메뉴 건너뛰기




Volumn 20, Issue 2, 2007, Pages 114-121

Comparison of color LCD and medical-grade monochrome LCD displays in diagnostic radiology

Author keywords

Digital imaging; Displays; Image quality; Liquid crystal display; Luminance; Medical imaging; Monitor; PACS

Indexed keywords

LUMBAR SPINE RADIOGRAPHS; PACS; STANDARD COLOR DISPLAYS; VISUAL GRADING ANALYSIS (VGA);

EID: 34249025465     PISSN: 08971889     EISSN: 1618727X     Source Type: Journal    
DOI: 10.1007/s10278-007-9028-5     Document Type: Article
Times cited : (39)

References (20)
  • 1
    • 0031202292 scopus 로고    scopus 로고
    • Variation of monitor luminance on radiologist productivity in the interpretation of skeletal radiographs using a picture archiving and communication system
    • Reiner B, Siegel E, Hooper F, Ghebrekidan H, Warner J, Briscoe B, Protopapas Z, Pomerantz S: Variation of monitor luminance on radiologist productivity in the interpretation of skeletal radiographs using a picture archiving and communication system. J Digit Imaging 10:176, 1997
    • (1997) J Digit Imaging , vol.10 , pp. 176
    • Reiner, B.1    Siegel, E.2    Hooper, F.3    Ghebrekidan, H.4    Warner, J.5    Briscoe, B.6    Protopapas, Z.7    Pomerantz, S.8
  • 2
    • 13844275610 scopus 로고    scopus 로고
    • Use of a human visual system model to predict observer performance with CRT vs LCD display of images
    • Krupinski EA, Johnson J, Roehrig H, Nafziger J, Fan J, Lubin J: Use of a human visual system model to predict observer performance with CRT vs LCD display of images. J Digit Imaging 17:258-263, 2004
    • (2004) J Digit Imaging , vol.17 , pp. 258-263
    • Krupinski, E.A.1    Johnson, J.2    Roehrig, H.3    Nafziger, J.4    Fan, J.5    Lubin, J.6
  • 3
    • 15044349827 scopus 로고    scopus 로고
    • SCAR R&D Symposium 2003: Comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease
    • Langer S, Bartholmai B, Fetterly K, Harmsen S, Ryan W, Erickson B, Andriole K, Carrino J: SCAR R&D Symposium 2003: comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease. J Digit Imaging 17:149-157, 2004
    • (2004) J Digit Imaging , vol.17 , pp. 149-157
    • Langer, S.1    Bartholmai, B.2    Fetterly, K.3    Harmsen, S.4    Ryan, W.5    Erickson, B.6    Andriole, K.7    Carrino, J.8
  • 4
    • 0003892096 scopus 로고    scopus 로고
    • Commission of the European Communities: EUR 16260, Office for Official Publications of the European Communities, Luxembourg
    • Commission of the European Communities: European guidelines on quality criteria for diagnostic radiographic images, EUR 16260, Office for Official Publications of the European Communities, Luxembourg, 1996
    • (1996) European Guidelines on Quality Criteria for Diagnostic Radiographic Images
  • 5
    • 0141618366 scopus 로고    scopus 로고
    • Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography
    • Pärtan G, Mayrhofer R, Urban M, Wassipaul M, Pichler L, Hruby W: Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography. Eur Radiol 13:2397-2401, 2003
    • (2003) Eur Radiol , vol.13 , pp. 2397-2401
    • Pärtan, G.1    Mayrhofer, R.2    Urban, M.3    Wassipaul, M.4    Pichler, L.5    Hruby, W.6
  • 6
    • 8744285664 scopus 로고    scopus 로고
    • Comparison of computer display monitors for computed radiography diagnostic application in a radiology PACS
    • Sim L, Manthey P, Esdaile P, Benson M: Comparison of computer display monitors for computed radiography diagnostic application in a radiology PACS. Australas Phys Eng Sci Med 27:148-150, 2004
    • (2004) Australas Phys Eng Sci Med , vol.27 , pp. 148-150
    • Sim, L.1    Manthey, P.2    Esdaile, P.3    Benson, M.4
  • 7
    • 27744586806 scopus 로고    scopus 로고
    • Personal computer versus workstation display: Observer performance in detection of wrist fractures on digital radiographs
    • Doyle AJ, Le Fevre J, Anderson GD: Personal computer versus workstation display: observer performance in detection of wrist fractures on digital radiographs. Radiology 237:872-877, 2005
    • (2005) Radiology , vol.237 , pp. 872-877
    • Doyle, A.J.1    Le Fevre, J.2    Anderson, G.D.3
  • 8
    • 0035984956 scopus 로고    scopus 로고
    • Personal computer-based PACS display system: Comparison with a dedicated PACS workstation for review of computed radiographic images in rheumatoid arthritis
    • Doyle AJ, Gunn ML, Gamble GD, Zhang M: Personal computer-based PACS display system: comparison with a dedicated PACS workstation for review of computed radiographic images in rheumatoid arthritis. Acad Radiol 9:646-653, 2002
    • (2002) Acad Radiol , vol.9 , pp. 646-653
    • Doyle, A.J.1    Gunn, M.L.2    Gamble, G.D.3    Zhang, M.4
  • 10
    • 4143115534 scopus 로고    scopus 로고
    • Effect of monitor luminance and ambient light on observer performance in soft-copy reading of digital chest radiographs
    • Goo JM, Choi JY, Im JG, Lee HJ, Chung MJ, Han D, Park SH, Kim JH, Nam SH: Effect of monitor luminance and ambient light on observer performance in soft-copy reading of digital chest radiographs. Radiology 232:762-766, 2004
    • (2004) Radiology , vol.232 , pp. 762-766
    • Goo, J.M.1    Choi, J.Y.2    Im, J.G.3    Lee, H.J.4    Chung, M.J.5    Han, D.6    Park, S.H.7    Kim, J.H.8    Nam, S.H.9
  • 12
    • 0033277470 scopus 로고    scopus 로고
    • Influence of film and monitor display luminance on observer performance and visual search
    • Krupinski E, Roehrig H, Furukawa T: Influence of film and monitor display luminance on observer performance and visual search. Acad Radiol 6:411-418, 1999
    • (1999) Acad Radiol , vol.6 , pp. 411-418
    • Krupinski, E.1    Roehrig, H.2    Furukawa, T.3
  • 13
    • 0035984953 scopus 로고    scopus 로고
    • Pulmonary nodule detection and visual search: P45 and P104 monochrome versus color monitor displays
    • Krupinski EA, Roehrig H: Pulmonary nodule detection and visual search: P45 and P104 monochrome versus color monitor displays. Acad Radiol 9:638-645, 2002
    • (2002) Acad Radiol , vol.9 , pp. 638-645
    • Krupinski, E.A.1    Roehrig, H.2
  • 14
    • 0035560182 scopus 로고    scopus 로고
    • Image quality vs radiation dose for a flat-panel amorphous silicon detector: A phantom study
    • Geijer H, Beckman K-W, Andersson T, Persliden J: Image quality vs radiation dose for a flat-panel amorphous silicon detector: a phantom study. Eur Radiol 11:1704-1709, 2001
    • (2001) Eur Radiol , vol.11 , pp. 1704-1709
    • Geijer, H.1    Beckman, K.-W.2    Andersson, T.3    Persliden, J.4
  • 15
    • 2942702158 scopus 로고    scopus 로고
    • Effect of room illuminance on monitor black level luminance and monitor calibration
    • Chakrabarti K, Kaczmarek RV, Thomas JA, Romanyukha A: Effect of room illuminance on monitor black level luminance and monitor calibration. J Digit Imaging 16:350-355, 2003
    • (2003) J Digit Imaging , vol.16 , pp. 350-355
    • Chakrabarti, K.1    Kaczmarek, R.V.2    Thomas, J.A.3    Romanyukha, A.4
  • 16
    • 0037231261 scopus 로고    scopus 로고
    • Influence of monitor luminance change on observer performance for detection of abnormalities depicted on chest radiographs
    • Ikeda M, Ishigaki T, Shimamoto K, Kodera Y, Koyama S, Usami H, Kato K: Influence of monitor luminance change on observer performance for detection of abnormalities depicted on chest radiographs. Invest Radiol 38:57-63, 2003
    • (2003) Invest Radiol , vol.38 , pp. 57-63
    • Ikeda, M.1    Ishigaki, T.2    Shimamoto, K.3    Kodera, Y.4    Koyama, S.5    Usami, H.6    Kato, K.7
  • 17
    • 0346906978 scopus 로고    scopus 로고
    • Proposal of a quality-index or metric for soft copy display systems: Contrast sensitivity study
    • Wang J, Compton K, Peng Q: Proposal of a quality-index or metric for soft copy display systems: contrast sensitivity study. J Digit Imaging 16:185-202, 2003
    • (2003) J Digit Imaging , vol.16 , pp. 185-202
    • Wang, J.1    Compton, K.2    Peng, Q.3
  • 18
    • 0038418372 scopus 로고    scopus 로고
    • Resolution requirements for monitor viewing of digital flat-panel detector radiographs: A contrast detail analysis
    • Peer S, Giacomuzzi SM, Peer R, Gassner E, Steingruber I, Jaschke W: Resolution requirements for monitor viewing of digital flat-panel detector radiographs: a contrast detail analysis. Eur Radiol 13:413-417, 2003
    • (2003) Eur Radiol , vol.13 , pp. 413-417
    • Peer, S.1    Giacomuzzi, S.M.2    Peer, R.3    Gassner, E.4    Steingruber, I.5    Jaschke, W.6
  • 19
    • 0032588496 scopus 로고    scopus 로고
    • Optimization of a contrast-detail-based method for electronic image display quality evaluation
    • Hangiandreou NJ, Fetterly KA, Felmlee JP: Optimization of a contrast-detail-based method for electronic image display quality evaluation. J Digit Imaging 12:60-67, 1999
    • (1999) J Digit Imaging , vol.12 , pp. 60-67
    • Hangiandreou, N.J.1    Fetterly, K.A.2    Felmlee, J.P.3
  • 20
    • 0032664605 scopus 로고    scopus 로고
    • The sensitivity of visual targets for display quality assessment
    • Van Metter R, Zhao BS, Kohm K: The sensitivity of visual targets for display quality assessment. Proc SPIE 3658:254-268, 1999
    • (1999) Proc SPIE , vol.3658 , pp. 254-268
    • Van Metter, R.1    Zhao, B.S.2    Kohm, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.