메뉴 건너뛰기




Volumn 19, Issue 7, 2004, Pages 809-816

2003 Hap Paul Award Paper of the International Society for Technology in Arthroplasty: Design and activity dependence of kinematics in fixed and mobile-bearing knee arthroplasties

Author keywords

fluoroscopy; gait; implant design; kinematics; knee arthroplasty; stair climbing

Indexed keywords

ARTICLE; CLIMBING; CLINICAL ARTICLE; CONTROLLED STUDY; FLUORESCENCE; GAIT; HUMAN; IMAGING; IMPLANT; KINEMATICS; KNEE; KNEE ARTHROPLASTY;

EID: 4644244730     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2004.04.011     Document Type: Article
Times cited : (139)

References (20)
  • 1
    • 0023618707 scopus 로고
    • Interaction between intrinsic knee mechanics and the knee extensor mechanism
    • Draganich L.F., Andriacchi T.P., Andersson G.B. Interaction between intrinsic knee mechanics and the knee extensor mechanism. J Orthop Res. 5:1987;539
    • (1987) J Orthop Res , vol.5 , pp. 539
    • Draganich, L.F.1    Andriacchi, T.P.2    Andersson, G.B.3
  • 2
    • 0036741192 scopus 로고    scopus 로고
    • Intraoperative measurement of knee kinematics in reconstruction of the anterior cruciate ligament
    • Bull A.M., Earnshaw P.H., Smith A., et al. Intraoperative measurement of knee kinematics in reconstruction of the anterior cruciate ligament. J Bone and Joint Surg Br. 84B:2002;1075
    • (2002) J Bone and Joint Surg Br , vol.84 , pp. 1075
    • Bull, A.M.1    Earnshaw, P.H.2    Smith, A.3
  • 3
    • 0031842422 scopus 로고    scopus 로고
    • Wear patterns on tibial plateaus from varus and valgus osteoarthritic knees
    • Harman M.K., Markovich G.D., Banks S.A., et al. Wear patterns on tibial plateaus from varus and valgus osteoarthritic knees. Clin Orthop. 352:1998;149
    • (1998) Clin Orthop , vol.352 , pp. 149
    • Harman, M.K.1    Markovich, G.D.2    Banks, S.A.3
  • 4
    • 0037729138 scopus 로고    scopus 로고
    • Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties
    • Banks S.A., Bellemans J., Nozaki H., et al. Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop. 410:2003;131
    • (2003) Clin Orthop , vol.410 , pp. 131
    • Banks, S.A.1    Bellemans, J.2    Nozaki, H.3
  • 5
    • 0036153569 scopus 로고    scopus 로고
    • Fluoroscopic analysis of deep flexion kinematics in total knee arthroplasty: The influence of posterior condylar offset
    • Bellemans J., Banks S., Victor J., et al. Fluoroscopic analysis of deep flexion kinematics in total knee arthroplasty the influence of posterior condylar offset. J Bone and Joint Surg Br. 84B:2002;50
    • (2002) J Bone and Joint Surg Br , vol.84 , pp. 50
    • Bellemans, J.1    Banks, S.2    Victor, J.3
  • 6
    • 0036080643 scopus 로고    scopus 로고
    • The effect of total knee arthroplasty design on extensor mechanism function
    • Mahoney O.M., McClung C.D., dela Rosa M.A., et al. The effect of total knee arthroplasty design on extensor mechanism function. J Arthroplasty. 17:2002;416
    • (2002) J Arthroplasty , vol.17 , pp. 416
    • Mahoney, O.M.1    McClung, C.D.2    Dela Rosa, M.A.3
  • 7
    • 0026350108 scopus 로고
    • The dominance of cyclic sliding in producing wear in total knee replacement
    • Blunn G.W., Walker P.S., Joshi A., et al. The dominance of cyclic sliding in producing wear in total knee replacement. Clin Orthop. 273:1991;253
    • (1991) Clin Orthop , vol.273 , pp. 253
    • Blunn, G.W.1    Walker, P.S.2    Joshi, A.3
  • 8
    • 0036050575 scopus 로고    scopus 로고
    • Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator
    • Benson L.C., DesJardins J.D., Harman M.K., et al. Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator. Proc Inst Mech Engrs H. 216:2002;409
    • (2002) Proc Inst Mech Engrs H , vol.216 , pp. 409
    • Benson, L.C.1    Desjardins, J.D.2    Harman, M.K.3
  • 9
    • 0035172720 scopus 로고    scopus 로고
    • Polyethylene damage and knee kinematics after total knee arthroplasty
    • Harman M.K., Banks S.A., Hodge W.A. Polyethylene damage and knee kinematics after total knee arthroplasty. Clin Orthop. 392:2001;383
    • (2001) Clin Orthop , vol.392 , pp. 383
    • Harman, M.K.1    Banks, S.A.2    Hodge, W.A.3
  • 10
    • 0030175447 scopus 로고    scopus 로고
    • Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    • Banks S.A., Hodge W.A. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng. 43:1996;638
    • (1996) IEEE Trans Biomed Eng , vol.43 , pp. 638
    • Banks, S.A.1    Hodge, W.A.2
  • 11
    • 0023415267 scopus 로고
    • Use of Cardan angles to locate rigid bodies in three-dimensional space
    • Tupling S., Pierrynowski M. Use of Cardan angles to locate rigid bodies in three-dimensional space. Med Biol Eng Comput. 25:1987;527
    • (1987) Med Biol Eng Comput , vol.25 , pp. 527
    • Tupling, S.1    Pierrynowski, M.2
  • 12
    • 0031543693 scopus 로고    scopus 로고
    • In vivo kinematics of cruciate-retaining and substituting knee arthroplasties
    • Banks S.A., Markovich G.D., Hodge W.A. In vivo kinematics of cruciate-retaining and substituting knee arthroplasties. J Arthroplasty. 12:1997;297
    • (1997) J Arthroplasty , vol.12 , pp. 297
    • Banks, S.A.1    Markovich, G.D.2    Hodge, W.A.3
  • 13
    • 0029859424 scopus 로고    scopus 로고
    • In vivo knee kinematics derived using an inverse perspective technique
    • Dennis D.A., Komistek R.D., Hoff W.A., et al. In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop. 331:1996;107
    • (1996) Clin Orthop , vol.331 , pp. 107
    • Dennis, D.A.1    Komistek, R.D.2    Hoff, W.A.3
  • 14
    • 0342804263 scopus 로고    scopus 로고
    • In vivo kinematics of total knee arthroplasty: Concave versus posterior-stabilised tibial joint surface
    • Uvehammer J., Karrholm J., Brandsson S. In vivo kinematics of total knee arthroplasty Concave versus posterior-stabilised tibial joint surface. J Bone Joint Surg Br. 82B:2000;499
    • (2000) J Bone Joint Surg Br , vol.82 , pp. 499
    • Uvehammer, J.1    Karrholm, J.2    Brandsson, S.3
  • 15
    • 0036901564 scopus 로고    scopus 로고
    • In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee replacement
    • Bertin K.C., Komistek R.D., Dennis D.A., et al. In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee replacement. J Arthroplasty. 17:2002;1040
    • (2002) J Arthroplasty , vol.17 , pp. 1040
    • Bertin, K.C.1    Komistek, R.D.2    Dennis, D.A.3
  • 16
    • 0036849435 scopus 로고    scopus 로고
    • Observations of femoral rollback in cruciate-retaining knee arthroplasty
    • Nozaki H., Banks S.A., Suguro T., et al. Observations of femoral rollback in cruciate-retaining knee arthroplasty. Clin Orthop. 404:2002;308
    • (2002) Clin Orthop , vol.404 , pp. 308
    • Nozaki, H.1    Banks, S.A.2    Suguro, T.3
  • 17
    • 0020433171 scopus 로고
    • The influence of total knee-replacement design on walking and stair-climbing
    • Andriacchi T.P., Galante J.O., Fermier R.W. The influence of total knee-replacement design on walking and stair-climbing. J Bone Joint Surg. 64A:1982;1328
    • (1982) J Bone Joint Surg , vol.64 , pp. 1328
    • Andriacchi, T.P.1    Galante, J.O.2    Fermier, R.W.3
  • 18
    • 0023754513 scopus 로고
    • Functional comparison of posterior cruciate-retained versus cruciate-sacrificed total knee arthroplasty
    • Dorr L.D., Ochsner J.L., Gronley J., et al. Functional comparison of posterior cruciate-retained versus cruciate-sacrificed total knee arthroplasty. Clin Orthop. 236:1988;36
    • (1988) Clin Orthop , vol.236 , pp. 36
    • Dorr, L.D.1    Ochsner, J.L.2    Gronley, J.3
  • 19
    • 0036713185 scopus 로고    scopus 로고
    • The effects of early rollback in total knee arthroplasty on stair stepping
    • Draganich L.F., Piotrowski G.A., Martell J., et al. The effects of early rollback in total knee arthroplasty on stair stepping. J Arthroplasty. 17:2002;723
    • (2002) J Arthroplasty , vol.17 , pp. 723
    • Draganich, L.F.1    Piotrowski, G.A.2    Martell, J.3
  • 20
    • 4644329839 scopus 로고    scopus 로고
    • Laboratory demonstration of mechanical and functional advantages of a single-radius TKA design
    • Mahoney O.M., Kinsey T., Casto S.R., et al. Laboratory demonstration of mechanical and functional advantages of a single-radius TKA design. Trans Orthop Res Soc. 69:2002;127
    • (2002) Trans Orthop Res Soc , vol.69 , pp. 127
    • Mahoney, O.M.1    Kinsey, T.2    Casto, S.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.