메뉴 건너뛰기




Volumn 22, Issue 4, 2007, Pages 515-524

Radiographic Bone Regeneration and Clinical Outcome With the Wagner SL Revision Stem. A 5-Year to 12-Year Follow-Up Study

Author keywords

bone regeneration; clinical outcome; femoral revision; Wagner stem

Indexed keywords

ADULT; AGED; ARTICLE; BONE DEFECT; BONE REGENERATION; CLINICAL ASSESSMENT; COXALGIA; FEMALE; FEMUR; FEMUR HEAD PROSTHESIS; FEMUR INTERTROCHANTERIC FRACTURE; FOLLOW UP; FRACTURE FIXATION; HEMATOMA; HIP DISLOCATION; HIP HEMATOMA; HIP RADIOGRAPHY; HUMAN; LEG FRACTURE; LEG LENGTH INEQUALITY; MALE; PAIN; PROBABILITY; PROSTHESIS FAILURE; STATISTICAL SIGNIFICANCE; WAGNER SL REVISION STEM;

EID: 34249929757     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2006.04.029     Document Type: Article
Times cited : (80)

References (31)
  • 1
    • 0027413687 scopus 로고
    • Impacted cancellous allografts and cement for revision total hip arthroplasty
    • Gie G.A., Linder L., Ling R.S., et al. Impacted cancellous allografts and cement for revision total hip arthroplasty. J Bone Joint Surg [Br] 75-B (1993) 14
    • (1993) J Bone Joint Surg [Br] , vol.75 -B , pp. 14
    • Gie, G.A.1    Linder, L.2    Ling, R.S.3
  • 2
    • 0036704087 scopus 로고    scopus 로고
    • Early complications after one hundred and forty-four consecutive hip revisions with impacted morselized allograft bone and cement
    • Ornstein E., Atroshi I., Franzèn H., et al. Early complications after one hundred and forty-four consecutive hip revisions with impacted morselized allograft bone and cement. J Bone Joint Surg [Am] 84-A (2002) 1323
    • (2002) J Bone Joint Surg [Am] , vol.84 -A , pp. 1323
    • Ornstein, E.1    Atroshi, I.2    Franzèn, H.3
  • 4
    • 0030453655 scopus 로고    scopus 로고
    • The Wagner revision stem for severe osteolysis. 31 hips followed for 1.5-5 years
    • Kolstad K., Adalberth G., Mallmin H., et al. The Wagner revision stem for severe osteolysis. 31 hips followed for 1.5-5 years. Acta Orthop Scand 67 (1996) 541
    • (1996) Acta Orthop Scand , vol.67 , pp. 541
    • Kolstad, K.1    Adalberth, G.2    Mallmin, H.3
  • 5
    • 0028524713 scopus 로고
    • The Wagner prosthesis for femoral reconstruction by transfemoral approach
    • Rinaldi E., Marenghi P., and Vaienti E. The Wagner prosthesis for femoral reconstruction by transfemoral approach. Chir Organi Mov 79 (1994) 353
    • (1994) Chir Organi Mov , vol.79 , pp. 353
    • Rinaldi, E.1    Marenghi, P.2    Vaienti, E.3
  • 6
    • 0033865559 scopus 로고    scopus 로고
    • The Wagner revision prosthesis consistently restores femoral bone structure
    • Isacson J., Stark A., and Wallensten R. The Wagner revision prosthesis consistently restores femoral bone structure. Int Orthop 24 (2000) 139
    • (2000) Int Orthop , vol.24 , pp. 139
    • Isacson, J.1    Stark, A.2    Wallensten, R.3
  • 7
    • 1842366661 scopus 로고    scopus 로고
    • Three- to 7-year results with the uncemented SL femoral revision prosthesis
    • Grünig R., Morscher E., and Ochsner P.E. Three- to 7-year results with the uncemented SL femoral revision prosthesis. Arch Orthop Trauma Surg 116 (1997) 187
    • (1997) Arch Orthop Trauma Surg , vol.116 , pp. 187
    • Grünig, R.1    Morscher, E.2    Ochsner, P.E.3
  • 8
    • 0034924526 scopus 로고    scopus 로고
    • Femoral revision with the Wagner SL revision stem, evaluation of one hundred and twenty-nine revisions followed for a mean of 4.8 years
    • Bohm P., and Bischel O. Femoral revision with the Wagner SL revision stem, evaluation of one hundred and twenty-nine revisions followed for a mean of 4.8 years. J Bone Joint Surg [Am] 83-A (2001) 1023
    • (2001) J Bone Joint Surg [Am] , vol.83 -A , pp. 1023
    • Bohm, P.1    Bischel, O.2
  • 9
    • 0028566630 scopus 로고
    • Revision THR after periprosthetic femoral fractures. An analysis of 23 cases
    • Koldstad K. Revision THR after periprosthetic femoral fractures. An analysis of 23 cases. Acta Orthop Scand 65 (1994) 505
    • (1994) Acta Orthop Scand , vol.65 , pp. 505
    • Koldstad, K.1
  • 10
    • 0037591631 scopus 로고    scopus 로고
    • Distal fixation with Wagner revision stem in treating Vancouver type B2 periprosthetic femur fractures in geriatric patients
    • Ko P.S., Lam J.J., Tio M.K., et al. Distal fixation with Wagner revision stem in treating Vancouver type B2 periprosthetic femur fractures in geriatric patients. J Arthroplasty 18 (2003) 446
    • (2003) J Arthroplasty , vol.18 , pp. 446
    • Ko, P.S.1    Lam, J.J.2    Tio, M.K.3
  • 11
    • 0029385677 scopus 로고
    • Revisión of the femoral prosthetic component according to the Wagner technique
    • Ponziani L., Rollo G., Bungaro P., et al. Revisión of the femoral prosthetic component according to the Wagner technique. Chir Organi Mov 80 (1995) 385
    • (1995) Chir Organi Mov , vol.80 , pp. 385
    • Ponziani, L.1    Rollo, G.2    Bungaro, P.3
  • 12
    • 0035069859 scopus 로고    scopus 로고
    • Bone reconstruction, leg length discrepancy, and dislocation rate in 52 Wagner revision total hip arthroplasty at 44-month follow-up
    • Boisgard S., Moreau P.E., Tixier H., et al. Bone reconstruction, leg length discrepancy, and dislocation rate in 52 Wagner revision total hip arthroplasty at 44-month follow-up. Rev Chir Orthop 87 (2001) 147
    • (2001) Rev Chir Orthop , vol.87 , pp. 147
    • Boisgard, S.1    Moreau, P.E.2    Tixier, H.3
  • 13
    • 0033658127 scopus 로고    scopus 로고
    • Hip replacement: treatment of femoral bone loss using distal bypass fixation
    • Paprosky W.G., and Aribindi R. Hip replacement: treatment of femoral bone loss using distal bypass fixation. ICL 49 (2000) 119
    • (2000) ICL , vol.49 , pp. 119
    • Paprosky, W.G.1    Aribindi, R.2
  • 14
    • 77049159486 scopus 로고
    • Functional results of hip arthroplasty with acrylic prótesis
    • Merle D'Aubigné R., and Postel M. Functional results of hip arthroplasty with acrylic prótesis. J Bone Joint Surg [Am] 36-A (1954) 451
    • (1954) J Bone Joint Surg [Am] , vol.36 -A , pp. 451
    • Merle D'Aubigné, R.1    Postel, M.2
  • 15
    • 0026356911 scopus 로고
    • Comparison of porous-threaded and smooth threaded acetabular components of identical design. Two- to four-year results
    • Pupparo F., and Engh C.A. Comparison of porous-threaded and smooth threaded acetabular components of identical design. Two- to four-year results. Clin Orthop 271 (1991) 201
    • (1991) Clin Orthop , vol.271 , pp. 201
    • Pupparo, F.1    Engh, C.A.2
  • 16
    • 0025270925 scopus 로고
    • Clinical and radiographic evaluation of total hip arthroplasty. A standard system of terminology for reporting results
    • Johnston R.C., Fitzgerald R.H., Harris W.H., et al. Clinical and radiographic evaluation of total hip arthroplasty. A standard system of terminology for reporting results. J Bone Joint Surg [Am] 72-A (1990) 161
    • (1990) J Bone Joint Surg [Am] , vol.72 -A , pp. 161
    • Johnston, R.C.1    Fitzgerald, R.H.2    Harris, W.H.3
  • 17
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components
    • Gruen T.A., McNeice G.M., and Amstutz H.C. "Modes of failure" of cemented stem-type femoral components. Clin Orthop 171 (1979) 17
    • (1979) Clin Orthop , vol.171 , pp. 17
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 18
    • 0141646517 scopus 로고    scopus 로고
    • Fractures at the tip of long-stem prostheses used for revision hip arthroplasty
    • Zalzal P., Gandhi R., Petruccelli D., et al. Fractures at the tip of long-stem prostheses used for revision hip arthroplasty. J Arthroplasty 18 (2003) 741
    • (2003) J Arthroplasty , vol.18 , pp. 741
    • Zalzal, P.1    Gandhi, R.2    Petruccelli, D.3
  • 19
    • 0021817452 scopus 로고
    • Results of revision for mechanical failure after cemented total hip replacement. 1979 to 1982. A two to five-year follow-up
    • Callaghan J.J., Salvati E.A., Pellicci P.M., et al. Results of revision for mechanical failure after cemented total hip replacement. 1979 to 1982. A two to five-year follow-up. J Bone Joint Surg [Am] 67-A (1985) 1074
    • (1985) J Bone Joint Surg [Am] , vol.67 -A , pp. 1074
    • Callaghan, J.J.1    Salvati, E.A.2    Pellicci, P.M.3
  • 20
    • 0025695691 scopus 로고
    • The case for porous-coated hip implants. The femoral side
    • Engh C.A., Glassman A.H., and Suthers K.E. The case for porous-coated hip implants. The femoral side. Clin Orthop 261 (1990) 63
    • (1990) Clin Orthop , vol.261 , pp. 63
    • Engh, C.A.1    Glassman, A.H.2    Suthers, K.E.3
  • 21
    • 33845382806 scopus 로고
    • Nonparametric estimation from incomplete observations
    • Kaplan E.L., and Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc 53 (1958) 457
    • (1958) J Am Stat Assoc , vol.53 , pp. 457
    • Kaplan, E.L.1    Meier, P.2
  • 22
    • 0022976577 scopus 로고
    • Survivorship analysis in the evaluation of joint replacement
    • Dorey F., and Amstutz H.C. Survivorship analysis in the evaluation of joint replacement. J Arthroplasty 1 (1986) 63
    • (1986) J Arthroplasty , vol.1 , pp. 63
    • Dorey, F.1    Amstutz, H.C.2
  • 25
    • 0028841202 scopus 로고
    • Femoral revision hip arthroplasty with uncemented, porous-coated stems
    • Moreland J.R., and Bernstein M.L. Femoral revision hip arthroplasty with uncemented, porous-coated stems. Clin Orthop 319 (1995) 141
    • (1995) Clin Orthop , vol.319 , pp. 141
    • Moreland, J.R.1    Bernstein, M.L.2
  • 26
    • 0031911426 scopus 로고    scopus 로고
    • Revision of loose cementless femoral prostheses to larger porous coated components
    • Engh C.A., Culpepper W.J., and Kassapidis E. Revision of loose cementless femoral prostheses to larger porous coated components. Clin Orthop 347 (1998) 168
    • (1998) Clin Orthop , vol.347 , pp. 168
    • Engh, C.A.1    Culpepper, W.J.2    Kassapidis, E.3
  • 27
    • 0345060423 scopus 로고    scopus 로고
    • Revision total hip arthroplasty. The limits of fully coated stems
    • Sporer S.M., and Paprosky W.G. Revision total hip arthroplasty. The limits of fully coated stems. Clin Orthop 417 (2003) 203
    • (2003) Clin Orthop , vol.417 , pp. 203
    • Sporer, S.M.1    Paprosky, W.G.2
  • 28
    • 9644268065 scopus 로고    scopus 로고
    • Femoral fixation in the face of considerable bone loss. The use of modular stems
    • Sporer S.M., and Paprosky W.G. Femoral fixation in the face of considerable bone loss. The use of modular stems. Clin Orthop 429 (2004) 227
    • (2004) Clin Orthop , vol.429 , pp. 227
    • Sporer, S.M.1    Paprosky, W.G.2
  • 29
    • 0036083992 scopus 로고    scopus 로고
    • Femoral revision. Distal fixation with fluted, tapered grit-blasted stems
    • Berry D.J. Femoral revision. Distal fixation with fluted, tapered grit-blasted stems. J Arthroplasty 17 Suppl 1 (2002) 142
    • (2002) J Arthroplasty , vol.17 , Issue.SUPPL. 1 , pp. 142
    • Berry, D.J.1
  • 30
    • 0000938733 scopus 로고    scopus 로고
    • Hip prosthesis revision with the non-cemented femoral revision stem-10 year experience
    • Wagner H., and Wagner M. Hip prosthesis revision with the non-cemented femoral revision stem-10 year experience. Med Orthop Tech 117 (1997) 138
    • (1997) Med Orthop Tech , vol.117 , pp. 138
    • Wagner, H.1    Wagner, M.2
  • 31
    • 0344629806 scopus 로고    scopus 로고
    • Treatment of Vancouver B3 periprosthetic femur fractures with a fluted tapered stem
    • Berry D.J. Treatment of Vancouver B3 periprosthetic femur fractures with a fluted tapered stem. Clin Orthop 417 (2003) 224
    • (2003) Clin Orthop , vol.417 , pp. 224
    • Berry, D.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.