메뉴 건너뛰기




Volumn 10, Issue 2, 1998, Pages 160-162

Nonsurgical extraction of intracardiac double-knotted pulmonary artery catheter

Author keywords

Catheter, pulmonary artery; Complications, catheter knotting

Indexed keywords

ABDOMINAL AORTA ANEURYSM; AGED; ANEURYSM RUPTURE; ANEURYSM SURGERY; ARTERY CATHETERIZATION; ARTICLE; CASE REPORT; EMERGENCY SURGERY; HEART INJURY; HUMAN; LAPAROTOMY; MALE; PRIORITY JOURNAL; PULMONARY ARTERY; THORAX RADIOGRAPHY;

EID: 0032031971     PISSN: 09528180     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0952-8180(97)00261-4     Document Type: Article
Times cited : (11)

References (12)
  • 1
    • 0014964972 scopus 로고
    • Catheterization of the heart in man with use of a flow-directed ballon-tipped catheter
    • Swan H, Ganz W, Forrester J, et al: Catheterization of the heart in man with use of a flow-directed ballon-tipped catheter. N Engl J Med 1970;283:447-51.
    • (1970) N Engl J Med , vol.283 , pp. 447-451
    • Swan, H.1    Ganz, W.2    Forrester, J.3
  • 3
    • 0016401628 scopus 로고
    • Pulmonary complications of the flow-directed ballon-tipped catheter
    • Foote GA, Schabel SI, Hodges M: Pulmonary complications of the flow-directed ballon-tipped catheter. N Engl J Med 1974;290: 927-31.
    • (1974) N Engl J Med , vol.290 , pp. 927-931
    • Foote, G.A.1    Schabel, S.I.2    Hodges, M.3
  • 4
    • 0020556658 scopus 로고
    • Pathophysiology of rupture of the pulmonary artery by pulmonary artery balloon-tipped catheters
    • Hardy JF, Morissette M, Taillefer J, Vauclair R: Pathophysiology of rupture of the pulmonary artery by pulmonary artery balloon-tipped catheters. Anesth Analg 1983;62:925-30.
    • (1983) Anesth Analg , vol.62 , pp. 925-930
    • Hardy, J.F.1    Morissette, M.2    Taillefer, J.3    Vauclair, R.4
  • 5
    • 0018729674 scopus 로고
    • Right bundle-branch block and complete heart block caused by the Swan-Ganz catheter
    • Thomson IR, Dalton BC, Lappas DG, Lowenstein F: Right bundle-branch block and complete heart block caused by the Swan-Ganz catheter. Anesthesiology 1979;51:359-62.
    • (1979) Anesthesiology , vol.51 , pp. 359-362
    • Thomson, I.R.1    Dalton, B.C.2    Lappas, D.G.3    Lowenstein, F.4
  • 8
    • 0023580290 scopus 로고
    • The value of Swan-Ganz catheterization and volume loading in preventing renal failure in patients undergoing abdominal aneurysmectomy
    • Hesdorffer CS, Milne JF, Meyers AM, Clinton C, Botha R: The value of Swan-Ganz catheterization and volume loading in preventing renal failure in patients undergoing abdominal aneurysmectomy. Clin Nephrol 1987;28:272-6.
    • (1987) Clin Nephrol , vol.28 , pp. 272-276
    • Hesdorffer, C.S.1    Milne, J.F.2    Meyers, A.M.3    Clinton, C.4    Botha, R.5
  • 9
    • 33847450285 scopus 로고
    • Practice guidelines for pulmonary artery catheterization. A report by the American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization
    • Practice guidelines for pulmonary artery catheterization. A report by the American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization. Anesthesiology 1993;78:880-94.
    • (1993) Anesthesiology , vol.78 , pp. 880-894
  • 12
    • 0027452293 scopus 로고
    • Transesophageal echocardiography-guided pulmonary artery catheter placement
    • Turnage WS, Fontanet H: Transesophageal echocardiography-guided pulmonary artery catheter placement. Anesth Analg 1993; 77:858-9.
    • (1993) Anesth Analg , vol.77 , pp. 858-859
    • Turnage, W.S.1    Fontanet, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.