메뉴 건너뛰기




Volumn 67, Issue 4, 2007, Pages 413-422

Repeatability of the measurement of augmentation index in the clinical assessment of arterial stiffness using radial applanation tonometry

Author keywords

Pulse wave analysis; Radial artery; Reproducibility

Indexed keywords

ADULT; AGED; AMBULATORY MONITORING; ARTICLE; BLOOD PRESSURE MEASUREMENT; CLINICAL ARTICLE; CLINICAL ASSESSMENT; CONFIDENCE INTERVAL; CONTROLLED STUDY; CORRELATION COEFFICIENT; FEMALE; HUMAN; MALE; MEDICAL RECORD; NURSE; OBSERVER VARIATION; PRIORITY JOURNAL; PULSE RATE; REPEAT PROCEDURE; TONOMETRY;

EID: 34250162830     PISSN: 00365513     EISSN: 15027686     Source Type: Journal    
DOI: 10.1080/00365510601131946     Document Type: Article
Times cited : (23)

References (19)
  • 1
    • 0037389062 scopus 로고    scopus 로고
    • Noninvasive assessment of arterial stiffness and risk of atherosclerotic events
    • Oliver JJ, Webb DJ. Noninvasive assessment of arterial stiffness and risk of atherosclerotic events. Arterioscler Thromb Vasc Biol 2003;23:554-66.
    • (2003) Arterioscler Thromb Vasc Biol , vol.23 , pp. 554-566
    • Oliver, J.J.1    Webb, D.J.2
  • 2
    • 0036190775 scopus 로고    scopus 로고
    • Assessment of arterial stiffness in clinical practice
    • Mackenzie IS, Wilkinson IB, Cockcroft JR. Assessment of arterial stiffness in clinical practice. QJM 2002;95:67-74.
    • (2002) QJM , vol.95 , pp. 67-74
    • Mackenzie, I.S.1    Wilkinson, I.B.2    Cockcroft, J.R.3
  • 4
    • 0043268701 scopus 로고    scopus 로고
    • Clinical utility of aortic pulses and pressures calculated from applanated radial-artery pulses
    • Smulyan H, Siddiqui DS, Carlson RJ, London GM, Safar ME. Clinical utility of aortic pulses and pressures calculated from applanated radial-artery pulses. Hypertension 2003;42:150-5.
    • (2003) Hypertension , vol.42 , pp. 150-155
    • Smulyan, H.1    Siddiqui, D.S.2    Carlson, R.J.3    London, G.M.4    Safar, M.E.5
  • 6
    • 28544439732 scopus 로고    scopus 로고
    • Increased arterial wave reflections predict severe cardiovascular events in patients undergoing percutaneous coronary interventions
    • Weber T, Auer J, O'Rourke MF, Kvas E, Lassnig E, Lamm G, et al. Increased arterial wave reflections predict severe cardiovascular events in patients undergoing percutaneous coronary interventions. Eur Heart J 2005;26:2657-63.
    • (2005) Eur Heart J , vol.26 , pp. 2657-2663
    • Weber, T.1    Auer, J.2    O'Rourke, M.F.3    Kvas, E.4    Lassnig, E.5    Lamm, G.6
  • 9
    • 0042383300 scopus 로고    scopus 로고
    • Evaluation of two devices for self-measurement of blood pressure according to the international protocol: The Omron M5-I and the Omron 705IT
    • El Assaad MA, Topouchian JA, Asmar RG. Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705IT. Blood Press Monit 2003;8:127-33.
    • (2003) Blood Press Monit , vol.8 , pp. 127-133
    • El Assaad, M.A.1    Topouchian, J.A.2    Asmar, R.G.3
  • 10
    • 0034521052 scopus 로고    scopus 로고
    • A simulation-based evaluation of nine oscillometric blood pressure monitors for self-measurement
    • Ng KG. A simulation-based evaluation of nine oscillometric blood pressure monitors for self-measurement. Blood Press Monit 2000;5:297-322.
    • (2000) Blood Press Monit , vol.5 , pp. 297-322
    • KG, N.1
  • 11
    • 0029975750 scopus 로고    scopus 로고
    • Measurement error and correlation coefficients
    • Bland JM, Altman DG. Measurement error and correlation coefficients. Br Med J 1996;313:41-2.
    • (1996) Br Med J , vol.313 , pp. 41-42
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0038675123 scopus 로고    scopus 로고
    • Applying the right statistics: Analyses of measurement studies
    • Bland JM, Altman DG. Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol 2003;22:85-93.
    • (2003) Ultrasound Obstet Gynecol , vol.22 , pp. 85-93
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 0036016618 scopus 로고    scopus 로고
    • Statistical techniques for comparing measurers and methods of measurement: A critical review
    • Ludbrook J. Statistical techniques for comparing measurers and methods of measurement: a critical review. Clin Exp Pharmacol Physiol 2002;29:527-36.
    • (2002) Clin Exp Pharmacol Physiol , vol.29 , pp. 527-536
    • Ludbrook, J.1
  • 14
    • 1642535532 scopus 로고    scopus 로고
    • Arterial stiffness, wave reflections, and the risk of coronary artery disease
    • Weber T, Auer J, O'Rourke MF, Kvas E, Lassnig E, Berent R, et al. Arterial stiffness, wave reflections, and the risk of coronary artery disease. Circulation 2004;109:184-9.
    • (2004) Circulation , vol.109 , pp. 184-189
    • Weber, T.1    Auer, J.2    O'Rourke, M.F.3    Kvas, E.4    Lassnig, E.5    Berent, R.6
  • 15
    • 0036307450 scopus 로고    scopus 로고
    • Reproducibility of derived central arterial waveforms in patients with chronic renal failure
    • Savage MT, Ferro CJ, Pinder SJ, Tomson CR. Reproducibility of derived central arterial waveforms in patients with chronic renal failure. Clin Sci (Lond) 2002;103:59-65.
    • (2002) Clin Sci (Lond) , vol.103 , pp. 59-65
    • Savage, M.T.1    Ferro, C.J.2    Pinder, S.J.3    Tomson, C.R.4
  • 17
    • 0032818956 scopus 로고    scopus 로고
    • The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography
    • Siebenhofer A, Kemp C, Sutton A, Williams B. The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography. J Hum Hypertens 1999;13:625-9.
    • (1999) J Hum Hypertens , vol.13 , pp. 625-629
    • Siebenhofer, A.1    Kemp, C.2    Sutton, A.3    Williams, B.4
  • 18
    • 33747138279 scopus 로고    scopus 로고
    • Pulse-wave morphology and pulse-wave velocity in healthy human volunteers: Examination conditions
    • Frimodt-Moller M, Nielsen AH, Kamper AL, Strandgaard S. Pulse-wave morphology and pulse-wave velocity in healthy human volunteers: examination conditions. Scand J Clin Lab Invest 2006;66:385-94.
    • (2006) Scand J Clin Lab Invest , vol.66 , pp. 385-394
    • Frimodt-Moller, M.1    Nielsen, A.H.2    Kamper, A.L.3    Strandgaard, S.4
  • 19
    • 29244463325 scopus 로고    scopus 로고
    • May sub-clinical arterial disease help to better detect and treat high-risk asymptomatic individuals?
    • Simon A, Levenson J. May sub-clinical arterial disease help to better detect and treat high-risk asymptomatic individuals? J Hypertens 2005;23:1939-45.
    • (2005) J Hypertens , vol.23 , pp. 1939-1945
    • Simon, A.1    Levenson, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.