메뉴 건너뛰기




Volumn 7, Issue 3, 2007, Pages 460-467

Problem of stress shielding and improvement to the hip implant designs: A review

Author keywords

Bone loss; Hip joint replacement; Implant design; Stress shielding

Indexed keywords

ALUMINUM OXIDE; BIOMATERIAL; CHROMIUM; COBALT; MOLYBDENUM; POLITEF; POLYETHYLENE; ZIRCONIUM OXIDE;

EID: 34249854037     PISSN: 16824474     EISSN: 18125727     Source Type: Journal    
DOI: 10.3923/jms.2007.460.467     Document Type: Review
Times cited : (251)

References (36)
  • 1
    • 0034333761 scopus 로고    scopus 로고
    • A model of bone adaptation as an optimization process
    • Bagge, M., 2000. A model of bone adaptation as an optimization process. J. Biomechanics, 33: 1349-1357.
    • (2000) J. Biomechanics , vol.33 , pp. 1349-1357
    • Bagge, M.1
  • 2
    • 7044238389 scopus 로고    scopus 로고
    • The effect of muscle loading on the simulation of bone remodelling in the proximal femur
    • Bitsakos, C., J. Kerner, I. Fisher and A.A. Amis, 2005. The effect of muscle loading on the simulation of bone remodelling in the proximal femur. J. Biomechanics, 38: 133-139.
    • (2005) J. Biomechanics , vol.38 , pp. 133-139
    • Bitsakos, C.1    Kerner, J.2    Fisher, I.3    Amis, A.A.4
  • 3
    • 0025695692 scopus 로고
    • The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty
    • Bobyn, J.D., A.H. Glassman, H. Goto, J.J. Krygier, J.E. Miller and C.E. Brooks, 1990. The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty. Clin. Orthopaedics, 261: 196-213.
    • (1990) Clin. Orthopaedics , vol.261 , pp. 196-213
    • Bobyn, J.D.1    Glassman, A.H.2    Goto, H.3    Krygier, J.J.4    Miller, J.E.5    Brooks, C.E.6
  • 4
    • 1942434585 scopus 로고    scopus 로고
    • Review of wear mechanisms in hip implants: Paper I-General
    • Buford, A. and T. Goswami, 2004. Review of wear mechanisms in hip implants: Paper I-General. Materials and Design, 25: 385-393.
    • (2004) Materials and Design , vol.25 , pp. 385-393
    • Buford, A.1    Goswami, T.2
  • 5
    • 0029972210 scopus 로고    scopus 로고
    • Bone remodeling around cementless hip implants
    • Bugbee, W.D., C.J. Sychterz and C.A. Bugh, 1996. Bone remodeling around cementless hip implants. Southern Med. J., 89: 1036-1040.
    • (1996) Southern Med. J , vol.89 , pp. 1036-1040
    • Bugbee, W.D.1    Sychterz, C.J.2    Bugh, C.A.3
  • 6
    • 0034947534 scopus 로고    scopus 로고
    • Environmental variables design and analysis of robust total joint replacements: Finite element model experiments with environmental variables
    • Chang, P.B., B.J. Williams, K.S.B. Bhalla, T.W. Belknap, T.J. Santner, I.W. Notz and D.L. Bartel, 2001. Environmental variables design and analysis of robust total joint replacements: Finite element model experiments with environmental variables. J. Biomechanical Eng., 123: 239-246.
    • (2001) J. Biomechanical Eng , vol.123 , pp. 239-246
    • Chang, P.B.1    Williams, B.J.2    Bhalla, K.S.B.3    Belknap, T.W.4    Santner, T.J.5    Notz, I.W.6    Bartel, D.L.7
  • 7
    • 0024385563 scopus 로고
    • Initial effect of collarless stem stiffness on femoral bone strain
    • Diegel, P.D., A.U. Daniels and H.K. Dunn, 1989. Initial effect of collarless stem stiffness on femoral bone strain. J. Arthroplasty, 4: 173-178.
    • (1989) J. Arthroplasty , vol.4 , pp. 173-178
    • Diegel, P.D.1    Daniels, A.U.2    Dunn, H.K.3
  • 8
    • 0034930093 scopus 로고    scopus 로고
    • A finite element analysis of hollow stemmed hip prostheses as a means of reducing stress shielding of the femur
    • Gross, S. and E.W. Abel, 2001. A finite element analysis of hollow stemmed hip prostheses as a means of reducing stress shielding of the femur. J. Biomechanics, 34: 995-1003.
    • (2001) J. Biomechanics , vol.34 , pp. 995-1003
    • Gross, S.1    Abel, E.W.2
  • 10
    • 0026604141 scopus 로고
    • The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
    • Huiskes, H.W.J., H. Weinans and B. van Rietbergen, 1992. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin. Orthopaedics, 274: 124-134.
    • (1992) Clin. Orthopaedics , vol.274 , pp. 124-134
    • Huiskes, H.W.J.1    Weinans, H.2    van Rietbergen, B.3
  • 11
    • 0027748808 scopus 로고
    • Stress shielding and bone resorption in THA: Clinical versus computer-simulation studies
    • Huiskes, R., 1993. Stress shielding and bone resorption in THA: Clinical versus computer-simulation studies. Acta Orthopaedica Belgia, 59: 118-129.
    • (1993) Acta Orthopaedica Belgia , vol.59 , pp. 118-129
    • Huiskes, R.1
  • 12
    • 0036023508 scopus 로고    scopus 로고
    • Clinical outcome in total hip arthroplasty using a cemented Titanium femoral prosthesis
    • Jergesen, H.E. and J.W. Karlen, 2002. Clinical outcome in total hip arthroplasty using a cemented Titanium femoral prosthesis. J. Arthroplasty, 17: 592-599.
    • (2002) J. Arthroplasty , vol.17 , pp. 592-599
    • Jergesen, H.E.1    Karlen, J.W.2
  • 13
    • 0033816740 scopus 로고    scopus 로고
    • Analysis of a femoral hip prosthesis designed to reduce stress shielding
    • Joshi, M.G., S.G. Advani, F. Miller and M.H. Santare, 2000. Analysis of a femoral hip prosthesis designed to reduce stress shielding. J. Biomechanics, 33: 1655-1662.
    • (2000) J. Biomechanics , vol.33 , pp. 1655-1662
    • Joshi, M.G.1    Advani, S.G.2    Miller, F.3    Santare, M.H.4
  • 15
    • 2642556592 scopus 로고    scopus 로고
    • Comparison of in situ and in vitro CT scan-based finite element model predictions of femoral fracture load
    • Keyak, J.H. and Y. Falkinstein, 2003. Comparison of in situ and in vitro CT scan-based finite element model predictions of femoral fracture load. Med. Eng. Phys., 25: 781-787.
    • (2003) Med. Eng. Phys , vol.25 , pp. 781-787
    • Keyak, J.H.1    Falkinstein, Y.2
  • 17
    • 0037260875 scopus 로고    scopus 로고
    • Patients' reasons for undergoing total hip arthroplasty can change over time
    • Lieberman, J.R., B.J. Thomas, G.A.M. Finerman and F. Dorey, 2003. Patients' reasons for undergoing total hip arthroplasty can change over time. J. Arthroplasty, 18: 63-68.
    • (2003) J. Arthroplasty , vol.18 , pp. 63-68
    • Lieberman, J.R.1    Thomas, B.J.2    Finerman, G.A.M.3    Dorey, F.4
  • 19
    • 0027381820 scopus 로고
    • Prognosis of total hip replacement in Sweden. Follow-up of 92,675 operations performed 1978-1990
    • Malchau, H., P. Herberts and L. Ahnfelt, 1993. Prognosis of total hip replacement in Sweden. Follow-up of 92,675 operations performed 1978-1990. Acta Orthopaedica Scandinavica, 64: 97-506.
    • (1993) Acta Orthopaedica Scandinavica , vol.64 , pp. 97-506
    • Malchau, H.1    Herberts, P.2    Ahnfelt, L.3
  • 21
    • 0025653959 scopus 로고
    • Effects of hollow shaft endoprosthesis on stress distribution in cortical bone
    • Mattheck, C., U. Vorberg and C. Kranz, 1990. Effects of hollow shaft endoprosthesis on stress distribution in cortical bone. Biomed. Eng., 35: 316-319.
    • (1990) Biomed. Eng , vol.35 , pp. 316-319
    • Mattheck, C.1    Vorberg, U.2    Kranz, C.3
  • 23
    • 0029347467 scopus 로고
    • Fixation and effect on bone strain pattern of a stemless hip prosthesis
    • Munting, E. and M. Verhelpen, 1995. Fixation and effect on bone strain pattern of a stemless hip prosthesis. J. Biomechanics, 28: 949-961.
    • (1995) J. Biomechanics , vol.28 , pp. 949-961
    • Munting, E.1    Verhelpen, M.2
  • 24
    • 0342527610 scopus 로고    scopus 로고
    • A proximal fixed anatomic femoral stem reduces stress shielding
    • Niinimäki, T. J. Junila and P. Jalovaara, 2001. A proximal fixed anatomic femoral stem reduces stress shielding. Intl. Orthopaedics, 25: 85-88.
    • (2001) Intl. Orthopaedics , vol.25 , pp. 85-88
    • Niinimäki, T.J.J.1    Jalovaara, P.2
  • 25
    • 0037371494 scopus 로고    scopus 로고
    • Primary and revision total hip arthroplasty for patients 90 years of age and older
    • Pagnano, M.W., L.A. McLamb and R.T. Trousdale, 2003. Primary and revision total hip arthroplasty for patients 90 years of age and older. Mayo Clin. Proc., 78: 285-288.
    • (2003) Mayo Clin. Proc , vol.78 , pp. 285-288
    • Pagnano, M.W.1    McLamb, L.A.2    Trousdale, R.T.3
  • 26
    • 0033119355 scopus 로고    scopus 로고
    • Strength requirements for internal and external prostheses
    • Paul, J.P., 1999. Strength requirements for internal and external prostheses. J. Biomechanics, 32: 381-393.
    • (1999) J. Biomechanics , vol.32 , pp. 381-393
    • Paul, J.P.1
  • 29
    • 0035216878 scopus 로고    scopus 로고
    • Load transfer and stress shielding of the hydroxyapatite-ABG hip: A study of stem length and proximal fixation
    • Rietbergen, B.V. and R. Huiskes, 2001. Load transfer and stress shielding of the hydroxyapatite-ABG hip: A study of stem length and proximal fixation. J. Arthroplasty, 16: 55-63.
    • (2001) J. Arthroplasty , vol.16 , pp. 55-63
    • Rietbergen, B.V.1    Huiskes, R.2
  • 30
    • 0028212530 scopus 로고
    • The Cenos hollow stem in total hip arthroplasty: First experiences in a prospective study
    • Schmidt, J. and M.H. Hackenbroch, 1994. The Cenos hollow stem in total hip arthroplasty: First experiences in a prospective study. Arch. Orthopaed. Trauma Surg., 113: 117-120.
    • (1994) Arch. Orthopaed. Trauma Surg , vol.113 , pp. 117-120
    • Schmidt, J.1    Hackenbroch, M.H.2
  • 31
    • 0026560894 scopus 로고
    • Determinants of stress shielding: Design versus materials versus interface
    • Sumner, D.R. and J.O. Galante, 1992. Determinants of stress shielding: Design versus materials versus interface. Clin. Orthopaed. Related Res., 274: 202-212.
    • (1992) Clin. Orthopaed. Related Res , vol.274 , pp. 202-212
    • Sumner, D.R.1    Galante, J.O.2
  • 33
    • 34249846479 scopus 로고    scopus 로고
    • Swanson, S.A.V., 1977. Mechanical Aspects of Fixation. The Scientific Basis of Joint Replacement, Swanson S.A.V. and M.A.R. Freeman (Eds.), Pitman Medical Publishers, Tumbridge Wells, pp: 130-157.
    • Swanson, S.A.V., 1977. Mechanical Aspects of Fixation. The Scientific Basis of Joint Replacement, Swanson S.A.V. and M.A.R. Freeman (Eds.), Pitman Medical Publishers, Tumbridge Wells, pp: 130-157.
  • 34
    • 33644611493 scopus 로고    scopus 로고
    • Assessment of periprosthetic bone loss after total hip arthroplasty
    • Tang, H., Y. Jiang, X.Z. Luo, S.M. Ren and H.K. Genant, 2002. Assessment of periprosthetic bone loss after total hip arthroplasty. Chin. Med. J., 115: 510-513.
    • (2002) Chin. Med. J , vol.115 , pp. 510-513
    • Tang, H.1    Jiang, Y.2    Luo, X.Z.3    Ren, S.M.4    Genant, H.K.5
  • 36
    • 0034071250 scopus 로고    scopus 로고
    • Sensitivity of periprosthetic stress-shielding to load and the bone density-modulus relationship in subject-specific finite element models
    • Weinans, H., D.R. Sumner, R. Igloria and R.N. Natarajan, 2000. Sensitivity of periprosthetic stress-shielding to load and the bone density-modulus relationship in subject-specific finite element models. J. Biomechanics, 33: 809-817.
    • (2000) J. Biomechanics , vol.33 , pp. 809-817
    • Weinans, H.1    Sumner, D.R.2    Igloria, R.3    Natarajan, R.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.