-
1
-
-
0037462991
-
Lab-on-A-chip for drug development
-
DOI 10.1016/S0169-409X(02)00223-5
-
B. H. Weigl, R. L. Bardell, and C. R. Cabrera, "Lab-on-a-chip for drug development," Adv. Drug Delivery Rev. 55, 349-377 (2003). (Pubitemid 36297054)
-
(2003)
Advanced Drug Delivery Reviews
, vol.55
, Issue.3
, pp. 349-377
-
-
Weigl, B.H.1
Bardell, R.L.2
Cabrera, C.R.3
-
2
-
-
0242385629
-
An integrated microfluidic system for reaction, high-sensitivity detection, and sorting of fluorescent cells and particles
-
DOI 10.1021/ac034568c
-
P. S. Dittrich and P. Schwille, "An integrated microfluidic system for reaction, high-sensitivity detection, and sorting of fluorescent cells and particles," Anal. Chem. 75, 5767-5774 (2003). (Pubitemid 37356457)
-
(2003)
Analytical Chemistry
, vol.75
, Issue.21
, pp. 5767-5774
-
-
Dittrich, P.S.1
Schwille, P.2
-
3
-
-
0037086157
-
DNA fragment sizing by single molecule detection in submicrometer-sized closed fluidic channels
-
DOI 10.1021/ac011076w
-
M. Foquet, J. Korlach, W. Zipfel, W. W. Webb, and H. G. Craighead, "DNA fragment sizing by single molecule detection in submicrometer-sized closed fluidic channels," Anal. Chem. 74, 1415-1422 (2002). (Pubitemid 34233334)
-
(2002)
Analytical Chemistry
, vol.74
, Issue.6
, pp. 1415-1422
-
-
Foquet, M.1
Korlach, J.2
Zipfel, W.3
Webb, W.W.4
Craighead, H.G.5
-
4
-
-
0032524099
-
Chemical amplification: Continuous-flow PCR on a chip
-
DOI 10.1126/science.280.5366.1046
-
M. U. Kopp, A. J. Mello, and A. Manz, "Chemical amplification: continuous-flow PCR on a chip," Science 280, 1046-1048 (1998). (Pubitemid 28234939)
-
(1998)
Science
, vol.280
, Issue.5366
, pp. 1046-1048
-
-
Kopp, M.U.1
De Mello, A.J.2
Manz, A.3
-
5
-
-
18444370256
-
A microfabricated array bioreactor for perfused 3D liver culture
-
DOI 10.1002/bit.10143
-
M. J. Powers, K. Domansky, M. R. Kaazempur-Mofrad, A. Kalezi, A. Capitano, A. Upadhyaya, P. Kurzawski, K. E. Wack, D. B. Stolz, R. Kamm, and L. G. Griffith, "A microfabricated array bioreactor for perfused 3D liver culture," Biotechnol. Bioeng. 78, 257-269 (2002). (Pubitemid 34712370)
-
(2002)
Biotechnology and Bioengineering
, vol.78
, Issue.3
, pp. 257-269
-
-
Powers, M.J.1
Domansky, K.2
Kaazempur-Mofrad, M.R.3
Kalezi, A.4
Capitano, A.5
Upadhyaya, A.6
Kurzawski, P.7
Wack, K.E.8
Stolz, D.B.9
Kamm, R.10
Griffith, L.G.11
-
6
-
-
0033993750
-
Silicon micromachining to tissue engineer branched vascular channels for liver fabrication
-
DOI 10.1089/107632700320739
-
S. Kaihara, J. Borenstein, R. Koka, S. Lalan, E. R. Ochoa, M. Ravens, H. Pien, B. Cunningham, and J. P. Vacanti, "Silicon micromachining to tissue engineer branched vascular channels for liver fabrication," Tissue Eng. 6, 105-117 (2000). (Pubitemid 30227167)
-
(2000)
Tissue Engineering
, vol.6
, Issue.2
, pp. 105-117
-
-
Kaihara, S.1
Borenstein, J.2
Koka, R.3
Lalan, S.4
Ochoa, E.R.5
Ravens, M.6
Pien, H.7
Cunningham, B.8
Vacanti, J.P.9
-
7
-
-
20544466084
-
A configurable three-dimensional microenvironment in a microfluidic channel for primary hepatocyte culture
-
DOI 10.1089/adt.2005.3.169
-
Y. C. Toh, S. Ng, Y. M. Khong, V. Samper, and H. Yu, "A configurable three-dimensional microenvironment in a microfluidic channel for primary hepatocyte culture," Assay Drug Dev. Technol. 3, 169-176 (2005). (Pubitemid 40846886)
-
(2005)
Assay and Drug Development Technologies
, vol.3
, Issue.2
, pp. 169-176
-
-
Toh, Y.-C.1
Ng, S.2
Khong, Y.M.3
Samper, V.4
Yu, H.5
-
8
-
-
0038311020
-
Near-wall μ-PIV reveals a hydrodynamically relevant endothelial surface layer in venules in vivo
-
M. L. Smith, D. S. Long, E. R. Damiano, and K. Ley, "Near-wall micro-PIV reveals a hydrodynamically relevant endothelial surface layer in venules in vivo," Biophys. J. 85, 637-645 (2003). (Pubitemid 36753665)
-
(2003)
Biophysical Journal
, vol.85
, Issue.1
, pp. 637-645
-
-
Smith, M.L.1
Long, D.S.2
Damiano, E.R.3
Ley, K.4
-
9
-
-
0036009565
-
Real-time in vivo color Doppler optical coherence tomography
-
DOI 10.1117/1.1428291
-
A. M. Rollins, S. Yazdanfar, J. K. Barton, and J. A. Izatt, "Real-time in vivo color Doppler optical coherence tomography," J. Biomed. Opt. 7, 123-129 (2002). (Pubitemid 34278420)
-
(2002)
Journal of Biomedical Optics
, vol.7
, Issue.1
, pp. 123-129
-
-
Rollins, A.M.1
Yazdanfar, S.2
Barton, J.K.3
Izatt, J.A.4
-
10
-
-
0037426379
-
Noninvasive determination of coronary blood flow velocity with cardiovascular magnetic resonance in patients after stent deployment
-
DOI 10.1161/01.CIR.0000060542.79482.81
-
E. Nagel, T. Thouet, C. Klein, S. Schalla, A. Bornstedt, B. Schnackenburg, J. Hug, E. Wellnhofer, and E. Fleck, "Noninvasive determination of coronary blood flow velocity with cardiovascular magnetic resonance in patients after stent deployment," Circulation 107, 1738-1743 (2003). (Pubitemid 36418353)
-
(2003)
Circulation
, vol.107
, Issue.13
, pp. 1738-1743
-
-
Nagel, E.1
Thouet, T.2
Klein, C.3
Schalla, S.4
Bornstedt, A.5
Schnackenburg, B.6
Hug, J.7
Wellnhofer, E.8
Fleck, E.9
-
11
-
-
0032154939
-
A particle image velocimetry system for microfluidics
-
J. G. Santiago, S. T. Wereley, C. D. Meinhart, D. J. Beebe, and R. J. Adrian, "A particle image velocimetry system for microfluidics," Exp. Fluids 25, 316-319 (1998). (Pubitemid 128663106)
-
(1998)
Experiments in Fluids
, vol.25
, Issue.4
, pp. 316-319
-
-
Santiago, J.G.1
Wereley, S.T.2
Meinhart, C.D.3
Beebe, D.J.4
Adrian, R.J.5
-
12
-
-
0141644107
-
Modified laser speckle imaging method with improved spatial resolution
-
H. Cheng, Q. Luo, S. Zeng, S. Chen, J. Cen, and H. Gong, "Modified laser speckle imaging method with improved spatial resolution," J. Biomed. Opt. 8, 559-564 (2003).
-
(2003)
J. Biomed. Opt.
, vol.8
, pp. 559-564
-
-
Cheng, H.1
Luo, Q.2
Zeng, S.3
Chen, S.4
Cen, J.5
Gong, H.6
-
13
-
-
0029357407
-
Optical trapping and fluorescence detection in laminar flow streams
-
W. Wang, Y. Liu, G. J. Sonek, M. W. Berns, and R. A. Keller, "Optical trapping and fluorescence detection in laminar flow streams," Appl. Phys. Lett. 67, 1057-1059 (1995).
-
(1995)
Appl. Phys. Lett.
, vol.67
, pp. 1057-1059
-
-
Wang, W.1
Liu, Y.2
Sonek, G.J.3
Berns, M.W.4
Keller, R.A.5
-
14
-
-
0001030021
-
NMR imaging of the time evolution of electroosmotic flow in a capillary
-
B. Manz, P. Stilbs, B. Joensson, O. Soederman, and P. T. Callaghan, "NMR imaging of the time evolution of electroosmotic flow in a capillary," J. Phys. Chem. 99, 11297-11301 (1995).
-
(1995)
J. Phys. Chem.
, vol.99
, pp. 11297-11301
-
-
Manz, B.1
Stilbs, P.2
Joensson, B.3
Soederman, O.4
Callaghan, P.T.5
-
15
-
-
0016379116
-
Fluorescence correlation spectroscopy. I. Conceptual basis and theory
-
E. L. Elson and D. Magde, "Fluorescence correlation spectroscopy. I. Conceptual basis and theory," Biopolymers 13, 1-27 (1974).
-
(1974)
Biopolymers
, vol.13
, pp. 1-27
-
-
Elson, E.L.1
Magde, D.2
-
16
-
-
0017801658
-
Fluorescence correlation spectroscopy. III. Uniform translation and laminar flow
-
DOI 10.1002/bip.1978.360170208
-
D. Magde, W. W. Webb, and E. L. Elson, "Fluorescence correlation spectroscopy. III. uniform translation and laminar flow," Biopolymers 17, 361-376 (1978). (Pubitemid 8317012)
-
(1978)
Biopolymers
, vol.17
, Issue.2
, pp. 361-376
-
-
Magde, D.1
Webb, W.W.2
Elson, E.L.3
-
17
-
-
0034472564
-
Active protein transport through plastid tubules: Velocity quantified by fluorescence correlation spectroscopy
-
R. H. Kohler, P. Schwille, W. W. Webb, and M. R. Hanson, "Active protein transport through plastid tubules: velocity quantified by fluorescence correlation spectroscopy," J. Cell. Sci. 113, 3921-3930 (2000). (Pubitemid 32194517)
-
(2000)
Journal of Cell Science
, vol.113
, Issue.22
, pp. 3921-3930
-
-
Kohler, R.H.1
Schwille, P.2
Webb, W.W.3
Hanson, M.R.4
-
18
-
-
0037108804
-
Detection of flowing fluorescent particles in a microcapillary using fluorescence correlation spectroscopy
-
DOI 10.1021/ac0256742
-
B. H. Kunst, A. Schots, and A. J. Visser, "Detection of flowing fluorescent particles in a microcapillary using fluorescence correlation spectroscopy," Anal. Chem. 74, 5350-5357 (2002). (Pubitemid 35215367)
-
(2002)
Analytical Chemistry
, vol.74
, Issue.20
, pp. 5350-5357
-
-
Kunst, B.H.1
Schots, A.2
Visser, A.J.W.G.3
-
19
-
-
0043141470
-
Hydrodynamic flow profiling in microchannel structures by single molecule fluorescence correlation spectroscopy
-
DOI 10.1021/ac991448p
-
M. Gosch, H. Blom, J. Holm, T. Heino, and R. Rigler, "Hydrodynamic flow profiling in microchannel structures by single molecule fluorescence correlation spectroscopy," Anal. Chem. 72, 3260-3265 (2000). (Pubitemid 30482501)
-
(2000)
Analytical Chemistry
, vol.72
, Issue.14
, pp. 3260-3265
-
-
Gosch, M.1
Blom, H.2
Holm, J.3
Heino, T.4
Rigler, R.5
-
20
-
-
8344246220
-
Application of fluorescence correlation spectroscopy for velocity imaging in microfluidic devices
-
K. K. Kuricheti, V. Buschmann, and K. D. Weston, "Application of fluorescence correlation spectroscopy for velocity imaging in microfluidic devices," Appl. Spectrosc. 58, 1180-1186 (2004).
-
(2004)
Appl. Spectrosc.
, vol.58
, pp. 1180-1186
-
-
Kuricheti, K.K.1
Buschmann, V.2
Weston, K.D.3
-
21
-
-
0036383878
-
Flow profiles and directionality in microcapillaries measured by fluorescence correlation spectroscopy
-
P. F. Lenne, D. Colombo, H. Giovannini, and H. Rigneault, "Flow profiles and directionality in microcapillaries measured by fluorescence correlation spectroscopy," Single Mol. 3, 194-200 (2002).
-
(2002)
Single Mol.
, vol.3
, pp. 194-200
-
-
Lenne, P.F.1
Colombo, D.2
Giovannini, H.3
Rigneault, H.4
-
22
-
-
0040437357
-
Two-beam cross-correlation: A method to characterize transport phenomena in micrometer-sized structures
-
M. Brinkmeier, K. Dorre, J. Stephan, and M. Eigen, "Two-beam cross-correlation: a method to characterize transport phenomena in micrometer-sized structures," Anal. Chem. 71, 609-616 (1999).
-
(1999)
Anal. Chem.
, vol.71
, pp. 609-616
-
-
Brinkmeier, M.1
Dorre, K.2
Stephan, J.3
Eigen, M.4
-
23
-
-
0000545874
-
Dual-beam incoherent cross-correlation spectroscopy
-
K. Q. Xia and Y. B. Xin, "Dual-beam incoherent cross-correlation spectroscopy," J. Opt. Soc. Am. A 12, 1571-1578 (1995).
-
(1995)
J. Opt. Soc. Am. A
, vol.12
, pp. 1571-1578
-
-
Xia, K.Q.1
Xin, Y.B.2
-
24
-
-
0036711662
-
Spatial two-photon fluorescence cross-correlation spectroscopy for controlling molecular transport in microfluidic structures
-
DOI 10.1021/ac025625p
-
P. S. Dittrich and P. Schwille, "Spatial two-photon fluorescence crosscorrelation spectroscopy for controlling molecular transport in microfluidic structures," Anal. Chem. 74, 4472-4479 (2002). (Pubitemid 35006436)
-
(2002)
Analytical Chemistry
, vol.74
, Issue.17
, pp. 4472-4479
-
-
Dittrich, P.S.1
Schwille, P.2
-
25
-
-
0022545162
-
Scanning fluorescence correlation spectroscopy. I. Theory and simulation of aggregation measurements
-
N. O. Petersen, "Scanning fluorescence correlation spectroscopy. I. Theory and simulation of aggregation measurements," Biophys. J. 49, 809-815 (1986). (Pubitemid 16074707)
-
(1986)
Biophysical Journal
, vol.49
, Issue.4
, pp. 809-815
-
-
Petersen, N.O.1
-
26
-
-
0028012733
-
Scanning concentration correlation spectroscopy using the confocal laser microscope
-
D. E. Koppel, F. Morgan, A. E. Cowan, and J. H. Carson, "Scanning concentration correlation spectroscopy using the confocal laser microscope," Biophys. J. 66, 502-507 (1994). (Pubitemid 24058468)
-
(1994)
Biophysical Journal
, vol.66
, Issue.2
, pp. 502-507
-
-
Koppel, D.E.1
Morgan, F.2
Cowan, A.E.3
Carson, J.H.4
-
27
-
-
0029977148
-
Scanning two-photon fluctuation correlation spectroscopy: Particle counting measurements for detection of molecular aggregation
-
K. M. Berland, P. T. So, Y. Chen, W. W. Mantulin, and E. Gratton, "Scanning two-photon fluctuation correlation spectroscopy: particle counting measurements for detection of molecular aggregation," Biophys. J. 71, 410-420 (1996). (Pubitemid 26227327)
-
(1996)
Biophysical Journal
, vol.71
, Issue.1
, pp. 410-420
-
-
Berland, K.M.1
So, P.T.C.2
Chen, Y.3
Mantulin, W.W.4
Gratton, E.5
-
28
-
-
17844395707
-
Spatiotemporal image correlation spectroscopy (STICS) theory, verification, and application to protein velocity mapping in living CHO cells
-
DOI 10.1529/biophysj.104.054874
-
B. Hebert, S. Costantino, and P. W. Wiseman, "Spatiotemporal image correlation spectroscopy (STICS( theory, verification, and application to protein velocity mapping in living CHO cells," Biophys. J. 88, 3601-3614 (2005). (Pubitemid 40586608)
-
(2005)
Biophysical Journal
, vol.88
, Issue.5
, pp. 3601-3614
-
-
Hebert, B.1
Costantino, S.2
Wiseman, P.W.3
-
29
-
-
23244464964
-
Position-sensitive scanning fluorescence correlation spectroscopy
-
J. P. Skinner, Y. Chen, and J. D. Muller, "Position-sensitive scanning fluorescence correlation spectroscopy," Biophys. J. 89, 1288-1301
-
Biophys. J.
, vol.89
, pp. 1288-1301
-
-
Skinner, J.P.1
Chen, Y.2
Muller, J.D.3
-
30
-
-
0027317178
-
Fluorescence correlation spectroscopy with high count rate and low background: Analysis of translational diffusion
-
R. Rigler, U. Mets, J. Widengren, and P. Kask, "Fluorescence correlation spectroscopy with high count rate and low background: analysis of translational diffusion," Eur. Biophys. J. 22, 169-175 (1993). (Pubitemid 23279495)
-
(1993)
European Biophysics Journal
, vol.22
, Issue.3
, pp. 169-175
-
-
Rigler, R.1
Mets, U.2
Widengren, J.3
Kask, P.4
-
31
-
-
0039025943
-
Fluorescence correlation spectroscopy of triplet states in solution: A theoretical and experimental study
-
J. Widengren, U. Mets, and R. Rigler, "Fluorescence correlation spectroscopy of triplet states in solution: a theoretical and experimental study," J. Phys. Chem. 99, 13368-13379 (1995).
-
(1995)
J. Phys. Chem.
, vol.99
, pp. 13368-13379
-
-
Widengren, J.1
Mets, U.2
Rigler, R.3
-
33
-
-
0000397420
-
Statistical accuracy in fluorescence correlation spectroscopy
-
D. E. Koppel, "Statistical accuracy in fluorescence correlation spectroscopy," Phys. Rev. A 10, 1938-1945 (1974).
-
(1974)
Phys. Rev. A
, vol.10
, pp. 1938-1945
-
-
Koppel, D.E.1
-
34
-
-
0035010214
-
The standard deviation in fluorescence correlation spectroscopy
-
T. Wohland, R. Rigler, and H. Vogel, "The standard deviation in fluorescence correlation spectroscopy," Biophys. J. 80, 2987-2999 (2001). (Pubitemid 32521670)
-
(2001)
Biophysical Journal
, vol.80
, Issue.6
, pp. 2987-2999
-
-
Wohland, T.1
Rigler, R.2
Vogel, H.3
-
35
-
-
0033021689
-
Resolution of fluorescence correlation measurements
-
U. Meseth, T. Wohland, R. Rigler, and H. Vogel, "Resolution of fluorescence correlation measurements," Biophys. J. 76, 1619-1631 (1999). (Pubitemid 29262640)
-
(1999)
Biophysical Journal
, vol.76
, Issue.3
, pp. 1619-1631
-
-
Meseth, U.1
Wohland, T.2
Rigler, R.3
Vogel, H.4
-
36
-
-
0035865186
-
The vascular anatomy of the developing zebrafish: An atlas of embryonic and early larval development
-
DOI 10.1006/dbio.2000.9995
-
S. Isogai, M. Horiguchi, and B. M. Weinstein, "The vascular anatomy of the developing zebrafish: an atlas of embryonic and early larval development," Dev. Biol. 230, 278-301 (2001). (Pubitemid 32171423)
-
(2001)
Developmental Biology
, vol.230
, Issue.2
, pp. 278-301
-
-
Isogai, S.1
Horiguchi, M.2
Weinstein, B.M.3
|