메뉴 건너뛰기




Volumn 41, Issue SUPPL. 1, 2006, Pages

Thermoluminescent materials for medical applications: LiF:Mg,Ti and LiF:Mg,Cu,P

Author keywords

[No Author keywords available]

Indexed keywords

MEDICAL APPLICATIONS; RADIOLOGY; RADIOTHERAPY; SENSITIVITY ANALYSIS; THERMOLUMINESCENCE;

EID: 34248527907     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2007.01.008     Document Type: Article
Times cited : (62)

References (19)
  • 1
    • 0023189646 scopus 로고
    • The variability of clinical thermoluminescent dosimetry systems: a multi-institutional study
    • Amols H.I., Weinhous M.S., and Reinstein L.E. The variability of clinical thermoluminescent dosimetry systems: a multi-institutional study. Med. Phys. 14 (1987) 291-295
    • (1987) Med. Phys. , vol.14 , pp. 291-295
    • Amols, H.I.1    Weinhous, M.S.2    Reinstein, L.E.3
  • 2
    • 0030958971 scopus 로고    scopus 로고
    • Dependence of LiF: Mg,Cu,P (MCP-N) glow curve structure on dopant composition and thermal treatment
    • Bilski P., Budzanowski M., and Olko P. Dependence of LiF: Mg,Cu,P (MCP-N) glow curve structure on dopant composition and thermal treatment. Radiat. Prot. Dosim. 69 (1997) 187-198
    • (1997) Radiat. Prot. Dosim. , vol.69 , pp. 187-198
    • Bilski, P.1    Budzanowski, M.2    Olko, P.3
  • 4
    • 34248544004 scopus 로고    scopus 로고
    • Clinical use of LiF:Mg,Cu,P: critical evaluation of an ultrasensitive material for thermoluminescence dosimetry
    • Duggan L. Clinical use of LiF:Mg,Cu,P: critical evaluation of an ultrasensitive material for thermoluminescence dosimetry. Med. Phys. 29 (2002) 2457
    • (2002) Med. Phys. , vol.29 , pp. 2457
    • Duggan, L.1
  • 5
    • 34248528303 scopus 로고    scopus 로고
    • A comparison of TLD dosimeters: LiFMg,Ti and LiF:Mg,Cu,P for measurement of radiation therapy dose
    • Glennie G.D. A comparison of TLD dosimeters: LiFMg,Ti and LiF:Mg,Cu,P for measurement of radiation therapy dose. Med. Phys. 30 (2003) 3262
    • (2003) Med. Phys. , vol.30 , pp. 3262
    • Glennie, G.D.1
  • 6
    • 0030759047 scopus 로고    scopus 로고
    • A comparison of the effectiveness of thermoluminescent crystals LiF: Mg,Ti and LiF:Mg,Cu,P for clinical dosimetry
    • Harris C.K., Elson R.H., Lamba M.A.S., and Foster A.E. A comparison of the effectiveness of thermoluminescent crystals LiF: Mg,Ti and LiF:Mg,Cu,P for clinical dosimetry. Med. Phys. 24 (1997) 1527-1529
    • (1997) Med. Phys. , vol.24 , pp. 1527-1529
    • Harris, C.K.1    Elson, R.H.2    Lamba, M.A.S.3    Foster, A.E.4
  • 7
    • 0019388414 scopus 로고
    • The theoretical and microdosimetric basis of thermoluminescence and applications to dosimetry
    • Horowitz Y.S. The theoretical and microdosimetric basis of thermoluminescence and applications to dosimetry. Phys. Med. Biol. 26 (1982) 765-824
    • (1982) Phys. Med. Biol. , vol.26 , pp. 765-824
    • Horowitz, Y.S.1
  • 9
    • 0035445887 scopus 로고    scopus 로고
    • Theory of thermoluminescence gamma dose response: the unified interaction Model
    • Horowitz Y.S. Theory of thermoluminescence gamma dose response: the unified interaction Model. Nucl. Instrum. Methods B 184 (2001) 68-84
    • (2001) Nucl. Instrum. Methods B , vol.184 , pp. 68-84
    • Horowitz, Y.S.1
  • 10
    • 0031658787 scopus 로고
    • The unified interaction model applied to the gamma induced supralinearity and sensitization of peaks 4 and 5 in LiF:Mg,Ti (TLD-100)
    • Horowitz Y.S., Mahajna S., Oster L., Weizman Y., Satinger D., and Yossian D. The unified interaction model applied to the gamma induced supralinearity and sensitization of peaks 4 and 5 in LiF:Mg,Ti (TLD-100). Radiat. Prot. Dosim. 78 (1988) 169-193
    • (1988) Radiat. Prot. Dosim. , vol.78 , pp. 169-193
    • Horowitz, Y.S.1    Mahajna, S.2    Oster, L.3    Weizman, Y.4    Satinger, D.5    Yossian, D.6
  • 11
    • 34248536892 scopus 로고    scopus 로고
    • Horowitz, Y.S., Olko, P., The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P, in press.
  • 12
    • 0026498079 scopus 로고
    • Uncertainty analysis of absorbed dose calculations for thermoluminescence dosimeters
    • Kirby T.H., Hanson W.F., and Johnson D.A. Uncertainty analysis of absorbed dose calculations for thermoluminescence dosimeters. Med. Phys. 19 (1992) 1427-1433
    • (1992) Med. Phys. , vol.19 , pp. 1427-1433
    • Kirby, T.H.1    Hanson, W.F.2    Johnson, D.A.3
  • 13
    • 0038986121 scopus 로고
    • Supralinearity of thermoluminescent dosimeters
    • Larsson L., and Katz R. Supralinearity of thermoluminescent dosimeters. Nucl. Instrum. Methods 138 (1976) 631-636
    • (1976) Nucl. Instrum. Methods , vol.138 , pp. 631-636
    • Larsson, L.1    Katz, R.2
  • 14
    • 34248528304 scopus 로고    scopus 로고
    • McKeever, S.W.S., Moscovitch, M., Townsend, P.D., 1995. Thermoluminescence Dosimetry Materials: Properties and Uses. Nuclear Technology Publishing.
  • 15
    • 2642668467 scopus 로고    scopus 로고
    • A study of LiF GR-200 for radiotherapy mailed dosimetry
    • Muniz J.L., and Delgado A. A study of LiF GR-200 for radiotherapy mailed dosimetry. Phys. Med. Biol. 42 (1997) 2569-2576
    • (1997) Phys. Med. Biol. , vol.42 , pp. 2569-2576
    • Muniz, J.L.1    Delgado, A.2
  • 16
    • 0003304896 scopus 로고
    • Development of a new highly sensitive LiF thermoluminescence dosimeter and its applications
    • Nakajima T., Maruyama Y., Matsuzawa T., and Koyano A. Development of a new highly sensitive LiF thermoluminescence dosimeter and its applications. Nucl. Instrum. Methods 157 (1978) 155-162
    • (1978) Nucl. Instrum. Methods , vol.157 , pp. 155-162
    • Nakajima, T.1    Maruyama, Y.2    Matsuzawa, T.3    Koyano, A.4
  • 17
    • 34248528305 scopus 로고    scopus 로고
    • Ramlo, M., Moscovitch, M., Rotunda, J.E., 2004. Reduction of residual in Harshaw TLD100H (LiF:MCP), in preparation.
  • 18
    • 0000548431 scopus 로고
    • Supralinearity of peak 5 and peak 6 in TLD-700
    • Waligorski M.P.R., and Katz R. Supralinearity of peak 5 and peak 6 in TLD-700. Nucl. Instrum. Methods 172 (1980) 463-470
    • (1980) Nucl. Instrum. Methods , vol.172 , pp. 463-470
    • Waligorski, M.P.R.1    Katz, R.2
  • 19
    • 0021245246 scopus 로고
    • A high-sensitivity LiF thermoluminescent dosimeter-LiF(Mg,Cu,P)
    • Wu D.K., Sun F.Y., and Dai H.C. A high-sensitivity LiF thermoluminescent dosimeter-LiF(Mg,Cu,P). Health Phys. 46 (1984) 1063-1067
    • (1984) Health Phys. , vol.46 , pp. 1063-1067
    • Wu, D.K.1    Sun, F.Y.2    Dai, H.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.