메뉴 건너뛰기




Volumn 14, Issue 4, 1999, Pages 1527-1532

Distribution arrester failures caused by lightning current flowing from customer's structure into distribution lines

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC EQUIPMENT PROTECTION; ELECTRIC SURGES; FAILURE ANALYSIS; LIGHTNING; LIGHTNING ARRESTERS; LIGHTNING PROTECTION; OUTAGES; SURGE PROTECTION;

EID: 0033207795     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/61.796250     Document Type: Article
Times cited : (14)

References (8)
  • 1
    • 0022532072 scopus 로고
    • Distribution Surge Arrester Behavior due to Lightning Induced Voltage
    • S. Yokoyama, "Distribution Surge Arrester Behavior due to Lightning Induced Voltage", IEEE Trans. on Power Delivery, Vol. PWRD-1, No. 1, pp. 171-178, 1986.
    • (1986) IEEE Trans. on Power Delivery , vol.PWRD-1 , Issue.1 , pp. 171-178
    • Yokoyama, S.1
  • 3
    • 0024750015 scopus 로고
    • Experimental Study of Response of Power Distribution Lines to Direct Lightning Hits
    • S. Yokoyama & A. Asakawa, "Experimental Study of Response of Power Distribution Lines to Direct Lightning Hits", IEEE Trans. on Power Delivery, Vol. 4, No. 4, pp. 2242-2248, 1989.
    • (1989) IEEE Trans. on Power Delivery , vol.4 , Issue.4 , pp. 2242-2248
    • Yokoyama, S.1    Asakawa, A.2
  • 4
    • 0026899513 scopus 로고
    • Characteristics of Winter Lightning Current on Japan Sea Coast
    • K. Miyake, T. Suzuki & K. Shinjou, "Characteristics of Winter Lightning Current on Japan Sea Coast", IEEE Trans. on Power Delivery, Vol. 7, No. 3, pp. 1450-1456, 1992.
    • (1992) IEEE Trans. on Power Delivery , vol.7 , Issue.3 , pp. 1450-1456
    • Miyake, K.1    Suzuki, T.2    Shinjou, K.3
  • 5
    • 0031258321 scopus 로고    scopus 로고
    • Energy Absorption of Surge Arresters on Power Distribution Lines due to Direct Lightning Strokes - Effects of an Overhead Ground Wire and Installation Position of Surge Arresters
    • K. Nakada, T. Yokota, S. Yokoyama, A. Asakawa, M. Nakamura, H. Taniguchi & A. Hashimoto, "Energy Absorption of Surge Arresters on Power Distribution Lines due to Direct Lightning Strokes - Effects of an Overhead Ground Wire and Installation Position of Surge Arresters -", IEEE Trans., on Power Delivery, Vol. 12, No. 4, pp. 1779-1785, 1997.
    • (1997) IEEE Trans., on Power Delivery , vol.12 , Issue.4 , pp. 1779-1785
    • Nakada, K.1    Yokota, T.2    Yokoyama, S.3    Asakawa, A.4    Nakamura, M.5    Taniguchi, H.6    Hashimoto, A.7
  • 6
    • 0032186854 scopus 로고    scopus 로고
    • Analytical Study on Prevention Methods for Distribution Arrester Outages Caused by Winter Lightning
    • PE-209-PWRD-0-12-1997
    • K. Nakada, S. Yokoyama, T. Yokota, A. Asakawa, & T. Kawabata, "Analytical Study on Prevention Methods for Distribution Arrester Outages Caused by Winter Lightning", 1998 IEEE PES Winter Meeting, PE-209-PWRD-0-12-1997.
    • 1998 IEEE PES Winter Meeting
    • Nakada, K.1    Yokoyama, S.2    Yokota, T.3    Asakawa, A.4    Kawabata, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.