메뉴 건너뛰기




Volumn 21, Issue 5, 2007, Pages 295-300

Calcium phosphate cement augmentation of the femoral neck defect created after dynamic hip screw removal

Author keywords

Calcium phosphate cement; Failure strength; Internal fixation; Intertrochanteric hip fracture; Norian

Indexed keywords

CALCIUM PHOSPHATE;

EID: 34248230209     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e3180616ba5     Document Type: Article
Times cited : (34)

References (21)
  • 1
    • 0000561087 scopus 로고
    • Hip fractures: I. overview and evaluation and treatment of femoral-neck fractures
    • Koval KJ, Zuckerman JD. Hip fractures: I. overview and evaluation and treatment of femoral-neck fractures. J Am Acad Orthop Surg. 1994;2:141-149.
    • (1994) J Am Acad Orthop Surg , vol.2 , pp. 141-149
    • Koval, K.J.1    Zuckerman, J.D.2
  • 2
    • 0030931408 scopus 로고    scopus 로고
    • Clinical outcomes and treatment of hip fractures
    • discussion S-4S
    • Lyons AR. Clinical outcomes and treatment of hip fractures. Am J Med. 1997;103:51S-63S; discussion S-4S.
    • (1997) Am J Med , vol.103
    • Lyons, A.R.1
  • 3
    • 0029890161 scopus 로고    scopus 로고
    • Hip fracture
    • Zuckerman JD. Hip fracture. N Engl J Med. 1996;334:1519-1525.
    • (1996) N Engl J Med , vol.334 , pp. 1519-1525
    • Zuckerman, J.D.1
  • 4
    • 33745975434 scopus 로고    scopus 로고
    • Finite element study of the proximal femur with retained trochanteric gamma nail and after removal of nail
    • Mahaisavariya B, Sitthiseripratip K, Suwanprateeb J. Finite element study of the proximal femur with retained trochanteric gamma nail and after removal of nail. Injury. 2006;37:778-785.
    • (2006) Injury , vol.37 , pp. 778-785
    • Mahaisavariya, B.1    Sitthiseripratip, K.2    Suwanprateeb, J.3
  • 5
    • 0034759555 scopus 로고    scopus 로고
    • Femoral neck fracture after removal of the standard gamma interlocking nail: A cadaveric study to determine factors influencing the biomechanical properties of the proximal femur
    • Kukla C, Pichl W, Prokesch R, et al. Femoral neck fracture after removal of the standard gamma interlocking nail: a cadaveric study to determine factors influencing the biomechanical properties of the proximal femur. J Biomech. 2001;34:1519-1526.
    • (2001) J Biomech , vol.34 , pp. 1519-1526
    • Kukla, C.1    Pichl, W.2    Prokesch, R.3
  • 8
    • 0025818038 scopus 로고
    • Healing of residual screw holes after plate removal
    • Rosson J, Murphy W, Tonge C, et al. Healing of residual screw holes after plate removal. Injury. 1991;22:383-384.
    • (1991) Injury , vol.22 , pp. 383-384
    • Rosson, J.1    Murphy, W.2    Tonge, C.3
  • 9
    • 0025924658 scopus 로고
    • Bone weakness after the removal of plates and screws. Cortical atrophy or screw holes?
    • Rosson J, Egan J, Shearer J, et al. Bone weakness after the removal of plates and screws. Cortical atrophy or screw holes? J Bone Joint Surg Br. 1991;73:283-286.
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 283-286
    • Rosson, J.1    Egan, J.2    Shearer, J.3
  • 10
    • 0025075705 scopus 로고
    • Refracture after removal of a condylar plate from the distal third of the femur
    • Bostman OM. Refracture after removal of a condylar plate from the distal third of the femur. J Bone Joint Surg Am. 1990;72:1013-1018.
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 1013-1018
    • Bostman, O.M.1
  • 11
    • 0030338875 scopus 로고    scopus 로고
    • Refracture risk after plate removal in the forearm
    • Beaupre GS, Csongradi JJ. Refracture risk after plate removal in the forearm. J Orthop Trauma. 1996;10:87-92.
    • (1996) J Orthop Trauma , vol.10 , pp. 87-92
    • Beaupre, G.S.1    Csongradi, J.J.2
  • 12
    • 0031712261 scopus 로고    scopus 로고
    • Biomechanical and histological evaluation of a calcium phosphate cement
    • Frankenburg EP, Goldstein SA, Bauer TW, et al. Biomechanical and histological evaluation of a calcium phosphate cement. J Bone Joint Surg Am. 1998;80-88:1112-1124.
    • (1998) J Bone Joint Surg Am
    • Frankenburg, E.P.1    Goldstein, S.A.2    Bauer, T.W.3
  • 13
    • 0031924185 scopus 로고    scopus 로고
    • Norian SRS cement augmentation in hip fracture treatment. Laboratory and initial clinical results
    • Goodman SB, Bauer TW, Carter D, et al. Norian SRS cement augmentation in hip fracture treatment. Laboratory and initial clinical results. Clin Orthop Relat Res. 1998;348:42-50.
    • (1998) Clin Orthop Relat Res , vol.348 , pp. 42-50
    • Goodman, S.B.1    Bauer, T.W.2    Carter, D.3
  • 14
    • 0036169004 scopus 로고    scopus 로고
    • Use of injectable calcium phosphate cement for fracture fixation: A review
    • Larsson S, Bauer TW. Use of injectable calcium phosphate cement for fracture fixation: a review. Clin Orthop Relat Res. 2002;395:23-32.
    • (2002) Clin Orthop Relat Res , vol.395 , pp. 23-32
    • Larsson, S.1    Bauer, T.W.2
  • 15
    • 0029256548 scopus 로고
    • Skeletal repair by in situ formation of the mineral phase of bone
    • Constantz BR, Ison IC, Fulmer MT, et al. Skeletal repair by in situ formation of the mineral phase of bone. Science. 1995;267:1796-1799.
    • (1995) Science , vol.267 , pp. 1796-1799
    • Constantz, B.R.1    Ison, I.C.2    Fulmer, M.T.3
  • 16
    • 0030250814 scopus 로고    scopus 로고
    • Augmentation of femoral neck fracture fixation with an injectable calcium-phosphate bone mineral cement
    • Stankewich CJ, Swiontkowski MF, Tencer AF, et al. Augmentation of femoral neck fracture fixation with an injectable calcium-phosphate bone mineral cement. J Orthop Res. 1996;14:786-793.
    • (1996) J Orthop Res , vol.14 , pp. 786-793
    • Stankewich, C.J.1    Swiontkowski, M.F.2    Tencer, A.F.3
  • 17
    • 0029012764 scopus 로고
    • The value of the tipapex distance in predicting failure of fixation of peritrochanteric fractures of the hip
    • Baumgaertner MR, Curtin SL, Lindskog DM, et al. The value of the tipapex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am. 1995;77:1058-1064.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1058-1064
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3
  • 18
    • 0030720275 scopus 로고    scopus 로고
    • Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip
    • Baumgaertner MR, Solberg BD. Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br. 1997;79:969-971.
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 969-971
    • Baumgaertner, M.R.1    Solberg, B.D.2
  • 19
    • 0036125795 scopus 로고    scopus 로고
    • The effect of posterior sag on the fixation stability of intertrochanteric hip fractures
    • Joseph TN, Chen AL, Kummer FJ, et al. The effect of posterior sag on the fixation stability of intertrochanteric hip fractures. J Trauma. 2002;52:544-547.
    • (2002) J Trauma , vol.52 , pp. 544-547
    • Joseph, T.N.1    Chen, A.L.2    Kummer, F.J.3
  • 20
    • 2942626200 scopus 로고    scopus 로고
    • Femoroplasty-augmentation of mechanical properties in the osteoporotic proximal femur: A biomechanical investigation of PMMA reinforcement in cadaver bones
    • Heini PF, Franz T, Fankhauser C, et al. Femoroplasty-augmentation of mechanical properties in the osteoporotic proximal femur: a biomechanical investigation of PMMA reinforcement in cadaver bones. Clin Biomech (Bristol, Avon). 2004;19:506-512.
    • (2004) Clin Biomech (Bristol, Avon) , vol.19 , pp. 506-512
    • Heini, P.F.1    Franz, T.2    Fankhauser, C.3
  • 21
    • 33645788865 scopus 로고    scopus 로고
    • Calcium phosphate cement for augmentation did not improve results after internal fixation of displaced femoral neck fractures: A randomized study of 118 patients
    • Mattsson P, Larsson S. Calcium phosphate cement for augmentation did not improve results after internal fixation of displaced femoral neck fractures: a randomized study of 118 patients. Acta Orthop. 2006;77:251-256.
    • (2006) Acta Orthop , vol.77 , pp. 251-256
    • Mattsson, P.1    Larsson, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.