메뉴 건너뛰기




Volumn 60, Issue 5, 2007, Pages 565-566

Falsely normal C4 in a case of acquired C1 esterase inhibitor deficiency

Author keywords

[No Author keywords available]

Indexed keywords

C REACTIVE PROTEIN; CHLORAMBUCIL; COMPLEMENT COMPONENT C1S INHIBITOR; HEMOGLOBIN; IMMUNOGLOBULIN G ANTIBODY; IMMUNOGLOBULIN KAPPA CHAIN; LACTATE DEHYDROGENASE; MERCAPTOETHANOL; MONOCLONAL ANTIBODY; PARAPROTEIN; PREDNISOLONE; TRANEXAMIC ACID; VIPER VENOM;

EID: 34249871376     PISSN: 00219746     EISSN: None     Source Type: Journal    
DOI: 10.1136/jcp.2006.041350     Document Type: Article
Times cited : (7)

References (13)
  • 1
    • 0035159206 scopus 로고    scopus 로고
    • False increase in serum C-reactive protein caused by monoclonal IgM-lambda: A case report
    • Yu A, Pira U. False increase in serum C-reactive protein caused by monoclonal IgM-lambda: a case report. Clin Chem Lab Med 2001;39:983-7.
    • (2001) Clin Chem Lab Med , vol.39 , pp. 983-987
    • Yu, A.1    Pira, U.2
  • 2
    • 20044384875 scopus 로고    scopus 로고
    • C1 inhibitor deficiency: Consensus document
    • Gompels MM, Lock RJ, Abinun M, et al. C1 inhibitor deficiency: consensus document. Clin Exp Immunol 2005;139:379-94.
    • (2005) Clin Exp Immunol , vol.139 , pp. 379-394
    • Gompels, M.M.1    Lock, R.J.2    Abinun, M.3
  • 3
    • 0036162030 scopus 로고    scopus 로고
    • A multicentre evaluation of the diagnostic efficiency of serological investigations for C1 inhibitor deficiency
    • Gompels MM, Lock RJ, Morgan JE, et al. A multicentre evaluation of the diagnostic efficiency of serological investigations for C1 inhibitor deficiency. J Clin Pathol 2002;55:145-7.
    • (2002) J Clin Pathol , vol.55 , pp. 145-147
    • Gompels, M.M.1    Lock, R.J.2    Morgan, J.E.3
  • 5
    • 11144296752 scopus 로고    scopus 로고
    • Protein precipitation as a possible important pitfall in the clinical chemistry analysis of blood samples containing monoclonal immunoglobulins: 2 case reports and a review of the literature
    • Berth M, Delanghe J. Protein precipitation as a possible important pitfall in the clinical chemistry analysis of blood samples containing monoclonal immunoglobulins: 2 case reports and a review of the literature. Acta Clin Belg 2004;59:263-73.
    • (2004) Acta Clin Belg , vol.59 , pp. 263-273
    • Berth, M.1    Delanghe, J.2
  • 6
    • 19644386499 scopus 로고    scopus 로고
    • Paraprotein interference in automated chemistry analyzers
    • Sheppard CA, Allen RC, Austin GE, et al. Paraprotein interference in automated chemistry analyzers. Clin Chem 2005;51:1077-8.
    • (2005) Clin Chem , vol.51 , pp. 1077-1078
    • Sheppard, C.A.1    Allen, R.C.2    Austin, G.E.3
  • 7
    • 0031309449 scopus 로고    scopus 로고
    • Interference with nephelometric assay of C-reactive protein and antistreptolysin-O by monoclonal IgM-κ from a myeloma patient
    • Yamada K, Yagihashi A, Ishii S, et al. Interference with nephelometric assay of C-reactive protein and antistreptolysin-O by monoclonal IgM-κ from a myeloma patient. Clin Chem 1997;43:2435-7.
    • (1997) Clin Chem , vol.43 , pp. 2435-2437
    • Yamada, K.1    Yagihashi, A.2    Ishii, S.3
  • 8
    • 0031804043 scopus 로고    scopus 로고
    • Interference with nephelometric assay of C-reactive protein by monoclonal immunoglobulin
    • Lammers M. Interference with nephelometric assay of C-reactive protein by monoclonal immunoglobulin. Clin Chem 1998;44:1584-5.
    • (1998) Clin Chem , vol.44 , pp. 1584-1585
    • Lammers, M.1
  • 9
    • 33646782278 scopus 로고    scopus 로고
    • Multiple autoimmune phenomena in splenic marginal zone lymphoma
    • Ziakas PD, Giannouli S, Tasidou A, et al. Multiple autoimmune phenomena in splenic marginal zone lymphoma. Leuk Lymphoma 2006;47:772-5.
    • (2006) Leuk Lymphoma , vol.47 , pp. 772-775
    • Ziakas, P.D.1    Giannouli, S.2    Tasidou, A.3
  • 10
    • 0032754645 scopus 로고    scopus 로고
    • False-positive reactions for IgA anti-phospholipid and anti-beta(2)-glycoprotein I antibodies in patients with IgA monoclonal gammopathy
    • Bizzaro N, Pasini P, Finco B. False-positive reactions for IgA anti-phospholipid and anti-beta(2)-glycoprotein I antibodies in patients with IgA monoclonal gammopathy. Clin Chem 1999;45:2007-10.
    • (1999) Clin Chem , vol.45 , pp. 2007-2010
    • Bizzaro, N.1    Pasini, P.2    Finco, B.3
  • 11
    • 0028038346 scopus 로고
    • Rheumatic autoantibodies in the sera of patients with paraproteins
    • Hardiman KL, Horn S, Manoharan A, et al. Rheumatic autoantibodies in the sera of patients with paraproteins. Clin Exp Rheumatol 1994;12:363-8.
    • (1994) Clin Exp Rheumatol , vol.12 , pp. 363-368
    • Hardiman, K.L.1    Horn, S.2    Manoharan, A.3
  • 12
    • 0024687957 scopus 로고
    • Hypergammaglobulinemia and the anticardiolipin antibody test
    • Hughes TP, Jones P, Rozenberg MC. Hypergammaglobulinemia and the anticardiolipin antibody test. Arthritis Rheum 1989;32:813.
    • (1989) Arthritis Rheum , vol.32 , pp. 813
    • Hughes, T.P.1    Jones, P.2    Rozenberg, M.C.3
  • 13
    • 0023682832 scopus 로고
    • False positive ELISA tests for anticardiolipin antibodies in sera from patients with repeated abortion, rheumatologic disorders and primary biliary cirrhosis: Correlation with elevated polyclonal IgM and implications for patients with repeated abortion
    • Cowchock S, Fort J, Munoz S, et al. False positive ELISA tests for anticardiolipin antibodies in sera from patients with repeated abortion, rheumatologic disorders and primary biliary cirrhosis: correlation with elevated polyclonal IgM and implications for patients with repeated abortion. Clin Exp Immunol 1988;73:289-94.
    • (1988) Clin Exp Immunol , vol.73 , pp. 289-294
    • Cowchock, S.1    Fort, J.2    Munoz, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.