Volumn 27, Issue 3, 2007, Pages 281-286

Systematic measurement errors involved in over-refraction using an autorefractor (Grand-Seiko WV-500): Is measurement of accommodative lag through spectacle lenses valid?

Author keywords

Autorefractor; Lag of accommodation; Myopia; Over refraction; Systematic measurement error

Indexed keywords

ACCOMMODATION DISORDER; ADULT; ARTICLE; ARTIFACT; AUTOREFRACTOR; CLINICAL ARTICLE; CONTROLLED STUDY; DEVICE; FEMALE; HUMAN; HYPERMETROPIA; MALE; MYOPIA; PRIORITY JOURNAL; REFRACTION ERROR; SIMULATION; SPECTACLES;

EID: 34247571990     PISSN: 02755408     EISSN: 14751313     Source Type: Journal    
DOI: 10.1111/j.1475-1313.2007.00466.x     Document Type: Article
Times cited : (15)

References (22)
  • 1
    • 0031982727 scopus 로고    scopus 로고
    • Difference in the stimulus response curves of adult myopes and emmetropes
    • Abbott, M. L., Schmid, K. L. Strang, N. C. (1998) Difference in the stimulus response curves of adult myopes and emmetropes. Ophthalmic. Physiol. Opt. 18, 13 20.
    • (1998) Ophthalmic. Physiol. Opt. , vol.18 , pp. 13-20
    • Abbott, M.L.1    Schmid, K.L.2    Strang, N.C.3
  • 2
    • 0035154816 scopus 로고    scopus 로고
    • Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in children
    • Chat, S. W. Edwards, M. H. (2001) Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in children. Ophthalmic. Physiol. Opt. 21, 87 100.
    • (2001) Ophthalmic. Physiol. Opt. , vol.21 , pp. 87-100
    • Chat, S.W.1    Edwards, M.H.2
  • 3
    • 0027447250 scopus 로고
    • Myopic children show insufficient accommodative response to blur
    • Gwiazda, J., Thorn, F., Bauer, J. Held, R. (1993) Myopic children show insufficient accommodative response to blur. Invest. Ophthalmol. Vis. Sci. 34, 690 694.
    • (1993) Invest. Ophthalmol. Vis. Sci. , vol.34 , pp. 690-694
    • Gwiazda, J.1    Thorn, F.2    Bauer, J.3    Held, R.4
  • 4
    • 3142654683 scopus 로고    scopus 로고
    • Accommodation and related risk factors associated with myopia progression and their interaction with treatment in COMET children
    • COMET group (
    • Gwiazda, J., Hyman, L., Norton, T. T., Hussein, M., Marsh-Tootle, W., Manny, R., Wang, Y. Everett, D., COMET group (2004) Accommodation and related risk factors associated with myopia progression and their interaction with treatment in COMET children. Invest. Ophthalmol. Vis. Sci. 45, 2143 2151.
    • (2004) Invest. Ophthalmol. Vis. Sci. , vol.45 , pp. 2143-2151
    • Gwiazda, J.1    Hyman, L.2    Norton, T.T.3    Hussein, M.4    Marsh-Tootle, W.5    Manny, R.6    Wang, Y.7    Everett, D.8
  • 6
    • 13844256493 scopus 로고    scopus 로고
    • Myopia control trial with progressive addition lenses in Japanese schoolchildren: Baseline measures of refraction, accommodation, heterophoria
    • Hasebe, S., Nonaka, F., Nakatsuka, C. Ohtsuki, H. (2005) Myopia control trial with progressive addition lenses in Japanese schoolchildren: baseline measures of refraction, accommodation, heterophoria. Jpn. J. Ophthalmol. 49, 23 30.
    • (2005) Jpn. J. Ophthalmol. , vol.49 , pp. 23-30
    • Hasebe, S.1    Nonaka, F.2    Nakatsuka, C.3    Ohtsuki, H.4
  • 7
    • 0029082674 scopus 로고
    • Spectacle lenses alter eye growth and the refractive status of young monkeys
    • Hung, L. F., Crawford, M. L. Smith, E. L. (1995) Spectacle lenses alter eye growth and the refractive status of young monkeys. Nat. Med. 1, 761 765.
    • (1995) Nat. Med. , vol.1 , pp. 761-765
    • Hung, L.F.1    Crawford, M.L.2    Smith, E.L.3
  • 11
    • 0022588533 scopus 로고
    • The effect of refractive error on the accommodative response gradient
    • McBrien, N. A. Millodot, M. (1986) The effect of refractive error on the accommodative response gradient. Ophthalmic. Physiol. Opt. 6, 145 149.
    • (1986) Ophthalmic. Physiol. Opt. , vol.6 , pp. 145-149
    • McBrien, N.A.1    Millodot, M.2
  • 12
    • 0042787042 scopus 로고    scopus 로고
    • The repeatability and validity of dynamic retinoscopy in assessing the accommodative response
    • McClelland, J. F. Saunders, K. J. (2003) The repeatability and validity of dynamic retinoscopy in assessing the accommodative response. Ophthalmic. Physiol. Opt. 23, 243 250.
    • (2003) Ophthalmic. Physiol. Opt. , vol.23 , pp. 243-250
    • McClelland, J.F.1    Saunders, K.J.2
  • 13
    • 0023913645 scopus 로고
    • Changing size (looming) as a stimulus to accommodation and vergence
    • McLin, L. N. Jr., Schor, C. M. Kruger, P. B. (1988) Changing size (looming) as a stimulus to accommodation and vergence. Vision Res. 28, 883 898.
    • (1988) Vision Res. , vol.28 , pp. 883-898
    • McLin Jr., L.N.1    Schor, C.M.2    Kruger, P.B.3
  • 14
    • 0037686657 scopus 로고    scopus 로고
    • Accommodative lag under habitual seeing conditions: Comparison between adult myopes and emmetropes
    • Nakatsuka, C., Hasebe, S., Nonaka, F. Ohtsuki, H. (2003) Accommodative lag under habitual seeing conditions: comparison between adult myopes and emmetropes. Jpn. J. Ophthalmol. 47, 291 298.
    • (2003) Jpn. J. Ophthalmol. , vol.47 , pp. 291-298
    • Nakatsuka, C.1    Hasebe, S.2    Nonaka, F.3    Ohtsuki, H.4
  • 15
    • 21144444947 scopus 로고    scopus 로고
    • Accommodative lag under habitual seeing conditions: Comparison between myopic and emmetropic children
    • Nakatsuka, C., Hasebe, S., Nonaka, F. Ohtsuki, H. (2005) Accommodative lag under habitual seeing conditions: comparison between myopic and emmetropic children. Jpn. J. Ophthalmol. 49, 189 194.
    • (2005) Jpn. J. Ophthalmol. , vol.49 , pp. 189-194
    • Nakatsuka, C.1    Hasebe, S.2    Nonaka, F.3    Ohtsuki, H.4
  • 16
    • 0029115357 scopus 로고
    • Repeatability of subjective and objective refraction
    • Rosenfield, M. Chiu, N. N. (1995) Repeatability of subjective and objective refraction. Optom. Vis. Sci. 72, 577 579.
    • (1995) Optom. Vis. Sci. , vol.72 , pp. 577-579
    • Rosenfield, M.1    Chiu, N.N.2
  • 17
    • 0036226246 scopus 로고    scopus 로고
    • Do progressing myopes show reduced accommodative response
    • Rosenfield, M., Desai, R. Portello, J. K. (2002) Do progressing myopes show reduced accommodative response Optom. Vis. Sci. 79, 268 273.
    • (2002) Optom. Vis. Sci. , vol.79 , pp. 268-273
    • Rosenfield, M.1    Desai, R.2    Portello, J.K.3
  • 18
    • 0001886016 scopus 로고    scopus 로고
    • Environmentally induced refractive errors in animal
    • In: eds. M. Rosenfield. B. Gilmartin. Butterworth Heinemann, Oxford, pp.
    • Smith, E. (1998) Environmentally induced refractive errors in animal. In : Myopia and Near Work (eds M. Rosenfield B. Gilmartin Butterworth Heinemann, Oxford, pp. 57 90.
    • (1998) Myopia and Near Work , pp. 57-90
    • Smith, E.1
  • 19
    • 0031171614 scopus 로고    scopus 로고
    • Power vectors: An application of Fourier analysis to the description and statistical analysis of refractive error
    • Thibos, L. N., Wheeler, W. Horner, D. (1997) Power vectors: an application of Fourier analysis to the description and statistical analysis of refractive error. Optom. Vis. Sci. 74, 367 375.
    • (1997) Optom. Vis. Sci. , vol.74 , pp. 367-375
    • Thibos, L.N.1    Wheeler, W.2    Horner, D.3
  • 20
    • 0035153922 scopus 로고    scopus 로고
    • Continuous recording of accommodation and pupil size using the Shin-Nippon SRW-5000 autorefractor
    • Wolffsohn, J. S., Gilmartin, B., Mallen, E. A. Tsujimura, S. (2001) Continuous recording of accommodation and pupil size using the Shin-Nippon SRW-5000 autorefractor. Ophthalmic. Physiol. Opt. 21, 108 113.
    • (2001) Ophthalmic. Physiol. Opt. , vol.21 , pp. 108-113
    • Wolffsohn, J.S.1    Gilmartin, B.2    Mallen, E.A.3    Tsujimura, S.4
  • 21
    • 3142655869 scopus 로고    scopus 로고
    • Simultaneous continuous recording of accommodation and pupil size using the modified Shin-Nippon SRW-5000 autorefractor
    • Wolffsohn, J. S., O'Donnell, C., Charman, W. N. Gilmartin, B. (2004) Simultaneous continuous recording of accommodation and pupil size using the modified Shin-Nippon SRW-5000 autorefractor. Ophthalmic. Physiol. Opt. 24, 142 147.
    • (2004) Ophthalmic. Physiol. Opt. , vol.24 , pp. 142-147
    • Wolffsohn, J.S.1    O'Donnell, C.2    Charman, W.N.3    Gilmartin, B.4
  • 22
    • 0026652930 scopus 로고
    • The repeatability of measurement of the ocular components
    • Zadnik, K., Mutti, D. O. Adams, A. J. (1992) The repeatability of measurement of the ocular components. Invest. Ophthalmol. Vis. Sci. 33, 2325 2333.
    • (1992) Invest. Ophthalmol. Vis. Sci. , vol.33 , pp. 2325-2333
    • Zadnik, K.1    Mutti, D.O.2    Adams, A.J.3