메뉴 건너뛰기




Volumn 32, Issue 11, 2007, Pages 1220-1226

Biomechanical comparison of instrumented and uninstrumented multilevel cervical discectomy versus corpectomy

Author keywords

Biomechanics; Cervical spondylosis; Corpectomy; Discectomy

Indexed keywords

ARTICLE; BIOMECHANICS; BONE GRAFT; BONE PLATE; BONE SCREW; CADAVER; CERVICAL SPINE; CONTROLLED STUDY; CORPECTOMY; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; INTERVERTEBRAL DISKECTOMY; INTRAMEDULLARY NAILING; LOADING TEST; ORTHOPEDIC EQUIPMENT; PRIORITY JOURNAL; RANGE OF MOTION; SPINE MOBILITY; SPINE SURGERY; STEREOPHOTOGRAMMETRY;

EID: 34248362792     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/01.brs.0000270104.95045.24     Document Type: Article
Times cited : (18)

References (26)
  • 1
    • 0034663024 scopus 로고    scopus 로고
    • Three- and four-level anterior cervical discectomy and fusion with plate fixation: A prospective study
    • Bolesta MJ, Rechtine GR, Chrin AM. Three- and four-level anterior cervical discectomy and fusion with plate fixation: a prospective study. Spine 2000;25:2040-4.
    • (2000) Spine , vol.25 , pp. 2040-2044
    • Bolesta, M.J.1    Rechtine, G.R.2    Chrin, A.M.3
  • 2
    • 0031879359 scopus 로고    scopus 로고
    • Anterior cervical corpectomy for cervical spondylotic myelopathy
    • Fessler RG, Steck JC, Giovanini MA. Anterior cervical corpectomy for cervical spondylotic myelopathy. Neurosurgery 1998;43:257-65.
    • (1998) Neurosurgery , vol.43 , pp. 257-265
    • Fessler, R.G.1    Steck, J.C.2    Giovanini, M.A.3
  • 3
    • 0036118273 scopus 로고    scopus 로고
    • Cervical spinal stenosis: Outcome after anterior corpectomy, allograft reconstruction, and instrumentation
    • Mayr MT, Subach BR, Comey CH, et al. Cervical spinal stenosis: outcome after anterior corpectomy, allograft reconstruction, and instrumentation. J Neurosurg 2002;96:10-6.
    • (2002) J Neurosurg , vol.96 , pp. 10-16
    • Mayr, M.T.1    Subach, B.R.2    Comey, C.H.3
  • 4
    • 0033959031 scopus 로고    scopus 로고
    • Increased fusion rates with cervical plating for two-level anterior cervical discectomy and fusion
    • Wang JC, McDonough PW, Endow KK, et al. Increased fusion rates with cervical plating for two-level anterior cervical discectomy and fusion. Spine 2000;25:41-5.
    • (2000) Spine , vol.25 , pp. 41-45
    • Wang, J.C.1    McDonough, P.W.2    Endow, K.K.3
  • 5
    • 0035868874 scopus 로고    scopus 로고
    • Increased fusion rates with cervical plating for three-level anterior cervical discectomy and fusion
    • Wang JC, McDonough PW, Kanim LE, et al. Increased fusion rates with cervical plating for three-level anterior cervical discectomy and fusion. Spine 2001;26:643-6.
    • (2001) Spine , vol.26 , pp. 643-646
    • Wang, J.C.1    McDonough, P.W.2    Kanim, L.E.3
  • 6
    • 0344222223 scopus 로고    scopus 로고
    • Three-level anterior cervical discectomy and fusion: Radiographic and clinical results
    • Emery SE, Fisher JR, Bohlman HH. Three-level anterior cervical discectomy and fusion: radiographic and clinical results. Spine 1997;22:2622-4.
    • (1997) Spine , vol.22 , pp. 2622-2624
    • Emery, S.E.1    Fisher, J.R.2    Bohlman, H.H.3
  • 7
    • 0031725307 scopus 로고    scopus 로고
    • Early failure of long segment anterior cervical plate fixation
    • Vaccaro AR, Falatyn SP, Scuderi GJ, et al. Early failure of long segment anterior cervical plate fixation. J Spinal Disord 1998;11:410-5.
    • (1998) J Spinal Disord , vol.11 , pp. 410-415
    • Vaccaro, A.R.1    Falatyn, S.P.2    Scuderi, G.J.3
  • 8
    • 0037439134 scopus 로고    scopus 로고
    • Early reconstruction failures after multilevel cervical corpectomy
    • Sasso RC, Ruggiero RA Jr, Reilly TM, et al. Early reconstruction failures after multilevel cervical corpectomy. Spine 2003;28:140-2.
    • (2003) Spine , vol.28 , pp. 140-142
    • Sasso, R.C.1    Ruggiero Jr, R.A.2    Reilly, T.M.3
  • 9
    • 0029614779 scopus 로고
    • One-stage anterior cervical decompression and posterior stabilization: A study of one hundred patients with a minimum of two years of follow-up
    • McAfee PC, Bohlman HH, Ducker TB, et al. One-stage anterior cervical decompression and posterior stabilization: a study of one hundred patients with a minimum of two years of follow-up. J Bone Joint Surg Am 1995;77:1791-800.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1791-1800
    • McAfee, P.C.1    Bohlman, H.H.2    Ducker, T.B.3
  • 10
    • 0031059878 scopus 로고    scopus 로고
    • Rigid internal fixation with lateral mass plates in multilevel anterior and posterior reconstruction of the cervical spine
    • Swank ML, Sutterlin CE III, Bossons CR, et al. Rigid internal fixation with lateral mass plates in multilevel anterior and posterior reconstruction of the cervical spine. Spine 1997;22:274-82.
    • (1997) Spine , vol.22 , pp. 274-282
    • Swank, M.L.1    Sutterlin III, C.E.2    Bossons, C.R.3
  • 11
    • 0038205969 scopus 로고    scopus 로고
    • Biomechanical analysis of multilevel cervical corpectomy and plate constructs
    • Porter RW, Crawford NR, Chamberlain RH, et al. Biomechanical analysis of multilevel cervical corpectomy and plate constructs. J Neurosurg 2003;99:98-103.
    • (2003) J Neurosurg , vol.99 , pp. 98-103
    • Porter, R.W.1    Crawford, N.R.2    Chamberlain, R.H.3
  • 12
    • 0029096617 scopus 로고
    • An apparatus for applying pure nonconstraining moments to spine segments in vitro
    • Crawford NR, Brantley AG, Dickman CA, et al. An apparatus for applying pure nonconstraining moments to spine segments in vitro. Spine 1995;20:2097-100.
    • (1995) Spine , vol.20 , pp. 2097-2100
    • Crawford, N.R.1    Brantley, A.G.2    Dickman, C.A.3
  • 13
    • 1842682780 scopus 로고    scopus 로고
    • Enhancement of stability following anterior cervical corpectomy: A biomechanical study
    • Singh K, Vaccaro AR, Kim J, et al. Enhancement of stability following anterior cervical corpectomy: a biomechanical study. Spine 2004;29:845-9.
    • (2004) Spine , vol.29 , pp. 845-849
    • Singh, K.1    Vaccaro, A.R.2    Kim, J.3
  • 14
    • 0031409653 scopus 로고    scopus 로고
    • Biomechanical evaluation of posterior cervical stabilization after a wide laminectomy
    • Grubb MR, Currier BL, Stone J, et al. Biomechanical evaluation of posterior cervical stabilization after a wide laminectomy. Spine 1997;22:1948-54.
    • (1997) Spine , vol.22 , pp. 1948-1954
    • Grubb, M.R.1    Currier, B.L.2    Stone, J.3
  • 15
    • 0033998138 scopus 로고    scopus 로고
    • Anterior cervical plating reverses load transfer through multilevel strut-grafts
    • DiAngelo DJ, Foley KT, Vossel KA, et al. Anterior cervical plating reverses load transfer through multilevel strut-grafts. Spine 2000;25:783-95.
    • (2000) Spine , vol.25 , pp. 783-795
    • DiAngelo, D.J.1    Foley, K.T.2    Vossel, K.A.3
  • 16
    • 0142056035 scopus 로고    scopus 로고
    • Biomechanical comparison of cervical spine reconstructive techniques after a multilevel corpectomy of the cervical spine
    • Singh K, Vaccaro AR, Kim J, et al. Biomechanical comparison of cervical spine reconstructive techniques after a multilevel corpectomy of the cervical spine. Spine 2003;28:2352-8.
    • (2003) Spine , vol.28 , pp. 2352-2358
    • Singh, K.1    Vaccaro, A.R.2    Kim, J.3
  • 17
    • 0022354031 scopus 로고
    • Biomechanical time-tolerance of fresh cadaveric human spine specimens
    • Panjabi MM, Krag M, Summers D, et al. Biomechanical time-tolerance of fresh cadaveric human spine specimens. J Orthop Res 1985;3:292-300.
    • (1985) J Orthop Res , vol.3 , pp. 292-300
    • Panjabi, M.M.1    Krag, M.2    Summers, D.3
  • 18
    • 84924638714 scopus 로고
    • The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion
    • Smith GW, Robinson RA. The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg Am 1958;40:607-24.
    • (1958) J Bone Joint Surg Am , vol.40 , pp. 607-624
    • Smith, G.W.1    Robinson, R.A.2
  • 19
    • 0032533960 scopus 로고    scopus 로고
    • Four-level cervical corpectomy
    • Saunders RL, Pikus HJ, Ball P. Four-level cervical corpectomy. Spine 1998;23:2455-61.
    • (1998) Spine , vol.23 , pp. 2455-2461
    • Saunders, R.L.1    Pikus, H.J.2    Ball, P.3
  • 20
    • 0026029275 scopus 로고
    • Posterior stabilization of the cervical spine with hook plates
    • Jeanneret B, Magerl F, Ward EH, et al. Posterior stabilization of the cervical spine with hook plates. Spine 1991;16(suppl):56-63.
    • (1991) Spine , vol.16 , Issue.SUPPL. , pp. 56-63
    • Jeanneret, B.1    Magerl, F.2    Ward, E.H.3
  • 21
    • 0023723917 scopus 로고
    • Biomechanical evaluation of spinal fixation devices: I. A conceptual framework
    • Panjabi MM. Biomechanical evaluation of spinal fixation devices: I. A conceptual framework. Spine 1988;13:1129-34.
    • (1988) Spine , vol.13 , pp. 1129-1134
    • Panjabi, M.M.1
  • 22
    • 0030996697 scopus 로고    scopus 로고
    • Construction of local vertebral coordinate systems using a digitizing probe [Technical note]
    • Crawford NR, Dickman CA. Construction of local vertebral coordinate systems using a digitizing probe [Technical note]. Spine 1997;22:559-63.
    • (1997) Spine , vol.22 , pp. 559-563
    • Crawford, N.R.1    Dickman, C.A.2
  • 24
    • 0031726313 scopus 로고    scopus 로고
    • The spinal lax zone and neutral zone: Measurement techniques and parameter comparisons
    • Crawford NR, Peles JD, Dickman CA. The spinal lax zone and neutral zone: measurement techniques and parameter comparisons. J Spinal Disord 1998;11:416-29.
    • (1998) J Spinal Disord , vol.11 , pp. 416-429
    • Crawford, N.R.1    Peles, J.D.2    Dickman, C.A.3
  • 25
    • 0026620583 scopus 로고
    • The stabilizing system of the spine: II. Neutral zone and instability hypothesis
    • Panjabi MM. The stabilizing system of the spine: II. Neutral zone and instability hypothesis. J Spinal Disord 1992;5:390-6.
    • (1992) J Spinal Disord , vol.5 , pp. 390-396
    • Panjabi, M.M.1
  • 26
    • 0034659390 scopus 로고    scopus 로고
    • Load-carrying capacity of the human cervical spine in compression is increased under a follower load
    • Patwardhan AG, Havey RM, Ghanayem AJ, et al. Load-carrying capacity of the human cervical spine in compression is increased under a follower load. Spine 2000;25:1548-54.
    • (2000) Spine , vol.25 , pp. 1548-1554
    • Patwardhan, A.G.1    Havey, R.M.2    Ghanayem, A.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.