메뉴 건너뛰기




Volumn 57, Issue 4, 2007, Pages 639-646

Rapid quantitation of cardiovascular flow using slice-selective fourier velocity encoding with spiral readouts

Author keywords

Fourier velocity encoding; MRI flow imaging; Partial k space reconstruction; Regurgitation; Stenosis; Valvular disease

Indexed keywords

ENCODING (SYMBOLS); FOURIER TRANSFORMS; MAGNETIC RESONANCE IMAGING; SIGNAL ENCODING; VELOCITY;

EID: 34248353416     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21196     Document Type: Article
Times cited : (16)

References (30)
  • 1
    • 0029157780 scopus 로고
    • Correction of intrinsic spectral broadening errors in Doppler peak velocity measurements made with phased sector and linear array transducers
    • Winkler AJ, Wu J. Correction of intrinsic spectral broadening errors in Doppler peak velocity measurements made with phased sector and linear array transducers. Ultrasound Med Biol 1995;21:1029-1035.
    • (1995) Ultrasound Med Biol , vol.21 , pp. 1029-1035
    • Winkler, A.J.1    Wu, J.2
  • 2
    • 0030065280 scopus 로고    scopus 로고
    • Accuracy of maximum velocity estimates made using Doppler ultrasound systems
    • Hoskins PR. Accuracy of maximum velocity estimates made using Doppler ultrasound systems. Br J Radiol 1996;69:172-177.
    • (1996) Br J Radiol , vol.69 , pp. 172-177
    • Hoskins, P.R.1
  • 3
    • 0021930201 scopus 로고
    • NMR blood flow imaging using multiecho, phase contrast sequences
    • O'Donnell M. NMR blood flow imaging using multiecho, phase contrast sequences. Med Phys 1985;12:59-64.
    • (1985) Med Phys , vol.12 , pp. 59-64
    • O'Donnell, M.1
  • 4
    • 0030226419 scopus 로고    scopus 로고
    • Velocity-encoded, phase-difference cine MRI measurements of coronary artery flow: Dependence of flow accuracy on the number of cine frames
    • Clarke GD, Hundley WG, McColl RW, Eckels R, Smith D, Chaney C, Li HF, Peshock RM. Velocity-encoded, phase-difference cine MRI measurements of coronary artery flow: dependence of flow accuracy on the number of cine frames. J Magn Reson Imag 1996;6:733-742.
    • (1996) J Magn Reson Imag , vol.6 , pp. 733-742
    • Clarke, G.D.1    Hundley, W.G.2    McColl, R.W.3    Eckels, R.4    Smith, D.5    Chaney, C.6    Li, H.F.7    Peshock, R.M.8
  • 5
    • 0027564412 scopus 로고
    • Accuracy of phase-contrast flow measurements in the presence of partial-volume effects
    • Tang C, Blatter DD, Parker DL. Accuracy of phase-contrast flow measurements in the presence of partial-volume effects. J Magn Reson Imag 1993;3:377-385.
    • (1993) J Magn Reson Imag , vol.3 , pp. 377-385
    • Tang, C.1    Blatter, D.D.2    Parker, D.L.3
  • 6
    • 0031422031 scopus 로고    scopus 로고
    • Cine MR Fourier velocimetry of blood flow through cardiac valves: Comparison with Doppler echocardiography
    • Mohiaddin RH, Gatehouse PD, Henien M, Firmin DN. Cine MR Fourier velocimetry of blood flow through cardiac valves: comparison with Doppler echocardiography. J Magn Reson Imag 1997;7:657-663.
    • (1997) J Magn Reson Imag , vol.7 , pp. 657-663
    • Mohiaddin, R.H.1    Gatehouse, P.D.2    Henien, M.3    Firmin, D.N.4
  • 7
    • 0020340302 scopus 로고
    • A flow velocity zeugmatographic interface for NMR imaging in humans
    • Moran PR. A flow velocity zeugmatographic interface for NMR imaging in humans. Magn Reson Imag 1982;1:197-203.
    • (1982) Magn Reson Imag , vol.1 , pp. 197-203
    • Moran, P.R.1
  • 8
    • 0027194536 scopus 로고
    • Localized real-time velocity spectra determination
    • Hu BS, Pauly JM, Macovski A. Localized real-time velocity spectra determination. Magn Reson Med 1993;30:393-398.
    • (1993) Magn Reson Med , vol.30 , pp. 393-398
    • Hu, B.S.1    Pauly, J.M.2    Macovski, A.3
  • 12
    • 0023688956 scopus 로고
    • Fast and exact flow measurements with the fast Fourier flow technique
    • Hennig J, Mueri M, Brunner P, Friedburg H. Fast and exact flow measurements with the fast Fourier flow technique. Magn Reson Med 1988;6:369-372.
    • (1988) Magn Reson Med , vol.6 , pp. 369-372
    • Hennig, J.1    Mueri, M.2    Brunner, P.3    Friedburg, H.4
  • 13
    • 0036703398 scopus 로고    scopus 로고
    • Peak velocity determination using fast Fourier velocity encoding with minimal spatial encoding
    • Galea D, Lauzon ML, Drangova M. Peak velocity determination using fast Fourier velocity encoding with minimal spatial encoding. Med Phys 2002;29:1719-1728.
    • (2002) Med Phys , vol.29 , pp. 1719-1728
    • Galea, D.1    Lauzon, M.L.2    Drangova, M.3
  • 16
    • 0025985527 scopus 로고
    • Spoiling of transverse magnetization in steady-state sequences
    • Zur Y, Wood ML, Neuringer LJ. Spoiling of transverse magnetization in steady-state sequences. Magn Reson Med 1991;21:251-263.
    • (1991) Magn Reson Med , vol.21 , pp. 251-263
    • Zur, Y.1    Wood, M.L.2    Neuringer, L.J.3
  • 19
    • 0023781558 scopus 로고
    • Nuclear magnetic resonance signal from flowing nuclei in rapid imaging using gradient echoes
    • Gao JH, Holland SK, Gore JC. Nuclear magnetic resonance signal from flowing nuclei in rapid imaging using gradient echoes. Med Phys 1988;15:809-814.
    • (1988) Med Phys , vol.15 , pp. 809-814
    • Gao, J.H.1    Holland, S.K.2    Gore, J.C.3
  • 21
    • 0036135282 scopus 로고    scopus 로고
    • On the UNFOLD method
    • Tsao J. On the UNFOLD method. Magn Reson Med 2002;47:202-207.
    • (2002) Magn Reson Med , vol.47 , pp. 202-207
    • Tsao, J.1
  • 22
    • 0242385483 scopus 로고    scopus 로고
    • k-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003;50:1031-1042.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 25
    • 0034007629 scopus 로고    scopus 로고
    • Reduced aliasing artifacts using variable-density k-space sampling trajectories
    • Tsai CM, Nishimura DG. Reduced aliasing artifacts using variable-density k-space sampling trajectories. Magn Reson Med 2000;43:452-458.
    • (2000) Magn Reson Med , vol.43 , pp. 452-458
    • Tsai, C.M.1    Nishimura, D.G.2
  • 27
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Bornert P, Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001;46:638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Bornert, P.3    Boesiger, P.4
  • 29
    • 0000114910 scopus 로고
    • Gradient-echo shifting in fast MRI techniques (GRASE imaging) for correction of field inhomogeneity errors and chemical shift
    • Feinberg DA, Oshio K. Gradient-echo shifting in fast MRI techniques (GRASE imaging) for correction of field inhomogeneity errors and chemical shift. J Magn Reson 1992;97:177-183.
    • (1992) J Magn Reson , vol.97 , pp. 177-183
    • Feinberg, D.A.1    Oshio, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.