메뉴 건너뛰기




Volumn 21, Issue 3, 2005, Pages 297-304

Real-time fourier velocity encoding: An in vivo evaluation

Author keywords

Blood flow; Magnetic resonance imaging; Pulmonary heart disease; Stenosis; Ultrasonics; Valves

Indexed keywords

ADULT; AORTA FLOW; ARTICLE; BLOOD FLOW VELOCITY; CONTROLLED STUDY; CORRELATION ANALYSIS; DOPPLER FLOWMETRY; FOURIER ANALYSIS; HEMODYNAMICS; HUMAN; HUMAN EXPERIMENT; IMAGE QUALITY; INFERIOR CAVA VEIN; INTERMETHOD COMPARISON; KIDNEY BLOOD FLOW; KIDNEY BLOOD VESSEL; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; WAVEFORM;

EID: 14044249517     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20266     Document Type: Article
Times cited : (21)

References (26)
  • 1
    • 0036584937 scopus 로고    scopus 로고
    • Cardiovascular flow measurement with phase-contrast MR imaging: Basic facts and implementation
    • Lotz J, Meier C, Leppert A, Galanski M. Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 2002;22:651-671.
    • (2002) Radiographics , vol.22 , pp. 651-671
    • Lotz, J.1    Meier, C.2    Leppert, A.3    Galanski, M.4
  • 2
    • 0026488274 scopus 로고
    • Arterial and venous blood flow: Noninvasive quantitation with MR imaging
    • Pelc LR, Pelc NJ, Rayhill SC, et al. Arterial and venous blood flow: noninvasive quantitation with MR imaging. Radiology 1992;185:809-812.
    • (1992) Radiology , vol.185 , pp. 809-812
    • Pelc, L.R.1    Pelc, N.J.2    Rayhill, S.C.3
  • 3
    • 0033959569 scopus 로고    scopus 로고
    • Blood flow measurement by magnetic resonance imaging in congenital heart disease
    • Powell AJ, Geva T. Blood flow measurement by magnetic resonance imaging in congenital heart disease. Pediatr Cardiol 2000;21:47-58.
    • (2000) Pediatr Cardiol , vol.21 , pp. 47-58
    • Powell, A.J.1    Geva, T.2
  • 4
    • 0025882906 scopus 로고
    • Right and left ventricular stroke volume measurements with velocity-encoded cine MR imaging: In vitro and in vivo validation
    • Kondo C, Caputo GR, Semelka R, Foster E, Shimakawa A, Higgins CB. Right and left ventricular stroke volume measurements with velocity-encoded cine MR imaging: in vitro and in vivo validation. AJR Am J Roentgenol 1991;157:9-16.
    • (1991) AJR Am J Roentgenol , vol.157 , pp. 9-16
    • Kondo, C.1    Caputo, G.R.2    Semelka, R.3    Foster, E.4    Shimakawa, A.5    Higgins, C.B.6
  • 5
    • 0034871769 scopus 로고    scopus 로고
    • Real-time interactive duplex MR measurements: Application in neurovascular imaging
    • Wetzel SG, Lee VS, Tan AG, et al. Real-time interactive duplex MR measurements: application in neurovascular imaging. AJR Am J Roentgenol 2001;177:703-707.
    • (2001) AJR Am J Roentgenol , vol.177 , pp. 703-707
    • Wetzel, S.G.1    Lee, V.S.2    Tan, A.G.3
  • 7
    • 0017198809 scopus 로고
    • Determination of pressure gradient in mitral stenosis with a non-invasive ultrasound Doppler technique
    • Holen J, Aaslid R, Landmark K, Simonsen S. Determination of pressure gradient in mitral stenosis with a non-invasive ultrasound Doppler technique. Acta Med Scand 1976;199:455-460.
    • (1976) Acta Med Scand , vol.199 , pp. 455-460
    • Holen, J.1    Aaslid, R.2    Landmark, K.3    Simonsen, S.4
  • 9
    • 0027194536 scopus 로고
    • Localized real-time velocity spectra determination
    • Hu BS, Pauly JM, Nishimura DG. Localized real-time velocity spectra determination. Magn Reson Med 1993;30:393-398.
    • (1993) Magn Reson Med , vol.30 , pp. 393-398
    • Hu, B.S.1    Pauly, J.M.2    Nishimura, D.G.3
  • 11
    • 33846926585 scopus 로고
    • Broadband nuclear magnetic resonance pulses with two-dimensional spatial selectivity
    • Hardy CJ, Cline HE. Broadband nuclear magnetic resonance pulses with two-dimensional spatial selectivity. J AppL Phys 1989;66:1513-1516.
    • (1989) J AppL Phys , vol.66 , pp. 1513-1516
    • Hardy, C.J.1    Cline, H.E.2
  • 12
    • 45149145242 scopus 로고
    • A k-space analysis of small-tip-angle excitation
    • Pauly JM, Nishimura DG, Macovski A. A k-space analysis of small-tip-angle excitation. J Magn Reson 1989;81:43-56.
    • (1989) J Magn Reson , vol.81 , pp. 43-56
    • Pauly, J.M.1    Nishimura, D.G.2    Macovski, A.3
  • 13
    • 0004220622 scopus 로고    scopus 로고
    • Bradley WG, editor. New York: Lippincott, Williams & Wilkins;
    • Hashemi, Bradley WG. MRI: the basics. Bradley WG, editor. New York: Lippincott, Williams & Wilkins; 1997. 307 p.
    • (1997) MRI: The Basics
    • Hashemi1    Bradley, W.G.2
  • 14
    • 0029121371 scopus 로고
    • Compensation of multi-dimensional selective excitation pulses using measured k-space trajectories
    • Takahashi A, Peters T. Compensation of multi-dimensional selective excitation pulses using measured k-space trajectories. Magn Reson Med 1995;34:446-456.
    • (1995) Magn Reson Med , vol.34 , pp. 446-456
    • Takahashi, A.1    Peters, T.2
  • 16
    • 0034983926 scopus 로고    scopus 로고
    • Intracranial arteriovenous malformations: Real-time auto-triggered elliptic centric-ordered 3D gadolinium-enhanced MR angiography - Initial assessment
    • Farb RI, McGregor C, Kim JK, et al. Intracranial arteriovenous malformations: real-time auto-triggered elliptic centric-ordered 3D gadolinium-enhanced MR angiography - initial assessment. Radiology 2001;220:244-251.
    • (2001) Radiology , vol.220 , pp. 244-251
    • Farb, R.I.1    McGregor, C.2    Kim, J.K.3
  • 18
    • 0035105431 scopus 로고    scopus 로고
    • Fast measurements of the motion and velocity spectrum of blood using MR tagging
    • Macgowan CK, Wood ML. Fast measurements of the motion and velocity spectrum of blood using MR tagging. Magn Reson Med 2001;45:461-469.
    • (2001) Magn Reson Med , vol.45 , pp. 461-469
    • Macgowan, C.K.1    Wood, M.L.2
  • 19
    • 0029157780 scopus 로고
    • Correction of intrinsic spectral broadening errors in Doppler peak velocity measurements made with phased sector and linear array transducers
    • Winkler AJ, Wu J. Correction of intrinsic spectral broadening errors in Doppler peak velocity measurements made with phased sector and linear array transducers. Ultrasound Med Biol 1995;21:1029-1035.
    • (1995) Ultrasound Med Biol , vol.21 , pp. 1029-1035
    • Winkler, A.J.1    Wu, J.2
  • 20
    • 0030065280 scopus 로고    scopus 로고
    • Accuracy of maximum velocity estimates made using Doppler ultrasound systems
    • Hoskins PR. Accuracy of maximum velocity estimates made using Doppler ultrasound systems. Br J Radiol 1996;69:172-177.
    • (1996) Br J Radiol , vol.69 , pp. 172-177
    • Hoskins, P.R.1
  • 21
    • 0035001406 scopus 로고    scopus 로고
    • Sources of error in maximum velocity estimation using linear phased-array Doppler systems with steady flow
    • Steinman AH, Tavakkoli J, Myers Jr JG, Cobbold RS, Johnston KW. Sources of error in maximum velocity estimation using linear phased-array Doppler systems with steady flow. Ultrasound Med Biol 2001;27:655-664.
    • (2001) Ultrasound Med Biol , vol.27 , pp. 655-664
    • Steinman, A.H.1    Tavakkoli, J.2    Myers Jr., J.G.3    Cobbold, R.S.4    Johnston, K.W.5
  • 23
    • 0037225732 scopus 로고    scopus 로고
    • Triggered real-time MRI and cardiac applications
    • Nayak KS, Hu BS. Triggered real-time MRI and cardiac applications. Magn Reson Med 2003;49:188-192.
    • (2003) Magn Reson Med , vol.49 , pp. 188-192
    • Nayak, K.S.1    Hu, B.S.2
  • 24
    • 0035061985 scopus 로고    scopus 로고
    • Rapid aortic wave velocity measurement with MR imaging
    • Itskovich W, Kraft KA, Fei DY. Rapid aortic wave velocity measurement with MR imaging. Radiology 2001;219:551-557.
    • (2001) Radiology , vol.219 , pp. 551-557
    • Itskovich, W.1    Kraft, K.A.2    Fei, D.Y.3
  • 25
    • 0032900423 scopus 로고    scopus 로고
    • Motion measurements from individual MR signals using volume localization
    • Macgowan CK, Wood ML. Motion measurements from individual MR signals using volume localization. J Magn Reson Imaging 1999;9:670-678.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 670-678
    • Macgowan, C.K.1    Wood, M.L.2
  • 26
    • 0036293405 scopus 로고    scopus 로고
    • Pulse-wave velocity measured in one heartbeat using MR tagging
    • Macgowan CK, Henkelman RM, Wood ML. Pulse-wave velocity measured in one heartbeat using MR tagging. Magn Reson Med 2002;48:115-121.
    • (2002) Magn Reson Med , vol.48 , pp. 115-121
    • Macgowan, C.K.1    Henkelman, R.M.2    Wood, M.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.