메뉴 건너뛰기




Volumn 127, Issue 5, 2007, Pages 452-458

Paroxysmal positional vertigo after cochlear implantation

Author keywords

Canalolithiasis; Cochlear implant; Cupulolithiasis; Insertion trauma; Otolithic dysfunction; Vestibular disturbance

Indexed keywords

ADULT; AGED; BENIGN PAROXYSMAL POSITIONAL VERTIGO; CASE REPORT; COCHLEA PROSTHESIS; ELECTRONYSTAGMOGRAPHY; FEMALE; HUMAN; INCIDENCE; INNER EAR DISEASE; MALE; PEROPERATIVE COMPLICATION; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; RECIPIENT; RECURRENT DISEASE; RELAPSE; REVIEW; SPEECH; SURGICAL TECHNIQUE;

EID: 34247372648     PISSN: 00016489     EISSN: 16512553     Source Type: Journal    
DOI: 10.1080/00016480600951442     Document Type: Review
Times cited : (12)

References (25)
  • 1
    • 0029061290 scopus 로고
    • Vestibular effects associated with implantation of a multiple channel cochlear prosthesis
    • Brey RH, Facer GW, Trine MB, Lynn SG, Peterson AM, Suman VJ. Vestibular effects associated with implantation of a multiple channel cochlear prosthesis. Am J Otol 1995;16:424-30.
    • (1995) Am J Otol , vol.16 , pp. 424-430
    • Brey, R.H.1    Facer, G.W.2    Trine, M.B.3    Lynn, S.G.4    Peterson, A.M.5    Suman, V.J.6
  • 2
    • 0031801925 scopus 로고    scopus 로고
    • Influence of the multichannel cochlear implant on vestibular function
    • Ito J. Influence of the multichannel cochlear implant on vestibular function. Otolaryngol Head Neck Surg 1998;118:900-2.
    • (1998) Otolaryngol Head Neck Surg , vol.118 , pp. 900-902
    • Ito, J.1
  • 6
    • 0032707804 scopus 로고    scopus 로고
    • Benign paroxysmal positional vertigo
    • Furmann JM, Cass SP. Benign paroxysmal positional vertigo. N Engl J Med 1999;341:159-60.
    • (1999) N Engl J Med , vol.341 , pp. 159-160
    • Furmann, J.M.1    Cass, S.P.2
  • 7
    • 0032700882 scopus 로고    scopus 로고
    • An unusual complication of cochlear implant: Benign paroxysmal positional vertigo
    • Di Girolamo S, Fetoni AR, Di Nardo W, Paludetti G. An unusual complication of cochlear implant: benign paroxysmal positional vertigo. J Laryngol Otol 1999;113:922-3.
    • (1999) J Laryngol Otol , vol.113 , pp. 922-923
    • Di Girolamo, S.1    Fetoni, A.R.2    Di Nardo, W.3    Paludetti, G.4
  • 8
    • 4043056685 scopus 로고    scopus 로고
    • Interobserver agreement of coiling of Med-El cochlear implant: Plain X-ray studies
    • Todd NW, Ball TI. Interobserver agreement of coiling of Med-El cochlear implant: plain X-ray studies. Otol Neurotol 2004;25:271-4.
    • (2004) Otol Neurotol , vol.25 , pp. 271-274
    • Todd, N.W.1    Ball, T.I.2
  • 9
    • 23344447785 scopus 로고    scopus 로고
    • A model for cochlear implant electrode insertion and force evaluation: Results with a new electrode design and insertion
    • Roland JT Jr. A model for cochlear implant electrode insertion and force evaluation: results with a new electrode design and insertion. Laryngoscope 2005;115:1325-39.
    • (2005) Laryngoscope , vol.115 , pp. 1325-1339
    • Roland Jr., J.T.1
  • 11
    • 0020264424 scopus 로고
    • Effects of the single-electrode cochlear implant on the vestibular system of the profoundly deaf adults
    • Eisenberg LS, Nelson JR, House WF. Effects of the single-electrode cochlear implant on the vestibular system of the profoundly deaf adults. Ann Otol Rhinol Laryngol 1982;91:47-54.
    • (1982) Ann Otol Rhinol Laryngol , vol.91 , pp. 47-54
    • Eisenberg, L.S.1    Nelson, J.R.2    House, W.F.3
  • 14
    • 22644440702 scopus 로고    scopus 로고
    • The vestibulo-ocular reflex response to head impulses rarely decreases after cochlear implantation
    • Migliaccio AA, Della Santina CC, Carey JP, Niparko JK, Minor LB. The vestibulo-ocular reflex response to head impulses rarely decreases after cochlear implantation. Otol Neurotol 2005;26:655-60.
    • (2005) Otol Neurotol , vol.26 , pp. 655-660
    • Migliaccio, A.A.1    Della Santina, C.C.2    Carey, J.P.3    Niparko, J.K.4    Minor, L.B.5
  • 16
    • 11844254449 scopus 로고    scopus 로고
    • Disequilibrium after cochlear implantation caused by a perilymph fistula
    • Kusuma S, Liou S, Haynes DS. Disequilibrium after cochlear implantation caused by a perilymph fistula. Laryngoscope 2005;115:25-6.
    • (2005) Laryngoscope , vol.115 , pp. 25-26
    • Kusuma, S.1    Liou, S.2    Haynes, D.S.3
  • 17
    • 4544238359 scopus 로고    scopus 로고
    • Labyrinth dysfunction 8 months after cochlear implantation: A case report
    • Hempel JM, Jäger L, Baumann U, Krause E, Rasp G. Labyrinth dysfunction 8 months after cochlear implantation: a case report. Otol Neurotol 2004;25:727-9.
    • (2004) Otol Neurotol , vol.25 , pp. 727-729
    • Hempel, J.M.1    Jäger, L.2    Baumann, U.3    Krause, E.4    Rasp, G.5
  • 18
    • 0029093307 scopus 로고
    • Postimplantation Meniere's syndrome with fluctuant electrical thresholds
    • Graham SS, Dickins JRE. Postimplantation Meniere's syndrome with fluctuant electrical thresholds. Ann Otol Rhinol Laryngol 1995;104(Suppl 166):412-4.
    • (1995) Ann Otol Rhinol Laryngol , vol.104 , Issue.SUPPL. 166 , pp. 412-414
    • Graham, S.S.1    Dickins, J.R.E.2
  • 20
  • 22
    • 28144436754 scopus 로고    scopus 로고
    • Vertigo and imbalance in children: A retrospective study in a Helsinki University otorhinolaryngology clinic
    • Riina N, Ilmari P, Kentala E. Vertigo and imbalance in children: a retrospective study in a Helsinki University otorhinolaryngology clinic. Arch Otolaryngol Head Neck Surg 2005;131:996-1000.
    • (2005) Arch Otolaryngol Head Neck Surg , vol.131 , pp. 996-1000
    • Riina, N.1    Ilmari, P.2    Kentala, E.3
  • 23
    • 0030920561 scopus 로고    scopus 로고
    • Benign paroxysmal positional vertigo
    • Hughes AC, Proctor L. Benign paroxysmal positional vertigo. Laryngoscope 1997;107:607-13.
    • (1997) Laryngoscope , vol.107 , pp. 607-613
    • Hughes, A.C.1    Proctor, L.2
  • 24
    • 0023694301 scopus 로고
    • The histopathology of the human temporal bone and auditory central nervous system following cochlear implantation in a patient. Correlation with psychophysics and speech perception results
    • Clark GM, Shepherd RK, Franz BK, Dowell RC, Tong YC, Blamey PJ, et al. The histopathology of the human temporal bone and auditory central nervous system following cochlear implantation in a patient. Correlation with psychophysics and speech perception results. Acta Otolaryngol Suppl 1988;448:1-65.
    • (1988) Acta Otolaryngol Suppl , vol.448 , pp. 1-65
    • Clark, G.M.1    Shepherd, R.K.2    Franz, B.K.3    Dowell, R.C.4    Tong, Y.C.5    Blamey, P.J.6
  • 25
    • 29444443812 scopus 로고    scopus 로고
    • Histopathology of the peripheral vestibular system after cochlear implantation in the human
    • Handzel O, Burgess BJ, Nadol JB Jr. Histopathology of the peripheral vestibular system after cochlear implantation in the human. Otol Neurotol 2005;27:57-64.
    • (2005) Otol Neurotol , vol.27 , pp. 57-64
    • Handzel, O.1    Burgess, B.J.2    Nadol Jr., J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.