgery: state of the art and future perspectives. Injury, 2003, 34(4), 299-306.
-
(2003)
Injury
, vol.34
, Issue.4
, pp. 299-306
-
-
Schep, N.1
Broeders, I.2
Van der Werken, C.3
-
18
-
-
0029187048
-
Robotic-assisted internal fixation of femoral fractures
-
Bouazza-Marouf, K., Browbank, I., and Hewit, J. R. Robotic-assisted internal fixation of femoral fractures. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1995, 209(H1), 51-58.
-
(1995)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.209
, Issue.H1
, pp. 51-58
-
-
Bouazza-Marouf, K.1
Browbank, I.2
Hewit, J.R.3
-
19
-
-
0030164882
-
Robotic-assisted invasive surgery
-
Bouazza-Marouf, K., Browbank, I., and Hewit, J. R. Robotic-assisted invasive surgery. J. Mechatronics, 1996, 6(4), 381-387.
-
(1996)
J. Mechatronics
, vol.6
, Issue.4
, pp. 381-387
-
-
Bouazza-Marouf, K.1
Browbank, I.2
Hewit, J.R.3
-
20
-
-
34250705860
-
-
Hochrainer, M. J. Repair of femoral shaft fractures. MSc Thesis, supervised by Dr K. Bouazza-Marouf, Loughborough University, 1997.
-
Hochrainer, M. J. Repair of femoral shaft fractures. MSc Thesis, supervised by Dr K. Bouazza-Marouf, Loughborough University, 1997.
-
-
-
-
21
-
-
0033644024
-
Robotic-assisted internal fixation of hip fractures: A fluoroscopy-based intraoperative registration technique
-
Browbank, I., Bouazza-Marouf, K., and Schnabler, J. Robotic-assisted internal fixation of hip fractures: a fluoroscopy-based intraoperative registration technique. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2000, 214(H2), 165-179.
-
(2000)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.214
, Issue.H2
, pp. 165-179
-
-
Browbank, I.1
Bouazza-Marouf, K.2
Schnabler, J.3
|