메뉴 건너뛰기




Volumn 25, Issue 2, 2001, Pages 85-88

A proximal fixed anatomic femoral stem reduces stress shielding

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BONE ATROPHY; BONE DENSITY; BONE MINERAL; BONE STRESS; CLINICAL ARTICLE; CONTROLLED STUDY; DEVICE; DIAPHYSIS; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; FEMUR SHAFT; FOLLOW UP; HUMAN; MALE; MEASUREMENT; METAPHYSIS; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; SURGICAL TECHNIQUE; TOTAL HIP PROSTHESIS; TREATMENT OUTCOME;

EID: 0342527610     PISSN: 03412695     EISSN: None     Source Type: Journal    
DOI: 10.1007/s002640100241     Document Type: Article
Times cited : (42)

References (16)
  • 1
    • 84964187820 scopus 로고
    • Measurement of feelings using visual analogue scales
    • Aitken RC (1969) Measurement of feelings using visual analogue scales. Proc R Soc Med 62:989-993
    • (1969) Proc R Soc Med , vol.62 , pp. 989-993
    • Aitken, R.C.1
  • 2
    • 0026519501 scopus 로고
    • Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty
    • Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE (1992) Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop 274:79-96
    • (1992) Clin Orthop , vol.274 , pp. 79-96
    • Bobyn, J.D.1    Mortimer, E.S.2    Glassman, A.H.3    Engh, C.A.4    Miller, J.E.5    Brooks, C.E.6
  • 3
    • 0015754154 scopus 로고
    • Ectopic ossification following total hip replacement: Incidence and a method of classification
    • Brooker AF, Bowerman JW, Robinson RA, Riley LH (1973) Ectopic ossification following total hip replacement: incidence and a method of classification. J Bone Joint Surg [Am] 55: 1629-1632
    • (1973) J Bone Joint Surg [Am] , vol.55 , pp. 1629-1632
    • Brooker, A.F.1    Bowerman, J.W.2    Robinson, R.A.3    Riley, L.H.4
  • 4
    • 0026795145 scopus 로고
    • A quantitative evaluation of periprosthesis remodelling after cementless total hip arthroplasty
    • Engh CA, McGovern TF, Bobyn JD, Harris WH (1992) A quantitative evaluation of periprosthesis remodelling after cementless total hip arthroplasty. J Bone Joint Surg [Br] 74: 1009-1020
    • (1992) J Bone Joint Surg [Br] , vol.74 , pp. 1009-1020
    • Engh, C.A.1    McGovern, T.F.2    Bobyn, J.D.3    Harris, W.H.4
  • 5
    • 0018687995 scopus 로고
    • "Modes of failures" of cemented stem-type femoral components: A radiographic analysis of loosening
    • Gruen TA, McNeice GM, Amstutz HC (1979) "Modes of failures" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17-27
    • (1979) Clin Orthop , vol.141 , pp. 17-27
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 6
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty. An end-result study using a new method of result evaluation
    • Harris WH (1968) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg [Am] 51:737-755
    • (1968) J Bone Joint Surg [Am] , vol.51 , pp. 737-755
    • Harris, W.H.1
  • 7
    • 0019277855 scopus 로고
    • The development of a submissive health indicator
    • Hunt SM, McEwen J (1980) The development of a submissive health indicator. Soc Health Illness 2:231-246
    • (1980) Soc Health Illness , vol.2 , pp. 231-246
    • Hunt, S.M.1    McEwen, J.2
  • 8
    • 0025270925 scopus 로고
    • Clinical and radiographic evaluation of total hip replacement: A standard system of terminology for reporting results
    • Johnston RC, Fitzgerald RH, Harris WH, Poss R. Müller ME, Sledge CB (1990) Clinical and radiographic evaluation of total hip replacement: a standard system of terminology for reporting results. J Bone Joint Surg [Am] 72:161-168
    • (1990) J Bone Joint Surg [Am] , vol.72 , pp. 161-168
    • Johnston, R.C.1    Fitzgerald, R.H.2    Harris, W.H.3    Poss, R.4    Müller, M.E.5    Sledge, C.B.6
  • 9
    • 0027409719 scopus 로고
    • Dual-energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants
    • Kilgus DJ, Shimaoka EE, Tipton JS, Eberle RW (1993) Dual-energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. J Bone Joint Surg [Br] 75:279-287
    • (1993) J Bone Joint Surg [Br] , vol.75 , pp. 279-287
    • Kilgus, D.J.1    Shimaoka, E.E.2    Tipton, J.S.3    Eberle, R.W.4
  • 10
    • 0026464523 scopus 로고
    • Determination of bone mineral density by dual X-ray absorptiometry in patients with uncemented total hip arthroplasty
    • Kiratli BJ, Heiner JP, McBeath AA, Wilson MA (1992) Determination of bone mineral density by dual X-ray absorptiometry in patients with uncemented total hip arthroplasty. J Orthop Res 10:836-844
    • (1992) J Orthop Res , vol.10 , pp. 836-844
    • Kiratli, B.J.1    Heiner, J.P.2    McBeath, A.A.3    Wilson, M.A.4
  • 11
    • 0029758076 scopus 로고    scopus 로고
    • Evaluation of periprosthetic bone using dual-energy X-ray absorptiometry: Precision of the method and effect of operation on bone mineral density
    • Kroger H, Miettinen H, Arnala I, Koski E, Rushton N, Suomalainen O (1996) Evaluation of periprosthetic bone using dual-energy X-ray absorptiometry: precision of the method and effect of operation on bone mineral density. J Bone Miner Res 11:1526-1530
    • (1996) J Bone Miner Res , vol.11 , pp. 1526-1530
    • Kroger, H.1    Miettinen, H.2    Arnala, I.3    Koski, E.4    Rushton, N.5    Suomalainen, O.6
  • 14
    • 0031544166 scopus 로고    scopus 로고
    • Effect of a stemless femoral implant for total hip arthroplasty on the bone mineral density of the proximal femur. A prospective longitudinal study
    • Munting E, Smitz P, Van Sante N, Nagant de Deuxchaisnes C, Vincent A, Devogelaer J (1997) Effect of a stemless femoral implant for total hip arthroplasty on the bone mineral density of the proximal femur. A prospective longitudinal study. J Arthroplasly 12:373-379
    • (1997) J Arthroplasly , vol.12 , pp. 373-379
    • Munting, E.1    Smitz, P.2    Van Sante, N.3    Nagant De Deuxchaisnes, C.4    Vincent, A.5    Devogelaer, J.6
  • 15
    • 0029129207 scopus 로고
    • Bone loss from the proximal femur after arthroplasty with an isoelastic femoral stem
    • Niinimäki TJ, Jalovaara PAK (1995) Bone loss from the proximal femur after arthroplasty with an isoelastic femoral stem. Acta Orthop Scand 66:347-351
    • (1995) Acta Orthop Scand , vol.66 , pp. 347-351
    • Niinimäki, T.J.1    Jalovaara, P.A.K.2
  • 16
    • 0017837076 scopus 로고
    • Proximal strain distribution in the loaded femur
    • Oh I, Harris WH (1978) Proximal strain distribution in the loaded femur. J Bone Joint Surg [Am] 60:75-83
    • (1978) J Bone Joint Surg [Am] , vol.60 , pp. 75-83
    • Oh, I.1    Harris, W.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.