메뉴 건너뛰기




Volumn 14, Issue 6, 2007, Pages 659-669

Computer-Aided Detection Systems for Breast Masses: Comparison of Performances on Full-Field Digital Mammograms and Digitized Screen-Film Mammograms

Author keywords

Computer aided detection; free response receiver operating characteristic (FROC); full field digital mammogram (FFDM); mass detection; screen film mammogram (SFM)

Indexed keywords

ADULT; AGED; ARTICLE; BREAST TUMOR; COMPUTER ASSISTED RADIOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC IMAGING; DIGITAL MAMMOGRAPHY; DISCRIMINANT ANALYSIS; HISTOGRAM; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; RADIOLOGIST;

EID: 34250164655     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2007.02.017     Document Type: Article
Times cited : (24)

References (40)
  • 1
    • 27344458270 scopus 로고    scopus 로고
    • Diagnostic performance of digital versus film mammography for breast-cancer screening
    • Pisano E.D., Gasonis C., Hendrick E., et al. Diagnostic performance of digital versus film mammography for breast-cancer screening. N Engl J Med 353 (2005) 1773-1783
    • (2005) N Engl J Med , vol.353 , pp. 1773-1783
    • Pisano, E.D.1    Gasonis, C.2    Hendrick, E.3
  • 2
    • 0035114759 scopus 로고    scopus 로고
    • Comparison of full-field digital mammography with screen-film mammography for cancer detection: results of 4,945 paired examinations
    • Lewin J.M., Hendrick R.E., D'Orsl C.J., et al. Comparison of full-field digital mammography with screen-film mammography for cancer detection: results of 4,945 paired examinations. Radiology 218 (2001) 873-880
    • (2001) Radiology , vol.218 , pp. 873-880
    • Lewin, J.M.1    Hendrick, R.E.2    D'Orsl, C.J.3
  • 3
    • 0036721482 scopus 로고    scopus 로고
    • Clinical comparison of full-field digital mammography and scree-film mammography for detection of breast cancer
    • Lewin J.M., D'Orsi C.J., Hendrick R.E., et al. Clinical comparison of full-field digital mammography and scree-film mammography for detection of breast cancer. AJR Am J Roentgenol 179 (2002) 671-677
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 671-677
    • Lewin, J.M.1    D'Orsi, C.J.2    Hendrick, R.E.3
  • 4
    • 3442902848 scopus 로고    scopus 로고
    • Diagnostic accuracy of Fischer SenoScan digital mammography versus screen-film mammography in a diagnostic mammography population
    • Cole E., Pisano E., Brown M., et al. Diagnostic accuracy of Fischer SenoScan digital mammography versus screen-film mammography in a diagnostic mammography population. Acad Radiol 11 (2004) 876-880
    • (2004) Acad Radiol , vol.11 , pp. 876-880
    • Cole, E.1    Pisano, E.2    Brown, M.3
  • 5
    • 0344153008 scopus 로고    scopus 로고
    • Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading-Oslo I Study
    • Skaane P., Young K., and Skjennald A. Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading-Oslo I Study. Radiology 229 (2003) 877-884
    • (2003) Radiology , vol.229 , pp. 877-884
    • Skaane, P.1    Young, K.2    Skjennald, A.3
  • 6
    • 2942711553 scopus 로고    scopus 로고
    • Screen-film mammography versus full-field digital mammography with soft-copy reading: randomized trial in a population-based screening program-The Oslo II Study
    • Skaane P., and Skjennald A. Screen-film mammography versus full-field digital mammography with soft-copy reading: randomized trial in a population-based screening program-The Oslo II Study. Radiology 232 (2004) 197-204
    • (2004) Radiology , vol.232 , pp. 197-204
    • Skaane, P.1    Skjennald, A.2
  • 7
    • 25144484392 scopus 로고    scopus 로고
    • Breast lesion detection and classification: comparison of screen-film mammography and full-field digital mammography with soft-copy reading-observer performance study
    • Skaane P., Balleyguier C., Diekmann F., et al. Breast lesion detection and classification: comparison of screen-film mammography and full-field digital mammography with soft-copy reading-observer performance study. Radiology 237 (2005) 37-44
    • (2005) Radiology , vol.237 , pp. 37-44
    • Skaane, P.1    Balleyguier, C.2    Diekmann, F.3
  • 8
  • 9
    • 0023270266 scopus 로고
    • Breast cancer detection: one versus two views
    • Bassett L.W., Bunnell D.H., Jahanshahi R., et al. Breast cancer detection: one versus two views. Radiology 165 (1987) 95-97
    • (1987) Radiology , vol.165 , pp. 95-97
    • Bassett, L.W.1    Bunnell, D.H.2    Jahanshahi, R.3
  • 10
    • 0025908633 scopus 로고
    • A review of false negative mammography in a symptomatic population
    • Wallis M.G., Walsh M.T., and Lee J.R. A review of false negative mammography in a symptomatic population. Clin Radiol 44 (1991) 13-15
    • (1991) Clin Radiol , vol.44 , pp. 13-15
    • Wallis, M.G.1    Walsh, M.T.2    Lee, J.R.3
  • 11
    • 0027136285 scopus 로고
    • Previous mammograms in patients with impalpable breast carcinomas: retrospective vs blinded interpretation
    • Harvey J.A., Fajardo L.L., and Innis C.A. Previous mammograms in patients with impalpable breast carcinomas: retrospective vs blinded interpretation. AJR Am J Roentgenol 161 (1993) 1167-1172
    • (1993) AJR Am J Roentgenol , vol.161 , pp. 1167-1172
    • Harvey, J.A.1    Fajardo, L.L.2    Innis, C.A.3
  • 12
    • 0026655955 scopus 로고
    • Analysis of cancers missed at screening mammography
    • Bird R.E., Wallace T.W., and Yankaskas B.C. Analysis of cancers missed at screening mammography. Radiology 184 (1992) 613-617
    • (1992) Radiology , vol.184 , pp. 613-617
    • Bird, R.E.1    Wallace, T.W.2    Yankaskas, B.C.3
  • 13
    • 0030064443 scopus 로고    scopus 로고
    • Variability in the interpretation of screening mammograms by US radiologists-findings from a national sample
    • Beam C.A., Layde P.M., and Sullivan D.C. Variability in the interpretation of screening mammograms by US radiologists-findings from a national sample. Arch Intern Med 156 (1996) 209-213
    • (1996) Arch Intern Med , vol.156 , pp. 209-213
    • Beam, C.A.1    Layde, P.M.2    Sullivan, D.C.3
  • 14
    • 0030280661 scopus 로고    scopus 로고
    • Effect of human variability on independent double reading in screening mammography
    • Beam V., Sullivan D., and Layde P. Effect of human variability on independent double reading in screening mammography. Acad Radiol 3 (1996) 891-897
    • (1996) Acad Radiol , vol.3 , pp. 891-897
    • Beam, V.1    Sullivan, D.2    Layde, P.3
  • 16
    • 0028288299 scopus 로고
    • Can computers help radiologists read mammograms?
    • Vyborny C.J. Can computers help radiologists read mammograms?. Radiology 191 (1994) 315-317
    • (1994) Radiology , vol.191 , pp. 315-317
    • Vyborny, C.J.1
  • 17
    • 0036189717 scopus 로고    scopus 로고
    • Computer-aided diagnosis of masses with full-field digital mammography
    • Li L., Clark R.A., and Thomas J.A. Computer-aided diagnosis of masses with full-field digital mammography. Acad Radiol 9 (2002) 4-12
    • (2002) Acad Radiol , vol.9 , pp. 4-12
    • Li, L.1    Clark, R.A.2    Thomas, J.A.3
  • 18
    • 0036082111 scopus 로고    scopus 로고
    • Breast cancer detection: evaluation of a mass detection algorithm for computer-aided diagnosis: experience in 263 patients
    • Petrick N., Chan H.P., Sahiner B., et al. Breast cancer detection: evaluation of a mass detection algorithm for computer-aided diagnosis: experience in 263 patients. Radiology 224 (2002) 217-224
    • (2002) Radiology , vol.224 , pp. 217-224
    • Petrick, N.1    Chan, H.P.2    Sahiner, B.3
  • 19
    • 33745149362 scopus 로고    scopus 로고
    • Two-view information fusion for improvement of computer-aided detection (CAD) of breast masses on mammograms
    • Wei J., Sahiner B., Hadjiiski L.M., et al. Two-view information fusion for improvement of computer-aided detection (CAD) of breast masses on mammograms. SPIE Proc 6144 (2006) 241-247
    • (2006) SPIE Proc , vol.6144 , pp. 241-247
    • Wei, J.1    Sahiner, B.2    Hadjiiski, L.M.3
  • 21
    • 25644432883 scopus 로고    scopus 로고
    • Computer aided detection of breast masses on full field digital mammograms
    • Wei J., Sahiner B., Hadjiiski L.M., et al. Computer aided detection of breast masses on full field digital mammograms. Med Phys 32 (2005) 2827-2838
    • (2005) Med Phys , vol.32 , pp. 2827-2838
    • Wei, J.1    Sahiner, B.2    Hadjiiski, L.M.3
  • 22
    • 0020737631 scopus 로고
    • The Laplacian pyramid as a compact image code
    • COM-31
    • Burt P.J., and Adelson E.H. The Laplacian pyramid as a compact image code. IEEE Trans Commun (1983) 337-345 COM-31
    • (1983) IEEE Trans Commun , pp. 337-345
    • Burt, P.J.1    Adelson, E.H.2
  • 23
    • 5644232131 scopus 로고    scopus 로고
    • Computer aided detection of breast masses on full-field digital mammograms: false positive reduction using gradient field analysis
    • Wei J., Sahiner B., Hadjiiski L.M., et al. Computer aided detection of breast masses on full-field digital mammograms: false positive reduction using gradient field analysis. Proc SPIE Med Imaging 5370 (2004) 992-998
    • (2004) Proc SPIE Med Imaging , vol.5370 , pp. 992-998
    • Wei, J.1    Sahiner, B.2    Hadjiiski, L.M.3
  • 24
    • 0032788506 scopus 로고    scopus 로고
    • Combined adaptive enhancement and region-growing segmentation of breast masses on digitized mammograms
    • Petrick N., Chan H.P., Sahiner B., et al. Combined adaptive enhancement and region-growing segmentation of breast masses on digitized mammograms. Med Phys 26 (1999) 1642-1654
    • (1999) Med Phys , vol.26 , pp. 1642-1654
    • Petrick, N.1    Chan, H.P.2    Sahiner, B.3
  • 25
    • 0035544613 scopus 로고    scopus 로고
    • Computer-aided characterization of mammographic masses: accuracy of mass segmentation and its effects on characterization
    • Sahiner B., Petrick N., Chan H.P., et al. Computer-aided characterization of mammographic masses: accuracy of mass segmentation and its effects on characterization. IEEE Tran Med Imaging 20 (2001) 1275-1284
    • (2001) IEEE Tran Med Imaging , vol.20 , pp. 1275-1284
    • Sahiner, B.1    Petrick, N.2    Chan, H.P.3
  • 26
    • 0030963167 scopus 로고    scopus 로고
    • False-positive reduction technique for detection of masses on digital mammograms: global and local multiresolution texture analysis
    • Wei D., Chan H.P., Petrick N., et al. False-positive reduction technique for detection of masses on digital mammograms: global and local multiresolution texture analysis. Med Phys 24 (1997) 903-914
    • (1997) Med Phys , vol.24 , pp. 903-914
    • Wei, D.1    Chan, H.P.2    Petrick, N.3
  • 28
    • 0035188627 scopus 로고    scopus 로고
    • Analysis of temporal change of mammographic features: computer-aided classification of malignant and benign breast masses
    • Hadjiiski L.M., Sahiner B., Chan H.P., et al. Analysis of temporal change of mammographic features: computer-aided classification of malignant and benign breast masses. Med Phys 28 (2001) 2309-2317
    • (2001) Med Phys , vol.28 , pp. 2309-2317
    • Hadjiiski, L.M.1    Sahiner, B.2    Chan, H.P.3
  • 29
    • 0032525017 scopus 로고    scopus 로고
    • Maximum-likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data
    • Metz C.E., Herman B.A., and Shen J.H. Maximum-likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data. Stat Med 17 (1998) 1033-1053
    • (1998) Stat Med , vol.17 , pp. 1033-1053
    • Metz, C.E.1    Herman, B.A.2    Shen, J.H.3
  • 30
    • 0033863591 scopus 로고    scopus 로고
    • Feature selection and classifier performance in computer-aided diagnosis: the effect of finite sample size
    • Sahiner B., Chan H.P., Petrick N., et al. Feature selection and classifier performance in computer-aided diagnosis: the effect of finite sample size. Med Phys 27 (2000) 1509-1522
    • (2000) Med Phys , vol.27 , pp. 1509-1522
    • Sahiner, B.1    Chan, H.P.2    Petrick, N.3
  • 31
    • 0029822853 scopus 로고    scopus 로고
    • Unified measurement of observer performance in detection and localizing target objects on images
    • Swensson R.G. Unified measurement of observer performance in detection and localizing target objects on images. Med Phys 23 (1996) 1709-1724
    • (1996) Med Phys , vol.23 , pp. 1709-1724
    • Swensson, R.G.1
  • 32
    • 0025269074 scopus 로고
    • Free-response methodology: alternate analysis and a new observer-performance experiment
    • Chakraborty D.P., and Winter L.H.L. Free-response methodology: alternate analysis and a new observer-performance experiment. Radiology 174 (1990) 873-881
    • (1990) Radiology , vol.174 , pp. 873-881
    • Chakraborty, D.P.1    Winter, L.H.L.2
  • 33
    • 4043148805 scopus 로고    scopus 로고
    • Observer studies involving detection and localization: modeling, analysis, and validation
    • Chakraborty D.P., and Berbaum K.S. Observer studies involving detection and localization: modeling, analysis, and validation. Med Phys 31 (2004) 2313-2330
    • (2004) Med Phys , vol.31 , pp. 2313-2330
    • Chakraborty, D.P.1    Berbaum, K.S.2
  • 34
    • 0011117008 scopus 로고    scopus 로고
    • Non-inferiority study of FFDM in an enriched diagnostic cohort: comparison with screen-film mammography in 625 women
    • Yaffe M.J. (Ed)
    • Hendrick R., Lewin J., D'Orsi C., et al. Non-inferiority study of FFDM in an enriched diagnostic cohort: comparison with screen-film mammography in 625 women. In: Yaffe M.J. (Ed). IWDM 2000: 5th International Workshop on Digital Mammography: Medical Physics (2001) 475-481
    • (2001) IWDM 2000: 5th International Workshop on Digital Mammography: Medical Physics , pp. 475-481
    • Hendrick, R.1    Lewin, J.2    D'Orsi, C.3
  • 36
    • 0033461791 scopus 로고    scopus 로고
    • Classifier design for computer-aided diagnosis: effects of finite sample size on the mean performance of classical and neural network classifiers
    • Chan H.P., Sahiner B., Wagner R.F., et al. Classifier design for computer-aided diagnosis: effects of finite sample size on the mean performance of classical and neural network classifiers. Med Phys 26 (1999) 2654-2668
    • (1999) Med Phys , vol.26 , pp. 2654-2668
    • Chan, H.P.1    Sahiner, B.2    Wagner, R.F.3
  • 37
    • 0032703733 scopus 로고    scopus 로고
    • Feature selection with limited datasets
    • Kupinski M.A., and Giger M.L. Feature selection with limited datasets. Med Phys 26 (1999) 2176-2182
    • (1999) Med Phys , vol.26 , pp. 2176-2182
    • Kupinski, M.A.1    Giger, M.L.2
  • 38
    • 0038094091 scopus 로고    scopus 로고
    • Computer-aided detection (CAD) on 90 biopsy-proven breast cancer cases acquired on a full-field digital mammography (FFDM) system
    • O'Shaughnessy K.F., Castellino R.A., Muller S.L., et al. Computer-aided detection (CAD) on 90 biopsy-proven breast cancer cases acquired on a full-field digital mammography (FFDM) system. Radiology 221 (2001) 471
    • (2001) Radiology , vol.221 , pp. 471
    • O'Shaughnessy, K.F.1    Castellino, R.A.2    Muller, S.L.3
  • 39
    • 0005482571 scopus 로고    scopus 로고
    • Potential contribution of computer-aided detection to the sensitivity of screening mammography
    • Warren Burhenne L.J., Wood S.A., D'Orsi C.J., et al. Potential contribution of computer-aided detection to the sensitivity of screening mammography. Radiology 215 (2000) 554-562
    • (2000) Radiology , vol.215 , pp. 554-562
    • Warren Burhenne, L.J.1    Wood, S.A.2    D'Orsi, C.J.3
  • 40
    • 15944386717 scopus 로고    scopus 로고
    • Impact of breast density on computer-aided detection for breast cancer
    • Brem R.E., Hoffmeister J.W., Rapelyea J.A., et al. Impact of breast density on computer-aided detection for breast cancer. AJR Am J Roentgenol 184 (2005) 439-444
    • (2005) AJR Am J Roentgenol , vol.184 , pp. 439-444
    • Brem, R.E.1    Hoffmeister, J.W.2    Rapelyea, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.