메뉴 건너뛰기




Volumn 24, Issue 9, 1997, Pages 1527-1529

A comparison of the effectiveness of thermoluminescent crystals LiF:Mg,Ti, and LiF:Mg,Cu,P for clinical dosimetry

Author keywords

LiF; Radiation dosimetry; Thermoluminescence

Indexed keywords

CRYSTALS; DOSIMETRY; THERMOLUMINESCENCE;

EID: 0030759047     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598042     Document Type: Article
Times cited : (21)

References (8)
  • 1
    • 0027268426 scopus 로고
    • LiF:Mg, Ti versus LiF:Mg, Cu, P: The competition heats up
    • Y. S. Horowitz, "LiF:Mg, Ti versus LiF:Mg, Cu, P: the competition heats up," Radiat. Prot. Dosim. 47, 135-141 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , pp. 135-141
    • Horowitz, Y.S.1
  • 2
    • 0027240269 scopus 로고
    • Preparation and characteristics of LiF:Mg, Cu, P thermoluminescent material
    • Z. Zha, S. Wang, W. Shen, J. Zhu, and G. Cai, "Preparation and characteristics of LiF:Mg, Cu, P thermoluminescent material," Radiat. Prot. Dosim. 47, 111-118 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , pp. 111-118
    • Zha, Z.1    Wang, S.2    Shen, W.3    Zhu, J.4    Cai, G.5
  • 3
    • 0028712549 scopus 로고
    • Thermoluminescence dosimetry and its applications in medicine - Part 1: Physics, materials and equipment
    • T. Kron, "Thermoluminescence dosimetry and its applications in medicine - Part 1: Physics, materials and equipment," Sciences in Med 17, 175-199 (1994)
    • (1994) Sciences in Med , vol.17 , pp. 175-199
    • Kron, T.1
  • 5
    • 0022586754 scopus 로고
    • Newly developed highly sensitive LiF:(Mg, Cu, P) TL chips with high S/N ratio
    • S. Wang, G Chen, F Wu, Y. Li, Z. Zha, and J Zhu, "Newly developed highly sensitive LiF:(Mg, Cu, P) TL chips with high S/N ratio," Radiat. Prot. Dosim. 14, 223-227 (1986).
    • (1986) Radiat. Prot. Dosim. , vol.14 , pp. 223-227
    • Wang, S.1    Chen, G.2    Wu, F.3    Li, Y.4    Zha, Z.5    Zhu, J.6
  • 6
    • 0022919646 scopus 로고
    • Measurement of extremely low level dose with LiF:(Mg, Cu, P)
    • Z. Zha, S. Wang, F. Wu, G. Chen, Y. Li, and J. Zhu, "Measurement of extremely low level dose with LiF:(Mg, Cu, P)," Radiat. Prot. Dosim. 17, 415 (1986)
    • (1986) Radiat. Prot. Dosim. , vol.17 , pp. 415
    • Zha, Z.1    Wang, S.2    Wu, F.3    Chen, G.4    Li, Y.5    Zhu, J.6
  • 7
    • 0018877105 scopus 로고
    • Equivalent half-value thicknesses and mean energies of filtered X-ray bremsstrahlung spectra
    • W. W. Seelentag and W. Panzer, "Equivalent half-value thicknesses and mean energies of filtered X-ray bremsstrahlung spectra," Br. J. Radiol. 53, 236-240 (1980).
    • (1980) Br. J. Radiol. , vol.53 , pp. 236-240
    • Seelentag, W.W.1    Panzer, W.2
  • 8
    • 3943054109 scopus 로고
    • Thermoluminescent radiation dosimetry
    • edited by Y. S. Horowitz CRC, Boca Raton, Chap. 2
    • Y. S. Horowitz, "Thermoluminescent radiation dosimetry," in Thermoluminescence and Thermoluminescent Dosimetry, edited by Y. S. Horowitz (CRC, Boca Raton, 1984), Chap. 2.
    • (1984) Thermoluminescence and Thermoluminescent Dosimetry
    • Horowitz, Y.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.