메뉴 건너뛰기




Volumn 18, Issue 6, 2007, Pages 813-814

Percutaneous Removal of a Knotted Pulmonary Artery Catheter Using Sheaths and Parallel Crossing Wires

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ANGIOGRAPHY; CASE REPORT; CATHETER REMOVAL; CONGESTIVE HEART FAILURE; CORONARY ARTERY BYPASS SURGERY; CORONARY ARTERY DISEASE; ECHOGRAPHY; FALSE ANEURYSM; FLUOROSCOPY; HEART ARREST; HEART ARRHYTHMIA; HEART INFARCTION; HEMATOTHORAX; HUMAN; INTENSIVE CARE UNIT; LETTER; MALE; PNEUMOTHORAX; PRIORITY JOURNAL; PULMONARY ARTERY CATHETER; RESUSCITATION; THORAX RADIOGRAPHY;

EID: 34249012783     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvir.2007.03.016     Document Type: Letter
Times cited : (4)

References (6)
  • 1
    • 0036017488 scopus 로고    scopus 로고
    • Salvage of a misplaced hickman catheter: a new endovascular technique
    • Owens C., Mercurio S., and Conneely M. Salvage of a misplaced hickman catheter: a new endovascular technique. J Vasc Intervent Radiol 13 (2002) 657-658
    • (2002) J Vasc Intervent Radiol , vol.13 , pp. 657-658
    • Owens, C.1    Mercurio, S.2    Conneely, M.3
  • 2
    • 0032031971 scopus 로고    scopus 로고
    • Nonsurgical extraction of intracardiac double-knotted pulmonary artery catheter
    • Ismail K.M., Deckmyn T.J., Vandermeersch E., and Stockx L. Nonsurgical extraction of intracardiac double-knotted pulmonary artery catheter. J Clin Anesth 10 (1998) 160-162
    • (1998) J Clin Anesth , vol.10 , pp. 160-162
    • Ismail, K.M.1    Deckmyn, T.J.2    Vandermeersch, E.3    Stockx, L.4
  • 4
    • 0019792917 scopus 로고
    • The knotted Swan-Ganz catheter: new solution to a vexing problem
    • Dach J.L., Galbut D.L., and LePage J.R. The knotted Swan-Ganz catheter: new solution to a vexing problem. AJR Am J Roentgenol 137 (1981) 1274-1275
    • (1981) AJR Am J Roentgenol , vol.137 , pp. 1274-1275
    • Dach, J.L.1    Galbut, D.L.2    LePage, J.R.3
  • 5
    • 0033917152 scopus 로고    scopus 로고
    • Percutaneous untying of a knot in a retained Swan-Ganz catheter
    • Bhatti W.A., Sinha S., and Rowlands P. Percutaneous untying of a knot in a retained Swan-Ganz catheter. Cardiovasc Intervent Radiol 23 (2000) 224-225
    • (2000) Cardiovasc Intervent Radiol , vol.23 , pp. 224-225
    • Bhatti, W.A.1    Sinha, S.2    Rowlands, P.3
  • 6
    • 0031983378 scopus 로고    scopus 로고
    • Successful nonsurgical removal of a knotted and entrapped pulmonary artery catheter
    • Mehta N., Lochab S.S., Tempe D.K., Trehan V., and Nigam M. Successful nonsurgical removal of a knotted and entrapped pulmonary artery catheter. Cathet Cardiovasc Diagn 43 (1998) 87-89
    • (1998) Cathet Cardiovasc Diagn , vol.43 , pp. 87-89
    • Mehta, N.1    Lochab, S.S.2    Tempe, D.K.3    Trehan, V.4    Nigam, M.5