메뉴 건너뛰기




Volumn 221, Issue 3, 2007, Pages 379-389

Effect of non-spherical bearing geometry on transient elastohydrodynamic lubrication in metal-on-metal hip joint implants

Author keywords

Elipsoidal cup; Equivalent discrete spherical convolution model; Hip joint implant; Metal on metal; Non sphericity; Spherical bearing; Spherical fast Fourier transform; Transient elastohydrodynamic lubrication

Indexed keywords

COMPUTER SIMULATION; ELASTIC DEFORMATION; FAST FOURIER TRANSFORMS; FILM THICKNESS; HIP PROSTHESES; WEAR OF MATERIALS;

EID: 34250613939     PISSN: 13506501     EISSN: None     Source Type: Journal    
DOI: 10.1243/13506501JET249     Document Type: Conference Paper
Times cited : (19)

References (31)
  • 1
    • 0002989262 scopus 로고
    • Forces transmitted by joints in the human body
    • 3J
    • Paul, J. P. Forces transmitted by joints in the human body. Proc. Instn Mech. Engrs, 1966, 181(3J), 8-15.
    • (1966) Proc. Instn Mech. Engrs , vol.181 , pp. 8-15
    • Paul, J.P.1
  • 2
    • 0030859787 scopus 로고    scopus 로고
    • Repeated measures of adult normal walking using a video tracking system
    • Growney, E., Meglan, D., Johson, T., Cahalan, T., and An, K. N. Repeated measures of adult normal walking using a video tracking system. Gait Posture, 1997, 6, 147-162.
    • (1997) Gait Posture , vol.6 , pp. 147-162
    • Growney, E.1    Meglan, D.2    Johson, T.3    Cahalan, T.4    An, K.N.5
  • 3
    • 4744355541 scopus 로고    scopus 로고
    • The role of macrophages in osteolysis of total joint replacement
    • Ingham, E. and Fisher, J. The role of macrophages in osteolysis of total joint replacement. Biomaterials, 2005, 26(11), 1271-1286.
    • (2005) Biomaterials , vol.26 , Issue.11 , pp. 1271-1286
    • Ingham, E.1    Fisher, J.2
  • 4
    • 0032949430 scopus 로고    scopus 로고
    • Analysis of 118 second-generation metal-on-metal retrieved hip joint implants
    • Sieber, H. P., Rieker, C. B., and Kottig, P. Analysis of 118 second-generation metal-on-metal retrieved hip joint implants. J. Bone Jt Surg. Br., 1999, 81(1), 46-50.
    • (1999) J. Bone Jt Surg. Br , vol.81 , Issue.1 , pp. 46-50
    • Sieber, H.P.1    Rieker, C.B.2    Kottig, P.3
  • 5
    • 9644287859 scopus 로고    scopus 로고
    • A hip joint simulator study of the performance of metal-on-metal joints
    • Dowson, D., Hardaker, C., Flett, M., and Isaac, G. A hip joint simulator study of the performance of metal-on-metal joints. J. Arthroplasty, 2004, 19(8), 118-123.
    • (2004) J. Arthroplasty , vol.19 , Issue.8 , pp. 118-123
    • Dowson, D.1    Hardaker, C.2    Flett, M.3    Isaac, G.4
  • 6
    • 0032865043 scopus 로고    scopus 로고
    • A full numerical analysis of hydrodynamic lubrication in artificial hip joint replacements constructed from hard materials
    • Jin, Z. M. and Dowson, D. A full numerical analysis of hydrodynamic lubrication in artificial hip joint replacements constructed from hard materials. Proc. Instn Mech. Engrs, Part C: J. Mechanical Engineering Science, 1999, 213(4), 355-370.
    • (1999) Proc. Instn Mech. Engrs, Part C: J. Mechanical Engineering Science , vol.213 , Issue.4 , pp. 355-370
    • Jin, Z.M.1    Dowson, D.2
  • 7
    • 0035229408 scopus 로고    scopus 로고
    • The effect of femoral head diameter upon the lubrication and wear of metal-on-metal total hip joint replacements
    • Smith, S. L., Dowson, D., and Goldsmith, A. A. The effect of femoral head diameter upon the lubrication and wear of metal-on-metal total hip joint replacements. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 215(6), 160-170.
    • (2001) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.215 , Issue.6 , pp. 160-170
    • Smith, S.L.1    Dowson, D.2    Goldsmith, A.A.3
  • 8
    • 33747109457 scopus 로고    scopus 로고
    • Effect of swing phase load on metal-on-metal hip lubrication, friction and wear
    • Williams, S., Jalali-Vahid, D., Brockett, C., Jin, Z. M., Stone, M. H., Ingham, E., and Fisher, J. Effect of swing phase load on metal-on-metal hip lubrication, friction and wear. J. Biomech., 2006, 39(12), 2274-2281.
    • (2006) J. Biomech , vol.39 , Issue.12 , pp. 2274-2281
    • Williams, S.1    Jalali-Vahid, D.2    Brockett, C.3    Jin, Z.M.4    Stone, M.H.5    Ingham, E.6    Fisher, J.7
  • 9
    • 8844224133 scopus 로고    scopus 로고
    • Lubrication modeling of artificial hip joints: From fluid film to boundary lubrication regimes
    • Manchester, July
    • Wang, F. C. and Jin, Z. M. Lubrication modeling of artificial hip joints: from fluid film to boundary lubrication regimes. In Proceedings of the ASME 7th Biennial Conference on Engineering Design and Analysis, Manchester, July 2004, EDSA2004-58078, pp. 605-611.
    • (2004) Proceedings of the ASME 7th Biennial Conference on Engineering Design and Analysis , vol.EDSA2004-58078 , pp. 605-611
    • Wang, F.C.1    Jin, Z.M.2
  • 10
    • 32844469186 scopus 로고    scopus 로고
    • Wang, F. C., Galvin, A., Jin, Z. M., Ingham, E., and Fisher, J. An integrated experimental and theoretical contact mechanics study of uhmwpe hip implants tested in a hip simulator. In Proceedings of the Third World Tribology Congress on Tribology, Washington, 2005, WTC2005-63557, pp. 311-312.
    • Wang, F. C., Galvin, A., Jin, Z. M., Ingham, E., and Fisher, J. An integrated experimental and theoretical contact mechanics study of uhmwpe hip implants tested in a hip simulator. In Proceedings of the Third World Tribology Congress on Tribology, Washington, 2005, WTC2005-63557, pp. 311-312.
  • 11
    • 23944478099 scopus 로고    scopus 로고
    • The science of metal-on-metal articulation
    • Tipper, J. L., Ingham, E., Jin, Z. M., and Fisher, J. The science of metal-on-metal articulation. Cur. Orthopaed., 2005, 19, 280-287.
    • (2005) Cur. Orthopaed , vol.19 , pp. 280-287
    • Tipper, J.L.1    Ingham, E.2    Jin, Z.M.3    Fisher, J.4
  • 12
    • 0037399485 scopus 로고    scopus 로고
    • Elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing prostheses
    • Udofia, I. J. and Jin, Z. M. Elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing prostheses. J. Biomech., 2003, 36(4), 537-544.
    • (2003) J. Biomech , vol.36 , Issue.4 , pp. 537-544
    • Udofia, I.J.1    Jin, Z.M.2
  • 13
    • 32844473949 scopus 로고    scopus 로고
    • Wang, F. C., Jin, Z. M., and Udofia, I. Elastohydrodynamic lubrication modeling of spherical metal-on-metal artificial hip joints. In Proceedings of the Third World Tribology Congress on Tribology, Washington, 2005, WTC2005-63556, pp. 489-490.
    • Wang, F. C., Jin, Z. M., and Udofia, I. Elastohydrodynamic lubrication modeling of spherical metal-on-metal artificial hip joints. In Proceedings of the Third World Tribology Congress on Tribology, Washington, 2005, WTC2005-63556, pp. 489-490.
  • 16
    • 77957773828 scopus 로고    scopus 로고
    • Kothari, M., Booker, J. F., and Bartel, D. L. Analysis of artificial hip joints as spherical bearings. In Proceedings of 21st Leeds-Lyon Symporium on Tribology, Leeds, 1995, pp. 93-98.
    • Kothari, M., Booker, J. F., and Bartel, D. L. Analysis of artificial hip joints as spherical bearings. In Proceedings of 21st Leeds-Lyon Symporium on Tribology, Leeds, 1995, pp. 93-98.
  • 18
    • 3242790341 scopus 로고    scopus 로고
    • Prediction of elastic deformation of acetabular cup and femoral head for lubrication analysis of artificial hip joints
    • Wang, F. C. and Jin, Z. M. Prediction of elastic deformation of acetabular cup and femoral head for lubrication analysis of artificial hip joints. Proc. Instn Mech. Engrs, Part J: J. Engineering Tribology, 2004, 218, 283-291.
    • (2004) Proc. Instn Mech. Engrs, Part J: J. Engineering Tribology , vol.218 , pp. 283-291
    • Wang, F.C.1    Jin, Z.M.2
  • 19
    • 27544497135 scopus 로고    scopus 로고
    • Elastohydrodynamic lubrication modeling of artificial hip joints under steady-state conditions
    • Wang, F. C. and Jin, Z. M. Elastohydrodynamic lubrication modeling of artificial hip joints under steady-state conditions. ASME J. Tribol., 2005, 127(10), 729-739.
    • (2005) ASME J. Tribol , vol.127 , Issue.10 , pp. 729-739
    • Wang, F.C.1    Jin, Z.M.2
  • 20
    • 32644434964 scopus 로고    scopus 로고
    • Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions
    • Liu, F., Jin, Z. M., Hirt, F., Rieker, C., Roberts, P., and Grigoris, P. Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions. J. Biomech., 2006, 39(6), 905-914.
    • (2006) J. Biomech , vol.39 , Issue.6 , pp. 905-914
    • Liu, F.1    Jin, Z.M.2    Hirt, F.3    Rieker, C.4    Roberts, P.5    Grigoris, P.6
  • 21
    • 77958161714 scopus 로고    scopus 로고
    • Wang, F. C. and Jin, Z. M. Lubrication modeling of artificial hip joints. IUTAM Symposium on Elastohydrodynamic and micro-elastohydrodynamic 134: solid mechanics and its applications (Eds R. W. Snidle and H. P. Evans), 2006, pp. 385-396 (Springer).
    • Wang, F. C. and Jin, Z. M. Lubrication modeling of artificial hip joints. IUTAM Symposium on Elastohydrodynamic and micro-elastohydrodynamic 134: solid mechanics and its applications (Eds R. W. Snidle and H. P. Evans), 2006, pp. 385-396 (Springer).
  • 22
    • 0036052008 scopus 로고    scopus 로고
    • Analysis of elstohydrodynamic lubrication in a novel metal-on-metal hip joint replacement
    • Jagatia, M. and Jin, Z. M. Analysis of elstohydrodynamic lubrication in a novel metal-on-metal hip joint replacement. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 216, 185-193.
    • (2001) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.216 , pp. 185-193
    • Jagatia, M.1    Jin, Z.M.2
  • 23
  • 24
    • 0042069555 scopus 로고    scopus 로고
    • The influence of lubricant and material on polymer/CoCr sliding friction
    • Yao, J. Q., Laurent, M. P., Johnson, T. S., Blanchard, C. R., and Crowinshield, R. D. The influence of lubricant and material on polymer/CoCr sliding friction. Wear, 2003, 255, 780-784.
    • (2003) Wear , vol.255 , pp. 780-784
    • Yao, J.Q.1    Laurent, M.P.2    Johnson, T.S.3    Blanchard, C.R.4    Crowinshield, R.D.5
  • 25
    • 34250614916 scopus 로고    scopus 로고
    • ISO 3290. Rolling bearing-bearing parts-ball for rolling bearings, 1975, E.
    • ISO 3290. Rolling bearing-bearing parts-ball for rolling bearings, 1975, E.
  • 27
    • 33645233305 scopus 로고    scopus 로고
    • Head replacement, head rotation, and surface damage effects on metal-on-metal total hip replacements: A hip simulator study
    • Hardaker, C., Dowson, D., and Isaac, G. H. Head replacement, head rotation, and surface damage effects on metal-on-metal total hip replacements: a hip simulator study. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(H2), 209-217.
    • (2006) Proc. IMechE, Part H: J. Engineering in Medicine , vol.220 , Issue.H2 , pp. 209-217
    • Hardaker, C.1    Dowson, D.2    Isaac, G.H.3
  • 28
    • 0019040513 scopus 로고
    • Spherical bearings: Static and dynamics analysis via the finite element method
    • Goenka, P. K. and Booker, J. F. Spherical bearings: static and dynamics analysis via the finite element method. ASME J. Lubr. Technol., 1980, 102(7), 308-319.
    • (1980) ASME J. Lubr. Technol , vol.102 , Issue.7 , pp. 308-319
    • Goenka, P.K.1    Booker, J.F.2
  • 29
    • 0037908873 scopus 로고    scopus 로고
    • Reynolds equation for spherical bearings
    • Meyer, D. M. Reynolds equation for spherical bearings. ASME J. Tribol., 2003, 125(1), 203-206.
    • (2003) ASME J. Tribol , vol.125 , Issue.1 , pp. 203-206
    • Meyer, D.M.1
  • 30
    • 33645235121 scopus 로고    scopus 로고
    • Tribological principles in metal-on-metal hip joint design
    • Dowson, D. Tribological principles in metal-on-metal hip joint design. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(H2), 161-171.
    • (2006) Proc. IMechE, Part H: J. Engineering in Medicine , vol.220 , Issue.H2 , pp. 161-171
    • Dowson, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.