메뉴 건너뛰기




Volumn , Issue , 2006, Pages 450-454

Line arrester energy discharge duties

Author keywords

Arresters; Power distribution protection; Power system lightning effects; Power transmission protection; Surge protection

Indexed keywords

DISTRIBUTION LINES; POWER DISTRIBUTION PROTECTION; POWER SYSTEM LIGHTNING EFFECTS; SURGE ARRESTERS;

EID: 34250160568     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/TDC.2006.1668535     Document Type: Conference Paper
Times cited : (3)

References (8)
  • 2
    • 34250155450 scopus 로고    scopus 로고
    • Cigre WG 01, SC 33, Guide to Procedures for Estimating the Lightning Performance of Transmission Lines, Cigre Technical Brochure 63, October 1991.
    • Cigre WG 01, SC 33, Guide to Procedures for Estimating the Lightning Performance of Transmission Lines, Cigre Technical Brochure 63, October 1991.
  • 4
    • 0034223941 scopus 로고    scopus 로고
    • Transmission line arrester energy, cost, and risk of failure analysis for partially shielded transmission lines
    • July
    • E. J. Tarasiewicz, R. Rimmer, and A. S. Morched, "Transmission line arrester energy, cost, and risk of failure analysis for partially shielded transmission lines", IEEE Transactions on Power Delivery, vol. 15, no. 3, July 2000, pp. 919-924.
    • (2000) IEEE Transactions on Power Delivery , vol.15 , Issue.3 , pp. 919-924
    • Tarasiewicz, E.J.1    Rimmer, R.2    Morched, A.S.3
  • 5
    • 0032757725 scopus 로고    scopus 로고
    • Energy stress on transmission line arresters considering the total lightning charge distribution
    • January
    • L. Stenstrom and J. Lundquist, "Energy stress on transmission line arresters considering the total lightning charge distribution", IEEE Transactions on Power Delivery, vol. 14, no. 1, January 1999, pp. 148-151.
    • (1999) IEEE Transactions on Power Delivery , vol.14 , Issue.1 , pp. 148-151
    • Stenstrom, L.1    Lundquist, J.2
  • 7
    • 0033207795 scopus 로고    scopus 로고
    • Distribution Arrester Failures Caused by Lightning Current Flowing from Customer's Structure into Distribution Lines
    • October
    • K. Nakada, T. Wakai, H. Taniguchi, T. Kawabata, S. Yokoyama, T. Yokota, and A. Asakawa, "Distribution Arrester Failures Caused by Lightning Current Flowing from Customer's Structure into Distribution Lines", IEEE Transactions on Power Delivery, vol. 14, no. 4, October 1999, pp. 1527-1532.
    • (1999) IEEE Transactions on Power Delivery , vol.14 , Issue.4 , pp. 1527-1532
    • Nakada, K.1    Wakai, T.2    Taniguchi, H.3    Kawabata, T.4    Yokoyama, S.5    Yokota, T.6    Asakawa, A.7
  • 8
    • 0004248620 scopus 로고
    • Bonneville Power Administration, to
    • H. W. Dommel, EMTP Theory Book, Bonneville Power Administration, 1986, pp. 4-57 to 4-63.
    • (1986) EMTP Theory Book
    • Dommel, H.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.